Introduction

The quantitative polymerase chain reaction (qPCR) was first described in the 1990s1,2 and since then it has become a popular method in a wide field of applications. The method allows for quantification of DNA over a broad range using labelled probes or fluorescence dyes (summarized by Bonneta3). With each cycle, including steps for DNA denaturation, primer annealing and DNA extension (or a combined annealing-extension step), target DNA theoretically doubles, and consequently the fluorescence signal increases. The cycle that reaches the fluorescence threshold and is used for quantification, is customarily designated Ct (threshold cycle) or Cq (quantification cycle)4.

The past two decades have witnessed the development of numerous qPCR assays with differences in their performances. Advantages proposed include low running costs, short execution times and, with probe-based assays, inherent confirmation due to sequence specificity of the probe. However, although the method is conceptually simple, the execution must not be performed careless5. It is a highly sensitive method and thus, information of assay performance is extremely relevant. Moreover, qPCR represents an enzymatic assay and therefore it should be validated per se, according to the principles of organic chemistry6,7. Thus, inherent real performance parameters should be tested in each new qPCR to display the quality of the amplification reaction in a separate process. The main performance parameters are qualitative and quantitative limits and quantitative resolution.

Conventionally qPCR validation is performed by Equivalence Partitioning Analysis based on calibration curves using the Comparative Threshold Method (Ct-method7). Calibration curves are based on standard DNA samples starting from ten DNA molecules to >1010 copies8. PCR amplification efficiency is determined from these calibration curves and is subsequently used to determine the assay performance parameter. Briefly, when the PCR product doubles during each cycle the efficiency is theoretically 100% (or 1)4. The respective correlation coefficient Rsq consequently indicates the linearity of the PCR reaction9 and the precision of the pipetting process. Thereby, a value of 1.0 indicates perfectly linear amplification. This may result in seemingly satisfying efficiencies, but a perfectly linear amplification does not reflect automatically a good efficiency. Moreover, efficiency (and Rsq) reflects only a small statistical sample (the standard DNA samples). Consequently, this method provides limited main performance parameters information.

Sufficient information of main performance parameters can be obtained by testing the qPCR using Poisson analysis which reveals quantitative and qualitative resolution in the Boundary Limit Area (<10 ITMN (initial target molecule number))6,7. Validations based on Poisson distribution have steadily grown in popularity and applicability over recent years10,11,12. Nevertheless, it operates within the range 1 to <10 ITMN of the initial DNA template. Therefore, assays comprising a detection limit above ten ITMN cannot be validated for quantitative resolution or qualitative detection boundaries using this algorithm. Furthermore, it provides information concerning qualitative resolution, but it contributes no information about the actual efficiency of the amplification reaction. However, knowing whether efficiency is constant from beginning and in accordance with the average efficiency is crucial for analyzing qPCR performance.

We present here a new Boundary Limit Analysis assay validation tool, PCR-Stop analysis, which reflects assay performance during initial qPCR cycles. It operates in the range >10 ITMN, demonstrates two-fold resolution and consequently quantitative resolution and the quantitative limit of the assay. Moreover, the evaluation of efficiency is based on actual precision of the amplification reaction independent of statistical analysis of a calibration curve. Therefore, it provides sufficient information by means of main performance parameters, especially the quantitative resolution of the method in the range of >10 ITMN. Hence, the method should be performed in combination with Poisson analysis (<10 ITMN) for thorough assay validations. Improved knowledge of assay performance thus anticipates more consistent and reliable results. Validation with the PCR-Stop analysis should be especially interesting for relative gene expression analysis, especially when using the comparative Ct method (2−ΔΔCt) where the amplification efficiency is essential and which is widely used13.

In providing exemplary data with two assays, newly generated data can be compared, thereby facilitating qPCR assay validation. One of the assays is excellent in performance while the other showed equivalent calibration curves with similar efficiencies but revealed deficiencies in PCR-Stop analysis.

Results

Intention and execution of PCR-Stop analysis

The aim of PCR-Stop analysis is to improve understanding of qPCR. Firstly, the validation method should reveal assay performance in respect of amplification efficiency during initial cycles, which are otherwise invisible. The test system should show whether there is equal DNA duplication during initial cycles corresponding to overall efficiency as displayed in the calibration curve (Ct-Method). Consequently, it permits confirmation of the calculation using the formula y = x (1 + E)n when qPCR starts with constant efficiency at the first cycle (Fig. 1; where y: copy number of the product at the end of a PCR reaction; n: cycles; E: efficiency; x: initial template copies). Further, knowing assay performance during first cycles permits Ct value prediction when one target copy is used as template (Ct1): In the case of 100% efficiency and a threshold equal to 1010 amplificates reflecting background fluorescence of unbound probe dye, one copy is equivalent to Ct1 = 37. Consequently, samples depicting Ct values significantly >37 lead to suspicion of inhibitory effects.

