New distance relay compensation algorithm for double-circuit transmission line protection
New distance relay compensation algorithm for double-circuit transmission line protection
- Author(s): H. Seyedi and L. Behroozi
- DOI: 10.1049/iet-gtd.2011.0029
For access to this article, please select a purchase option:
Buy article PDF
Buy Knowledge Pack
IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.
Thank you
Your recommendation has been sent to your librarian.
- Author(s): H. Seyedi 1 and L. Behroozi 1
-
-
View affiliations
-
Affiliations:
1: Faculty of Electrical and Computer Engineering, University of Tabriz, Tabriz, Iran
-
Affiliations:
1: Faculty of Electrical and Computer Engineering, University of Tabriz, Tabriz, Iran
- Source:
Volume 5, Issue 10,
October 2011,
p.
1011 – 1018
DOI: 10.1049/iet-gtd.2011.0029 , Print ISSN 1751-8687, Online ISSN 1751-8695
A new zero sequence compensation method is proposed to correct the impedance, estimated by distance relay during the single-circuit operation of double-circuit transmission lines. In the new approach, zero sequence current of the adjacent line is not required for compensation. The new scheme is non-pilot and therefore does not require any communication link. Simulation results verify the dependability and security of the new approach. The over-reach problem, caused by mutual coupling, during far-end faults, is completely resolved by the new method.
Inspec keywords: compensation; power transmission faults; power transmission lines; power transmission protection; relay protection
Other keywords:
Subjects: Power system protection; Power transmission, distribution and supply
References
-
-
1)
- A.G. Phadke , J.S. Thorp . (2009) Computer relaying for power systems.
-
2)
- M.M. Eissa . Ground distance relay compensation based on fault resistance calculation. IEEE Trans. Power Deliv. , 4 , 1830 - 1835
-
3)
- (1987) Protective relays: application guide.
-
4)
- M.H.J. Bollen . Travelling-wave-based protection of double-circuit lines. IEE Gener., Transm. Distrib. , 1 , 37 - 47
-
5)
- W.A. Elmore . (2004) Protective relaying, theory and applications.
-
6)
- M. Garcı́a-Gracia , W. Osal , M.P. Comech . Line protection based on the differential equation algorithm using mutual coupling. Electric Power Syst. Res. J. , 566 - 573
-
7)
- A.J. Mazon , I. Zamora , J.F. Miñambres , M.A. Zorrozua , J.J. Barandiaran , K. Sagastabeitia . A new approach to fault location in two-terminal transmission lines using artificial neural networks. Electric Power Syst. Res. J. , 261 - 266
-
8)
- Aggarwal, R.K., Xuan, Q.Y., Johns, A.T., Dunn, R.W.: `Fault classification for double-circuits using self-organization mapping neural network', Proc. 32nd Universities Power Engineering Conf., September 1997.
-
9)
- F. Chunju , K.K. Li , W.L. Chan , Y. Weiyong , Z. Zhaoning . Application of wavelet fuzzy neural network in locating single line to ground fault (SLG) in distribution lines. Int. J. Electr. Power Energy Syst. , 6 , 497 - 503
-
10)
- Jain, A., Thoke, A.S., Patel, R.N.: `Double circuit transmission line fault distance location using artificial neural network', World Congress on Nature & Biologically Inspired Computing, NaBIC 2009.
-
11)
- A.G. Jongepier , L.V.D. Sluis . Adaptive distance protection of double circuit lines using artificial neural networks. IEEE Trans. Power Deliv. , 1 , 97 - 105
-
12)
- Apostolov, A., Tholomier, D., Sambasivan, S., Richards, S.: `Protection of double circuit transmission lines', 60thAnnual Conf. for Protective Relay Engineers, 2007.
-
13)
- Jain, A., Kale, V.S., Thoke, A.S.: `Application of artificial neural networks to transmission line faulty phase selection and fault distance location', paper no. 526–803, Proc. IASTED Int. Conf. on ‘Energy and Power System, 29–31 March 2006, Chiang Mai, Thailand.
