Issue 4, 1996

Poly(vinyl chloride), polysulfone and sulfonated polyether-ether sulfone composite membranes for glucose and hydrogen peroxide perm-selectivity in amperometric biosensors

Abstract

Membrane materials were evaluated for use in amperometric biosensors. PVC, polysulfone (PS) and sulfonated polyether-ether sulfone–polyether sulfone (SPEES-PES) and SPEES-PES/PVC composites were solvent cast. Varying the plasticizer (isopropyl myristate) content of PS and PVC membranes enabled electrode response to hydrogen peroxide and acetaminophen to be modulated. Omission of plasticizer from PS and PVC resulted in hydrogen peroxide permeable membranes, selective against acetaminophen, ascorbate and urate (ratios [gt-or-equal] 230 : 1 in each case). SPEES–PES copolymer membranes (unplasticized) showed greater hydrogen peroxide permeability (corresponding ratios [gt-or-equal] 1430 : 1). By mixing plasticized PVC and SPEES–PES in suitable proportions, permeability ratios of hydrogen peroxide : acetaminophen were controlled. Glucose sensors using these composite membranes for H2O2 perm-selectivity demonstrated linear responses through the clinical range, and ⩽5% loss of signal on exposure to blood. A novel form of glucose oxidase based biosensor deployed a new membrane as an outer layer selective for the glucose substrate, rejecting interferents. Accordingly, a second selective layer for the enzyme reaction product (hydrogen peroxide) is not required. The new membrane is a plasticized mix of PVC and SPEES–PES polymers incorporating isopropyl myristate. Selectivity is adequate for clinical glucose measurement, and in particular acetaminophen interference is excluded in addition to ascorbate and urate, representing an advance over membranes described hitherto. A linear range of 0–20 mmol l–1 glucose confirms control of substrate diffusion sufficient to extend apparent enzyme KM, and resistance to fouling in blood is also promising for deployment in a clinical assay.

Article information

Article type
Paper

Analyst, 1996,121, 521-526

Poly(vinyl chloride), polysulfone and sulfonated polyether-ether sulfone composite membranes for glucose and hydrogen peroxide perm-selectivity in amperometric biosensors

Y. Benmakroha, I. Christie, M. Desai and P. Vadgama, Analyst, 1996, 121, 521 DOI: 10.1039/AN9962100521

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements