Introduction

Evacuation of bowel contents is highly regulated and requires coordinated function of the colon, rectum and anus1. Dysfunction of this unit can lead to faecal incontinence and/or symptoms of an evacuation disorder and can have a devastating effect on quality of life2. In North America, between 7% and 18% of community-dwelling adults report faecal incontinence3,4, and 12–19% of the population report evacuation disorders5 with an age-adjusted and sex-adjusted incidence approximately threefold greater than that of Crohn's disease6. Because the underlying aetiology and pathophysiology of faecal incontinence and evacuation disorders are multifactorial, reliance on symptoms alone to guide therapy is inadequate7.

The primary approach to a patient presenting for the first time with faecal incontinence or constipation with difficult defecation should be to exclude serious underlying pathology (such as colorectal malignancy and IBD)8. In patients with symptoms refractory to first-line therapies such as lifestyle modification and optimization of stool consistency, it is justifiable to proceed with evaluation of anorectal structure, motor and sensory function9,10. The selection of appropriate investigations is often guided by the clinical history and examination. Such an evaluation should focus on determining the duration, type and severity of the patient's symptoms as well as identification of risk factors for symptom onset11. Epidemiological studies have identified a number of such risk factors, including increasing age, elevated BMI and presence of diarrhoea12,13. In women, obstetric injury is particularly relevant14,15,16 owing to the risk of damage to the pelvic floor, anal sphincters and pudendal nerves during the second stage of labour17,18. In men, iatrogenic injury to the sphincter complex secondary to anal surgery is a factor in up to 59% presenting for assessment19, and coexistent benign perianal disease (such as haemorrhoids, fistula-in-ano and radiation proctitis) is also common20. In all patients, particular attention should be paid towards symptoms of other anorectal complaints (for example, faecal incontinence in a patient presenting with constipation) as data increasingly suggest that both faecal incontinence and evacuation disorders commonly coexist21. Also, anorectal evaluation begins with a carefully performed digital rectal examination that can reveal several abnormalities, including dyssynergia, weak anal sphincters, sphincter defects and faecal impaction15,22.

No single test can fully characterize the causes of faecal incontinence and/or evacuation disorders. Instead, several tests are used to assess anorectal structure, motor and sensory function (Table 1). Data on the usefulness of these tests are conflicting, and some studies suggest that clinical examination alone is an adequate method for stratification of treatment22,23; however, there are data to suggest that quantification of function directly influences clinical decision-making24,25 and provides biomarkers that predict response to treatment26,27,28. However, despite several attempts at consensus29,30,31, there is widespread discordance in practices between institutions32. Such a disparity probably reflects factors such as access to technology, resource availability and local expertise; nevertheless, it is generally accepted that the clinical utility of tests improves when anorectal function is assessed in a structured and systematic manner33. Thus, the aim of this Consensus Statement is to provide the practising clinician with a background and framework regarding the indications, application and clinical interpretation of tests of anorectal function (Box 1). Recommendations are based on a review of the literature and discussion by members of the International Anorectal Physiology Working Group (IAPWG) under the auspices of the International Working Group for Disorders of Gastrointestinal Motility and Function, a collective of clinicians and academics with particular interest and experience in the field of anorectal function testing.

Table 1 Clinical utility of investigations of anorectal physiological function

Methods

The IAPWG steering committee (E.V.C., S.M.S., H.H., M.F. and S.S.R.) was appointed by the International Working Group for Disorders of Gastrointestinal Motility and Function. Under the guidance of the steering committee, the authors performed focused literature reviews in the following areas: anorectal manometry (ARM), anorectal neurophysiology, endoanal ultrasonography, pelvic floor ultrasonography, rectal sensory testing, balloon expulsion and defecography. Consensus was achieved through careful evaluation and discussion of available literature as well as expert agreement when recommendations lacked supporting evidence.