-
14)
- S.A. Khaparde , N. Warke , S.H. Agarwal . An adaptive approach in distance protection using an artificial neural network. Electric Power Syst. Res. , 1 , 39 - 44
-
15)
- H. Ungrad , V. Narayan . (1970) Behavior of distance relays under earth fault conditions on double circuit lines.
-
16)
- IEEE C37: ‘113 Guide for protective relay applications to transmission lines’. 1999.
-
17)
- Skok, S., Tesnjak, S., Vrkic, N.: `Double-circuit line adaptive protection considering different operation and switching modes', IEEE PES Power Systems Conf. and Exposition, 2004.
-
18)
- Youyi, L., Xinzhou, D., Yuanzhang, S., Caunce, B.R.J., Richards, S.: `Adaptive non-communication protection of double circuit line systems', Eighth IEE Int. Conf. on Developments in Power System Protection, 2004.
-
19)
- E. Rosolowski , J. Izykowski , M.M. Saha . Fault location algorithm for use with current differential protective relays of double–circuit line. IEEE Bucharest PowerTech , 1 - 6
-
20)
- Z.Q. Bo . Adaptive non-communication protection technique for transmission lines, BO Scheme 1 – the delayed operation scheme. IEEE Trans. Power Deliv. , 1 , 85 - 91
-
21)
- Z.Q. Bo . A new non-communication protection technique for transmission lines. IEEE Trans. Power Deliv. , 4 , 1073 - 1078
-
22)
- Z.Q. Bo . Adaptive non-communication protection technique for transmission lines, BO Scheme 3 – the accelerated operation scheme. IEEE Trans. Power Deliv. , 1 , 97 - 104
-
23)
- Kang, N., Liao, Y.: `Fault location for double-circuit lines utilizing sparse voltage measurements', IEEE Power & Energy Society General Meeting, 2009.
-
24)
- A.D. Filomena , R.H. Salim , M. Resener , A.S. Bretas . Ground distance relaying with fault-resistance compensation for unbalanced systems. IEEE Trans. Power Deliv. , 3 , 1319 - 1326
-
25)
- Martin, F., Aguado, J.A., Medina, M., Munoz, J.: `Classification of faults in double circuit lines using wavelet transforms', IEEE Int. Conf. on Industrial Technology, ICIT 2008.
-
26)
- Jongepier, A.J., Sluis, L.V.D.: `Adaptive distance protection of a double circuit line using artificial neural nets', Fifth Int. Conf. on Developments in Power System Protection, 1993.
-
27)
- Z.Q. Bo . Adaptive non-communication protection technique for transmission lines, BO Scheme 2 – the instant operation scheme. IEEE Trans. Power Deliv. , 1 , 92 - 96
-
28)
- Xia, Y., Hu, G., Yin, X., Zhang, Z., Chen, W.: `The protection principle and engineering application of double-circuit transmission lines in China', 43rdInt. Universities Power Engineering Conf., UPEC 2008.
-
29)
- S.H. Horowitz , A.G. Phadke . (1992) Power system relaying.
-
30)
- H. Seyedi , M. Sanaye-Pasand . A new time-domain based power system frequency estimation algorithm. European Trans. Electr. Power
-
31)
- R.N. Mukerjee , M.F. Bin Abdullah . Under-reach correction in twin circuits without residual current input from the parallel line. IEEE Trans. Power Deliv. , 3 , 1359 - 1365
-
32)
- Sharifzadeh, M., Sanaye-Pasand, M.: `An adaptive distance scheme for double circuit line protection', 42ndInt. Universities Power Engineering Conf., UPEC 2007.
-
33)
- Bozek, M., Izykowsky, J.: `Adaptive distance protection of double-circuit lines based on differential equation fault loop model', 43rdInt. Universities Power Engineering Conf., UPEC 2008.
-
1)