Figure 1
figure 1

The real amplification curve of a qPCR assay. The range of observable and significant increase in fluorescence based on amplification of the PCR product is small. The exponential phase is mostly masked by the background fluorescence of the uncoupled probe dye. Therefore PCR-Stop analysis is an indirect approach depicting events during the first amplification cycles of qPCR.

Secondly, PCR-Stop analysis is a validation tool for ranges >10 ITMN. It therefore ideally supplements Poisson analysis and reveals whether the assay has two-fold quantitative resolution. PCR-Stop analysis also discloses whether or not the polymerase reaction begins immediately with average efficiency and consequently whether or not the enzyme is completely activated. The latter point is especially useful for comparing hot start polymerases based on chemical modifications or those complexed with antibodies.

The practical execution of PCR-Stop analysis is simple. It involves six batches, each including eight samples (ideally on a strip) containing the same target DNA quantity (exceeding the Poisson distribution; >10 ITMN). These batches are subjected to PCR pre-runs with ascending numbers of amplification cycles, starting from zero to five. When the first batch is directly placed into the cooler, the other batches are each subjected to short PCR runs, representing one to five cycles of the PCR assay to be tested, and later cooled. Subsequently all batches are transferred together to the real-time PCR thermo cycler for a normal run with the entire number of cycles (Fig. 2). These batches therefore represent ongoing amplification during the first five cycles. The first batch includes the original ITMN for each sample. The other batches should analogously represent the amplification according to the cycle numbers of the respective pre-runs. For a perfect qPCR assay with 100% efficiency this would lead to exact duplication of the ITMN during amplification. Moreover, no deviation among the single samples of each batch would be observed (Table 1, Fig. 3a,e). However, realistically, these values will deviate and the overall average efficiency will be less than 100%.

Figure 2
figure 2

The experimental setup PCR-Stop analysis. Six batches each with eight samples containing the same target DNA quantity are subjected to up to five PCR pre-runs with ascending numbers of amplification cycles. Afterwards, all batches are amplified in a normal qPCR run (more details in the text).

Table 1 Copy numbers and relative standard deviations (RSD) of different assays in the PCR-Stop analysis.
Figure 3
figure 3

PCR-Stop analysis of a theoretical and two real qPCR assays. This illustrates two possibilities to determine the distribution within batches and the quantitative resolution of a theoretical optimal assay (a,e), the well performing prfA assay with 10 ITMN (b,f) and the exB with 10 (d,h) and 100 (c,g) ITMN. The ITMN are shown on the y-axis (ad). In e-h the ITMN for the 48 samples are ordered by the quantities obtained after the final qPCR run. The eight batches are indicated in different dot styles (, ∆, etc.). Not amplified samples (“No Ct”) are illustrated on the x-axis as.

PCR-Stop analysis can also be used for ITMN numbers significantly higher than the quantification limit of a given assay in order to test its quantitative resolution over a specific numerical range. In this layout the test offers the opportunity for testing assays using two-fold quantitative resolution.

Analysis of PCR-Stop experiments and its practical application

For proof of principle, we performed the PCR-Stop experiment as described in the previous section using the prfA assay, which was prior validated with Poisson analysis6,14. Furthermore, this prfA assay was established for droplet digital PCR15,16. An unpublished Salmonella enterica serovar Typhimurium assay was used as second assay, hereafter referred to as exB (example B). Conventional analysis showed that efficiency (100.6%) and Rsq (0.998) from the calibration curve were sufficient (Supplemental Fig. S1), but Poisson analysis revealed slight underquantification (Supplemental Table S2). The average initial target DNA numbers containing eight samples for performing the PCR-Stop analysis are 10 (prfA, exB) or 100 ITMN (exB), respectively.