This Consensus Statement focuses on the tests that are widely available to the practising clinician and is divided into the following: tests of anal motor function —ARM (conventional, high-resolution (HR-ARM) and 3D high-definition (3D-HR-ARM) and neurophysiology; tests of anal structure—endoanal or pelvic floor ultrasonography; tests of rectal sensory and motor function—simple balloon distension and rectal barostat; and tests of evacuation—balloon expulsion and both barium and magnetic resonance (MR) defecography. Emerging technologies are also briefly addressed.

Tests of anal motor function

Anorectal manometry

ARM is the most widely used technique for the detection of abnormalities of sphincter function and/or rectoanal coordination15,29,31. This investigation consists of a series of pressure measurements that assess the following: involuntary function of the anal canal during rest; voluntary function during squeeze; reflex rectoanal coordination during rectal distension; and rectoanal coordination during simulated defecation ('push')7,29.

Manometric equipment can record pressure data from single points in the anal canal (termed 'conventional anal manometry') or can record and display detailed information simultaneously from the whole anal canal and distal rectum (high-resolution manometry)32,34. Although conventional anal manometry using a water-perfused system remains in clinical practice, studies suggest increased usage of the more detailed high-resolution solid-state methodology, probably in part due to the ability of this technique to more accurately characterize sphincteric function32.

Within the paradigm of high-resolution manometry, two technologies exist. HR-ARM records luminal pressures circumferentially from sensors mounted on a flexible catheter with data presented either topographically in colour plots or as an average circumferential pressure at different longitudinal levels of the anorectum34. Conversely, 3D-HR-ARM records point pressures longitudinally and radially from sensors mounted on a rigid probe with morphology represented in both 2 and 3 dimensions34.

Study indications. ARM is typically indicated for the assessment of faecal incontinence and constipation, especially if characterized by symptoms of disordered evacuation. Relative indications for ARM include assessment of functional anorectal pain, preoperative assessment of anorectal function and assessment of anorectal function in patients after obstetric injury to inform treatment decisions concerning future mode of delivery7,29.

Study performance. Although not expected to be fully diagnostic, a digital rectal examination should be performed before intubation to provide an overview of anorectal and pelvic floor structure and function to exclude faecal loading, stricture, bleeding and pain. Checking a patient's understanding of instructions such as 'squeeze' and 'push' is also helpful. Studies are typically performed in the left lateral position, and any lubricant to aid probe placement should be non-anaesthetising. The probe is then positioned ensuring that the sensors span the distal rectum to beyond the anal verge. Both conventional and high-resolution techniques can use either water-perfused or solid-state technology for data collection, and detailed description of hardware and software setup and catheter design is described elsewhere35.

A standardized protocol for ARM would improve utility of the procedure, peer acceptance, translation and dissemination of results. The protocol recommended by the IAPWG is shown in Fig. 1. This protocol consists of the following standardized measurements: rest — basal anal pressures at rest over 60 s; squeeze — anal pressure during voluntary effort; long squeeze — anal pressure during sustained voluntary effort; cough — anorectal pressure changes during cough (that is, reflex increase in rectal and anal sphincter pressures during abrupt change in intra-abdominal pressure); push — anorectal pressure changes during simulated defecation; rectoanal inhibitory reflex (RAIR) — reflex anal response to rectal distension; and rectal sensation — assessment of rectal sensitivity to distension, typically performed as part of an ARM protocol (discussed in detail later).

Figure 1: Standardized protocol for high-resolution anorectal manometry.
figure 1

RAIR, rectoanal inhibitory reflex.

PowerPoint slide

Normal reference values for many of these variables have been described in three studies using HR-ARM36,37,38 and five using 3D-HR-ARM (three adult populations39,40,41, one paediatric population42 and one series of primigravid women (first pregnancy)43. A number of similar reference values exist for conventional manometry; however, many studies use historical setups and protocols no longer in current use.

Clinical utility. A number of contemporary and historical studies have demonstrated differences in manometric findings between healthy volunteer and patient groups. Several clinically relevant features have been observed. Sphincter hypotonia (low anal resting pressure), although of low sensitivity, is associated with passive faecal incontinence44,45,46,47,48,49 (Fig. 2a), whereas sphincter hypertonia (high anal resting pressure) can be a feature of anal fissure50,51,52 or constipation53. Sphincter hypocontractility (impaired ability to voluntarily contract the anal sphincter) is associated with faecal incontinence, particularly faecal urgency45,54, and poor propulsion (impaired rectal force during push), dyssynergia (paradoxical anal sphincter contraction during push) (Fig. 2b) and pelvic floor akinesia (failure of movement of the pelvic floor)55,56,57 have been noted in patients with evacuatory dysfunction. An absent rectoanal inhibitory reflex is classically seen in Hirschsprung disease58; however, abnormal responses can also be observed in patients with faecal incontinence59 and constipation60 and after anorectal surgery61.

Figure 2: Representative high-resolution anorectal manometry traces and resultant line traces to assess anorectal function.
figure 2

a | Sphincter hypotonia in a patient with faecal incontinence, visualized in the colour contour plot as a band of pale green (20–25 mmHg) set between normal blue (5 mmHg) rectal (superiorly) and atmospheric (inferiorly) pressures. b | Dyssynergia (paradoxical anal sphincter contraction during push visualized in the colour contour plot as a band of purple (150–175 mmHg) within the anal canal and a band of yellow (50 mmHg) in a patient with evacuation disorder.

PowerPoint slide

In addition to these findings, 3D-HR-ARM has the ability to illustrate the normal asymmetry of pressures within the anal canal, with higher pressures in the posterior proximal and anterior distal regions of the sphincter. Deviation from this normal manometric anatomy can be detected on either 3D or 2D pressure plots at rest and/or squeeze and can be suggestive of pathology, although studies demonstrate only slight concordance with anal sphincter defects detected by endoanal ultrasonography62,63. Thus, pressure defects detected by 3D-HR-ARM should not be used as surrogate markers of anatomical anal sphincter defects without exercising caution.

Some evidence supports the hypothesis that pelvic floor abnormalities not previously identified by conventional ARM can be found with 3D-HR-ARM. Pilot studies suggest that this technique can measure pelvic floor descent64 and that results have a high positive predictive value (up to 100%, n = 26) for the presence of an intra-anal intussusception diagnosed by defecography65,66. These findings might be a useful indicator of the existence of pelvic floor disorders and help direct further investigation (such as defecography), especially in patients with symptoms of evacuation disorders.

Strengths and limitations. ARM is the best-established technology that provides a direct assessment of anal sphincter pressure and rectoanal coordination during simulated defecation. ARM is widely available, easy to perform and well accepted by patients. Interpretation of findings can, however, be difficult owing to the wide variability (and overlap) of manometric measurements in health and disease48,67,68,69,70. Furthermore, some studies suggest that ARM offers little additional utility over digital rectal examination for planning patient management23. Additionally, owing to the striking variability in practices between institutions32, appropriate caution should be paid to using published reference ranges unless equipment design and test protocol mirror one's own. Study setup and patient position and the presence or absence of the perception of the desire to defecate, among others, can each have a major effect on absolute values reported (affecting both false-positive and false-negative rates)71,72,73,74,75,76.

Anorectal neurophysiology

Although less commonly used in clinical practice32 (owing to the adoption of less-invasive surrogate measures of sphincter function), anal electromyography and pudendal nerve terminal motor latencies (PNTMLs) remain important tools for assessment of anorectal neurophysiological function. The branches of the pudendal nerve, which course over the pelvic floor, are vulnerable to stretch injury (during the third trimester, second stage of labour and forceps-assisted vaginal delivery), which can lead to denervation of the external anal sphincter (EAS) and faecal incontinence77,78. Owing to the complex nature of symptom generation, such assessment is always performed in conjunction with other investigations (for example, ARM) to enable accurate understanding of the pathophysiological mechanisms in play.

