ELECTROMAGNETISM, OPTICS, ACOUSTICS, HEAT TRANSFER, CLASSICAL MECHANICS, AND FLUID DYNAMICS

Polycapillary X-ray lens for the secondary focusing Beijing synchrotron radiation source

, , , , , and

2013 Chinese Physical Society and IOP Publishing Ltd
, , Citation Li Yu-De et al 2013 Chinese Phys. B 22 044103 DOI 10.1088/1674-1056/22/4/044103

1674-1056/22/4/044103

Abstract

According to intensity distribution of the synchrotron radiation source focused by a toroidal mirror at the Beijing synchrotron radiation biological macromolecule station, theoretical modeling of the Beijing synchrotron radiation source is developed for capillary optics. Using this theoretical modeling, the influences of the configuration curve of the polycapillary X-ray lens on transmission efficiency and working distance are analyzed. The experimental results of the transmission efficiency and working distance at the biological macromolecule station are in good agreement with the theoretical results.

Export citation and abstract BibTeX RIS