Four criteria can be determined for analysis of PCR-Stop experiments:

  1. I.

    Duplication of the ITMN during pre-runs, demonstrating consistent efficiency of amplification during first cycles (Table 1),

  2. II.

    the relative standard deviation within the values, obtained for the eight samples of each batch, demonstrating the consistency within the assay, as well as the qualitative limit if >10 ITMN (Table 1, Fig. 3),

  3. III.

    the steady increase of values and regularity within the batches demonstrating quantitative assay resolution (Fig. 3e–h).

  4. IV.

    The final criterion, namely negative samples representing the absence of amplification thereby demonstrating the qualitative limit if >10 ITMN (Fig. 3).

(I) The amplification efficiency during first cycles is calculated from the steady increase of the average value obtained for each batch including eight samples. This value is the first criterion for the quality of a given qPCR assay. In the prfA experiment presented, the efficiency was 93.7% when calculated with the PCR-Stop experiment and showed good correlation with the 94.6% efficiency obtained from the calibration curve. On the other hand, the efficiency of the exB assay was 100.6% as calculated from the calibration curve, but 109.6% using the PCR-Stop analysis with 10 ITMN and 93% with 100 ITMN. Further, the deviation of the optimal trend line was remarkable in the case of exB at 10 ITMN (R2 = 0.6981), while satisfactory with 100 ITMN (R2 = 0.9833), which demonstrated irregularity during initial cycles (Fig. 4). However, these R2 values demonstrate the irregularity of amplification and must not be confused with those Rsq values obtained with the Ct-method (see introduction).

Figure 4
figure 4

Efficiencies during the first cycles. The PCR-Stop experiment reveals efficiencies during the first five cycles of qPCR demonstrated in the theoretical perfect assay (a), prfA assay with 10 ITMN (b) and exB assay with 10 (c) and 100 (d) ITMN.

(II) The second criterion, the relative standard deviation (RSD) of the values within the eight samples of each batch, is determined and then summarized in an average value for all batches (Table 1). A perfect assay would display 0% RSD. This value for the well performing prfA assay was approximately 20% RSD in all batches (Table 1). The RSD of exB even approached 300%. Nevertheless, the assay displays a deviation of approximately 20% RSD at higher target DNA concentrations (100 ITMN, Table 1), where the amplification reaction performs well. The lowest initial DNA target number at which this value of RSD is achieved thus represents the lower limit where good quantitative resolution for the given qPCR assay can be expected.

(III) Analysis of the third criterion displays the values of all 48 samples of the six batches summarized in graphs. For each batch in this case the values are ordered in an increasing sequence, resulting in six ascending graphs. For a perfect assay this would result in six horizontal lines with uniform distance (Fig. 3e). The graphs for the well performing prfA assay are illustrated in Fig. 3f. The graphs are evenly ascending, showing no overlap between batches. In contrast, overlaps are present in the exB assay using 10 ITMN (Fig. 3g), but with 100 ITMN the assay is again satisfactory (Fig. 3h). Figure a–d demonstrates the same values in an alternative graph revealing the performance of the quantitative resolution.

(IV) The occurrence of negative samples displaying lack of amplification during the PCR run indicate the qualitative detection limit of the given PCR assay, at the target DNA molecule number which was tested. This fourth criterion is significant if negative results accumulate and those samples are therefore identified as non-outliers. In this case the other three criteria will also display distinct deviations. In this case the experiment should be executed once more using a higher initial DNA quantity for determination of the quantitative limit and resolution. In case of the exB assay, regularly (in almost all batches at least one, Fig. 3) negative samples were present with 10 ITMN. This failure is in accordance with the other criteria which demonstrated deviating efficiency, high relative standard deviation and crossing lines in the respective graph of the exB assay.

Discussion

Since the implementation of qPCR, numerous assays have been developed and are now used for a wide range of applications. However, it is frequently neglected that these enzymatic assays must be validated per se. Therefore, and in addition to the Poisson analysis, which covers the range <10 ITMN6, we developed PCR-Stop analysis, a method for assay validation covering >10 ITMN. This method enables: (1) assessment as to how an assay performs during the very first cycles, (2) quantitative resolution of the assay in the two-fold range, (3) determination of the lower limit of the reproduction/replication of a two-fold pattern, therefore determining the quantitative limit of the assay, (4) determination of the qualitative limit of detection if the amplification fails in a significant number of samples, and (5) calculation of the efficiency of the amplification reaction during the first cycles using the average results of several batches.