Recording of pelvic floor electromyography (from both the EAS and levator ani muscles) enables mapping of the EAS to identify sphincter defects, determination of striated muscle function and assessment of denervation–reinnervation potentials (indicative of neural injury)79. PNTML measurement evaluates the neuromuscular integrity between the pudendal nerve and the anal sphincter7,31,79,80.

Study indications. Neurophysiological assessment is typically indicated for the investigation of symptoms of faecal incontinence thought to be secondary to neurological injury. Relative indications for neurophysiology include symptoms of anorectal pain and characterization of complex pelvic floor disorders, especially before anorectal surgery7.

Study performance. Studies of electromyographic activity are typically performed using a needle, skin or anal plug electrode. Disposable needle electrodes are inserted into the muscle under study, and parameters are recorded to describe insertional activity, spontaneous activity, motor unit action potential morphology and recruitment during voluntary or reflex activity. For PNTML, stimulation of the pudendal nerve using a disposable bipolar electrode generates a compound muscle action potential response of the EAS80. The PNTML is the time between stimulus artefact and the onset of the compound muscle action potential response.

Clinical utility. In the striated anal musculature of patients with faecal incontinence, motor unit action potential activity, fibre density and jitter (the stability of consecutive muscle fibre discharges, reflecting the stability of terminal motor axons and neuromuscular transmission) through recording of electromyography activity have all been shown to be altered in comparison with controls79,81,82,83. For PNTML, abnormal results (prolonged latencies) are used as a surrogate marker of pudendal neuropathy and indicate either demyelination or damage to a number of fast-firing fibres84.

Strengths and limitations. Electromyography findings correlate well with sphincter pressures85 (for example, electromyographic recruitment is seen simultaneously with increased anal pressures during squeeze). Intraluminal electrodes are believed to be more accurate because they are closer to the EAS muscle and are less likely to pick up artefact from gluteal or other muscles86. Currently, the most frequent application of electromyography is as a biofeedback signal for pelvic floor retraining of EAS function in patients with faecal incontinence or constipation87,88,89, and it can be especially useful to detect paradoxical contraction or impaired relaxation of the sphincter in those with evacuation disorders89.

The clinical utility of PNTML remains controversial, as there are several test limitations: it is operator-dependent31; sensitivity and specificity are poor81,82; normal latencies can be recorded in a damaged nerve as long as some fast-conducting fibres remain90; and predictions of clinical outcomes after intervention are conflicting91. In addition, the upper limit of normal for latency is ill defined owing to substantial variability in healthy individuals7.

Tests of anal structure

Endoanal and pelvic floor ultrasonography

Endoanal ultrasonography92 is a simple and well-tolerated technique that is widely used for detecting both internal anal sphincter (IAS) and EAS defects and has substantially increased our understanding of the pathogenesis of faecal incontinence. Total pelvic floor ultrasonography (integrating endoanal, transvaginal and transperineal ultrasonography) has been used to assess pelvic organ prolapse (that is, rectocele, enterocele, intussusception and cystocele)93. Endoanal and/or pelvic MRI, although not widely available, are alternative imaging modalities available only in specialist centres93.

Study indications

Endoanal or pelvic floor ultrasonography can be used for a number of indications: to evaluate the morphological integrity of the anal sphincters in patients with faecal incontinence, particularly when surgery is being considered, and to provide information on the pelvic viscera and pelvic floor movement in patients with symptoms of an evacuation disorder as a complementary investigation to ARM and defecography94. Moreover, these approaches can be used to assess obstetric anal sphincter injuries (OASIS) after childbirth to guide early repair and/or to inform planning of subsequent deliveries95,96. Other indications exist, particularly for the staging of rectoanal neoplasms (beyond the scope of this article)97. Transperineal ultrasonography has additional indications such as assessment of urinary incontinence, voiding difficulties and pelvic organ prolapse symptoms (again considered outside the scope of this article)93.

