Primary Investigation into the Laser Triggering Multi-Gap Multi-Channel Gas Switch in a Single Test Module Facility

, , , , , , and

Published under licence by IOP Publishing Ltd
, , Citation He An et al 2006 Plasma Sci. Technol. 8 602 DOI 10.1088/1009-0630/8/5/25

1009-0630/8/5/602

Abstract

A high precision laser trigger system is built up in the single test module of Primary Test Stand (PTS) facility. A fourth harmonic, with a wavelength λ of 266 nm, Q-switched Nd:YAG laser was used to trigger the 5 MV multi-gap multi-channel gas switch which was filled with high pressure SF6-N2 mixture gas. The maximum deviation and the standard deviation in the jitter time of the trigger system is ± 0.7 ns and 0.3 ns respectively. The maximum deviation and the standard deviation in the jitter time for the multi-gap multi-channel laser triggering switch is ± 2.4 ns and 1.5 ns respectively. The curve of switch delay-time versus laser energy is obtained, which is helpful for the choice of fitting laser energy. The successful test with two lasers indicated that the design of using twenty-four lasers to trigger twenty-four switches respectively is feasible in ``PTS''.

Export citation and abstract BibTeX RIS

10.1088/1009-0630/8/5/25