In 2004 Nogva and Rudi17 concluded that efficiency is lower during starting cycles. In contrast, we have been able to show with PCR-Stop analysis that the prfA assay already starts with its average efficiency. Results also demonstrate that the polymerase (in this special case Platinum Taq complexed with an antibody for the hot start property) is from the beginning active and completely functional. Interestingly, the exB assay also starts with a similar efficiency as the average efficiency from the calibration curve but the amplification is very irregular demonstrated by the low precision (R2) when only 10 ITMN were used.

Using the exB assay, we demonstrated that precise standard curves originating from serial dilutions with satisfactory efficiencies and Rsq values do not sufficiently displaying real assay performance. Despite 100.6% efficiency and an Rsq of 0.998, the PCR-Stop analysis for the exB assay revealed insufficient resolution in the boundary limit area. Therefore, this assay is not reliable for quantification in the ranges <100 ITMN. In practice, the obtained knowledge prevents misinterpretations of results in lower ranges.

qPCRs are now familiar in many applications with different emphases. For gene expression studies, which should also detect small differences (even lower than two-fold, e.g.18) qPCR is considered the gold standard19 needing normalization steps. However, the best normalization using proper reference genes20 and open-access tools for analysis19 etc., do not help when the resolution of the assay is not sufficient for the scientific question. The PCR-Stop analysis, together with Poisson experiment, reveals the real detection limit as well as the quantitative resolution of a qPCR assay. We therefore anticipate that these methods should be very helpful for such applications.

As also Kralik and Ricchi21 emphasised, appropriate validation improves qPCR quality. Consequently, we encourage other scientists to validate their assays with both the Poisson experiment and PCR-Stop analysis. Failing or performing poorly those demonstrate the limits of assays and reveal in which ranges assays are trustful and can be applied. These validations can thus assist assessment of qPCR results, avoid misinterpretations and achieve increased confidence with qPCR applications. The MIQE (Minimum Information for Publication of Quantitative Real-Time PCR Experiments) guidelines aim also at “more reliable and unequivocal interpretation of qPCR results”4 and therefore, the PCR-Stop analysis is in line with the guidelines. The information PCR-Stops analysis provides are thereby not considered and are thus are supplementing the category assay performance which includes efficiency, precision, etc.

Methods

DNA extraction and quantification

One ml of a L. monocytogenes (strain EGDe) or Salmonella enterica serovar Typhimurium (both part of the collection of bacterial strains at the Institute of Milk Hygiene, University of Veterinary Medicine, Vienna) overnight culture was used for DNA isolation using the NucleoSpin tissue kit (Macherey Nagel, Düren, Germany) following protocol instructions for Gram-positive or Gram-negative bacteria, respectively. The DNA was eluted twice with 50 μlddH2O (70 °C). The DNA concentration was measured with the Qubit ds Broad Range Kit (Fisher Scientific, Vienna, Austria). The copy number of the single-copy prfA gene was calculated using the molecular weight (1 ng of DNA equals 3.1 × 105 copies of the genome of L. monocytogenes, 1 ng of DNA equals 1.9 × 105 copies of the genome of Salmonella enterica serovar Typhimurium).

qPCR

Real-time PCRs were performed as previously described14 in an Mx3000p real-time PCR thermocycler (Stratagene, CA, USA) and were analyzed using MxPro Software. One qPCR reaction (25 μl) contained 3.5 mM MgCl2, 12.5 pmol of each primer (prfA_fwd: 5′-GAT ACA GAA ACA TCG GTT GGC-3′; prfA_rev: 5′-GTG TAA TCT TGA TGC CAT CAG G-3′, Eurofins, Ebersberg, Germany), 6.25 pmol of each probe (prfA-probe: 5′-FAM-CAG GAT TAA AAG TTG ACC GCA-MGB-3′, Fisher Scientific, Vienna, Austria), 5 nmol each of dATP, dTTP, dGPT, and dCTP, 2.5 μl of 10× reaction buffer, 1.5 U of Platinum Taq DNA polymerase (Fisher Scientific, Vienna, Austria) and 5 μl template DNA. prfA qPCR was carried out with initial denaturation at 94 °C for 2 min following amplification in 45 cycles at 94 °C for 15 s, and 64 °C for 1 min. For exB qPCR, after initial denaturation at 95 °C for 5 min, amplification was performed in 50 cycles, at 95 °C for 5 s, and 60 °C for 1 min.

PCR-Stop

After the pre-runs (according to the description in the text and in Table 2), the reactions were stored at 4 °C and qPCR was performed as described immediately after all pre-runs were finished.

Table 2 Pre-runs.