Study performance

Endoanal ultrasonography is performed in the lateral or prone position using a rigid endoprobe (3–20 MHz), providing 360° axial views of the sphincter complex92. Modern systems enable continuous capturing of images as the probe is withdrawn through the anal canal with post hoc multiplanar 3D image reconstruction and calculation of anal sphincter volumes.

During the performance of total pelvic floor ultrasonography, the patient is placed in the dorsal lithotomy position with the hips flexed and abducted. Transperineal ultrasonography uses a curved array probe (5–9 MHz), whereas transvaginal scanning is performed using a linear array endoscopic probe (12 MHz) to obtain dynamic 2D posterior and anterior mid-sagittal views. In addition to the detection of anal sphincter defects98, this technique enables evaluation of the dynamic interaction between the pelvic floor and viscera.

Anal anatomy is complex. On endoanal ultrasonography, two discrete rings of tissue are principally visualized: the inner hypoechoic IAS and the outer hyperechoic EAS, which is caudad to the puborectalis92. Several other structures, including the subepithelial tissues and conjoined longitudinal muscle, are also imaged. In contrast to 2D ultrasonography, 3D ultrasonography can also measure the length and volume of the EAS and might be better for distinguishing EAS defects from defects in surrounding structures (that is, the transverse perinei and puboanalis muscle)99. In addition to characterization of the sphincter complex, transperineal ultrasonography provides a dynamic evaluation of the interaction of the pelvic floor viscera and musculature, comprising assessment of the posterior, central and anterior compartments100.

Clinical utility

Endoanal ultrasonography is widely available and should be considered the cornerstone for anal imaging101 (Fig. 3). The IAS can be classified as normal or pathological, with the latter defined by several factors: sphincter discontinuity (defect)48 (Fig. 3b), atrophy (identified by diffuse thinning of the sphincter (thickness ≤1 mm)102) (Fig. 3c) and/or degeneration103 or hypertrophy104,105. IAS defects and/or atrophy are appreciated to be associated with symptoms of (particularly passive) faecal incontinence45,46,48. IAS hypertrophy is primarily seen in relation to rectal intussusception and/or prolapse105,106.

Figure 3: Representative endoanal ultrasonography images.
figure 3

a | The mid-anal canal in a healthy volunteer, demonstrating an intact internal anal sphincter (IAS) (arrow) appearing hypoechoic and an intact external anal sphincter (EAS) (arrowhead) appearing hyperechoic. b | Mid-anal canal in a patient with faecal incontinence, demonstrating an IAS defect between the 1 o'clock and 5 o'clock positions (between the arrows). c | Mid-anal canal in a patient with faecal incontinence demonstrating an EAS defect, evident as an area of hypoechoic discontinuity between the 12 o'clock and 2 o'clock positions (extent of defect between dashed lines). d | Mid-anal canal in a patient with faecal incontinence demonstrating IAS atrophy (global thinning of the smooth muscle ring, which is of mixed echogenicity and is difficult to distinguish from surrounding structures; arrow). The EAS is intact.

PowerPoint slide

The EAS can be characterized as normal or pathological by sphincter discontinuity (defect) (Fig. 3d) or interruption of its fibrillar echotexture manifesting as focal thinning, scarring or atrophy92. All abnormalities can be described in cross section according to a clock face (for example, defect between 1 o'clock and 3 o'clock) and in the longitudinal plane. EAS disruption is a characteristic feature of OASIS107,108, is associated with anal hypocontractility109,110 and can be found in up to 68% of individuals presenting with symptoms of faecal incontinence (n = 200)111.

