Issue 2, 2007

The uncertainty budget of the multi-element analysis of glasses using LA-ICP-MS

Abstract

A first attempt was made to estimate an uncertainty budget for the multi-element analysis of glasses using LA-ICP-MS, in accordance with the ‘‘Bottom-up’’ approach of the EURACHEM/CITAC-Guide.1 Analyses of NIST SRM 612, 614 and USGS glasses BCR-2G and BIR-1G were carried out using a 193 nm excimer LA-ICP-MS under routine conditions. Calibration was performed using NIST 610 with internal standardisation using Ca. The uncertainty budgets for the analytes Co, La and Th were studied. Instrumental drift and uncertainties from working values of NIST 610, as reported by Pearce et al.,2 are the dominant sources of uncertainty for a typical individual analysis of NIST 612 and BCR-2G/BIR-1G with mass contents of Co, La and Th ranging from 6 to 52 μg g−1. In contrast, the uncertainty contributions from Poisson counting statistics prevail for those of NIST 614 and BIR-1G with the three elements having a lower range between 0.029 and 0.75 μg g−1. La was an exception. Its combined uncertainties were consistently dominated by its uncertainty from the working value of NIST 610 at all mass content ranges investigated, suggesting that more accurate reference values for the analyte in NIST 610, and for all analytes with large uncertainties, are needed. Additionally, a z-score assessment was carried out using procedures similar to those used in the International Proficiency Test for Analytical Microprobe Geochemistry Laboratories. The z-scores in this study were in the range −2 < z < 2, indicating that there were no significant unsuspected influences in the analytical system. This suggests that the uncertainty budget reported here contains all the significant parameters.

Graphical abstract: The uncertainty budget of the multi-element analysis of glasses using LA-ICP-MS

Article information

Article type
Paper
Submitted
06 Jun 2006
Accepted
05 Oct 2006
First published
26 Oct 2006

J. Anal. At. Spectrom., 2007,22, 122-130

The uncertainty budget of the multi-element analysis of glasses using LA-ICP-MS

Y. Luo, S. Gao, H. P. Longerich, D. Günther, S. Wunderli, H. Yuan and X. Liu, J. Anal. At. Spectrom., 2007, 22, 122 DOI: 10.1039/B608010C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.