The spatial resolution of LA-ICP-MS line scans across heterogeneous materials such as fish otoliths and zoned minerals

Abstract

LA-ICP-MS line scans can provide equivalent or better information about the distribution of elements in heterogeneous solids than discrete spot analysis; and at much reduced time and cost. However, to do so, the spatial resolution for given instrumentation and operating conditions must be known. Here, we present a quantitative and reproducible method to do this that requires line scans across a sandwich of three glasses of varying certified concentrations of trace elements. To produce sufficient counting statistics, only Ca, Sr, Rb, and Pb were analysed. Raw data (counts per second) are reduced to “instantaneous concentration” and then filtered to produce concentration profiles that contain the same dimensions as the original data. The spatial resolution is empirically determined from these profiles by using a statistical “confidence” window. Spatial resolution is controlled by the magnitude of concentration gradients, the direction of concentration shifts, and the instrumental configuration and settings such as cell size and shape, and the speed of the scan. Spatial resolution is better for increasing concentration profiles than decreasing ones by a factor of 2. The relationship between the magnitude of the concentration gradient and the spatial resolution is linear. Therefore, once the range of concentration variation is known in any target, a minimum resolution can be determined from this linear relationship. The spatial resolutions of the three elements examined are observed to be the same suggesting that element specific ablation behaviours are not a significant control on spatial resolution. A Sr concentration profile from a natural sample (fish otolith) is generated, and the resolutions from the glass sandwich are applied. For the concentrations observed and the settings and hardware used, a minimum spatial resolution of 50 µm was calculated. Concentration variations at smaller scales can be detected but not quantified.

Article information

Article type
Paper
Submitted
05 Mar 2003
Accepted
08 Jul 2003
First published
29 Jul 2003

J. Anal. At. Spectrom., 2003,18, 1231-1237

The spatial resolution of LA-ICP-MS line scans across heterogeneous materials such as fish otoliths and zoned minerals

M. Sanborn and K. Telmer, J. Anal. At. Spectrom., 2003, 18, 1231 DOI: 10.1039/B302513F

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements