New distance relay compensation algorithm for double-circuit transmission line protection

New distance relay compensation algorithm for double-circuit transmission line protection

For access to this article, please select a purchase option:

Buy article PDF
£12.50
(plus tax if applicable)
Buy Knowledge Pack
10 articles for £75.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
IET Generation, Transmission & Distribution — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

A new zero sequence compensation method is proposed to correct the impedance, estimated by distance relay during the single-circuit operation of double-circuit transmission lines. In the new approach, zero sequence current of the adjacent line is not required for compensation. The new scheme is non-pilot and therefore does not require any communication link. Simulation results verify the dependability and security of the new approach. The over-reach problem, caused by mutual coupling, during far-end faults, is completely resolved by the new method.

References

    1. 1)
      • A.G. Phadke , J.S. Thorp . (2009) Computer relaying for power systems.
    2. 2)
    3. 3)
      • (1987) Protective relays: application guide.
    4. 4)
    5. 5)
      • W.A. Elmore . (2004) Protective relaying, theory and applications.
    6. 6)
    7. 7)
    8. 8)
      • Aggarwal, R.K., Xuan, Q.Y., Johns, A.T., Dunn, R.W.: `Fault classification for double-circuits using self-organization mapping neural network', Proc. 32nd Universities Power Engineering Conf., September 1997.
    9. 9)
    10. 10)
      • Jain, A., Thoke, A.S., Patel, R.N.: `Double circuit transmission line fault distance location using artificial neural network', World Congress on Nature & Biologically Inspired Computing, NaBIC 2009.
    11. 11)
    12. 12)
      • Apostolov, A., Tholomier, D., Sambasivan, S., Richards, S.: `Protection of double circuit transmission lines', 60thAnnual Conf. for Protective Relay Engineers, 2007.
    13. 13)
      • Jain, A., Kale, V.S., Thoke, A.S.: `Application of artificial neural networks to transmission line faulty phase selection and fault distance location', paper no. 526–803, Proc. IASTED Int. Conf. on ‘Energy and Power System, 29–31 March 2006, Chiang Mai, Thailand.
    14. 14)
    15. 15)
      • H. Ungrad , V. Narayan . (1970) Behavior of distance relays under earth fault conditions on double circuit lines.
    16. 16)
      • IEEE C37: ‘113 Guide for protective relay applications to transmission lines’. 1999.
    17. 17)
      • Skok, S., Tesnjak, S., Vrkic, N.: `Double-circuit line adaptive protection considering different operation and switching modes', IEEE PES Power Systems Conf. and Exposition, 2004.
    18. 18)
      • Youyi, L., Xinzhou, D., Yuanzhang, S., Caunce, B.R.J., Richards, S.: `Adaptive non-communication protection of double circuit line systems', Eighth IEE Int. Conf. on Developments in Power System Protection, 2004.
    19. 19)
    20. 20)
    21. 21)
    22. 22)
    23. 23)
      • Kang, N., Liao, Y.: `Fault location for double-circuit lines utilizing sparse voltage measurements', IEEE Power & Energy Society General Meeting, 2009.
    24. 24)
    25. 25)
      • Martin, F., Aguado, J.A., Medina, M., Munoz, J.: `Classification of faults in double circuit lines using wavelet transforms', IEEE Int. Conf. on Industrial Technology, ICIT 2008.
    26. 26)
      • Jongepier, A.J., Sluis, L.V.D.: `Adaptive distance protection of a double circuit line using artificial neural nets', Fifth Int. Conf. on Developments in Power System Protection, 1993.
    27. 27)
    28. 28)
      • Xia, Y., Hu, G., Yin, X., Zhang, Z., Chen, W.: `The protection principle and engineering application of double-circuit transmission lines in China', 43rdInt. Universities Power Engineering Conf., UPEC 2008.
    29. 29)
      • S.H. Horowitz , A.G. Phadke . (1992) Power system relaying.
    30. 30)
    31. 31)
    32. 32)
      • Sharifzadeh, M., Sanaye-Pasand, M.: `An adaptive distance scheme for double circuit line protection', 42ndInt. Universities Power Engineering Conf., UPEC 2007.
    33. 33)
      • Bozek, M., Izykowsky, J.: `Adaptive distance protection of double-circuit lines based on differential equation fault loop model', 43rdInt. Universities Power Engineering Conf., UPEC 2008.
http://iet.metastore.ingenta.com/content/journals/10.1049/iet-gtd.2011.0029
Loading

Related content

content/journals/10.1049/iet-gtd.2011.0029
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field
Please enter a valid email address