Total pelvic ultrasonography has the additional ability to enable classification of organ prolapse, describe structural and functional causes contributing to evacuation disorders93,100 and identify pubovisceral avulsion (abnormal insertion of the levator ani on the inferior pubic ramus, which is an important pathophysiological mechanism for pelvic organ prolapse and faecal incontinence)112. Although not widely available, studies have also used a 4D approach to evaluate dynamic pelvic floor movement in real time113.

Strengths and limitations

Imaging of the anal sphincters can identify defects that are often clinically unrecognized and might be amenable to surgical repair. However, whereas abnormalities of anal structure are associated with anal hypotonia and hypocontractility48, it can be challenging to interpret the clinical relevance of this finding in isolation because 10% of women have postpartum (occult) sphincter defects without any symptoms99,114.

Tests of anorectal sensory and motor function

Simple balloon distension and rectal barostat

Awareness of rectal filling is critical to normal bowel function7. Abnormal visceral sensitivity and/or biomechanical function (most commonly described by evaluation of rectal compliance) are often found in faecal incontinence and evacuation disorders7, providing the rationale for measurement of anorectal sensory and motor function via balloon distention and rectal barostat in clinical practice.

Study indications

Rectal sensory testing should be considered integral to physiological assessment of anorectal function. This testing is most commonly performed with simple balloon distension. Assessment with a rectal barostat, which is less widely available, should be considered in select patients with alterations of rectal sensation on 'standard' balloon distension and/or in whom there is a high index of suspicion of abnormal rectal compliance or capacity7,115,116. These tests enable the detection of heightened (hypersensitivity) or impaired and/or blunted (hyposensitivity) rectal sensation and/or abnormal rectal compliance or capacity (that is, 'stiff' or small (hypocompliant) or 'lax' or large (hypercompliant)).

Study performance

Rectal sensation is evaluated by assessing the perception of rectal distension7,115,116. For simple balloon distension, this test is performed by distending an elastic balloon, secured to a catheter placed within the rectum, with air (manually using a hand-held syringe or via a pump). Either ramp (continuous at 1–2 ml/s) or intermittent (phasic or stepwise) distension paradigms can be used7. During balloon inflation, individuals are instructed to report perceived sensations (first sensation, desire to defecate, urgency and maximum toleration or pain). The distending volume (or, less frequently pressure) at each of these sensory thresholds is then recorded7.

Evaluation of both motor and sensory function is performed with a computerized barostat that enables distension at a specified and precise rate, thereby minimizing observer bias and measurement error7,115. An 'oversized', non-elastic bag is used that can be regarded as infinitely compliant (in that its own properties have no influence on internal pressure) (Fig. 4a). This method is preferable to measurements using balloons, which require correction to account for their intrinsic elasticity7,114. Patients are examined in a semi-prone or lateral position to reduce pelvic hydrostatic pressure. An initial 'conditioning' distention documents the minimal distending (that is, intra-abdominal) pressure and ensures that subsequent measurements are reproducible117 (Fig. 4b). Similar to the 'simple balloon' test described earlier, sensory thresholds are recorded during ramp or phasic distensions. Intraballoon (intrarectal) volumes and pressures are recorded concurrently, enabling rectal compliance to be calculated from the derived pressure–volume curve. Rectal capacity can also be measured (defined as barostat balloon volume at a prospectively defined, supraphysiological pressure; for example, 40 mmHg118). Perceived sensations can alternatively be described using visual analogue scale scores (for example, urgency and pain) recorded on a 0–100 mm scale during distensions at set pressures (typically at 8, 16, 24, and 32 mmHg above operating pressure)119.

Figure 4: Schematic of rectal barostat setup.
figure 4

a | Typical rectal barostat setup. b | Barostat conditioning distension protocol.

PowerPoint slide

Clinical utility

The thresholds for rectal sensation can be normal, reduced (hypersensitivity) or increased (hyposensitivity) in both faecal incontinence and chronic constipation48,67,120. Demonstration of altered sensation can guide therapeutic measures aimed at normalizing sensory thresholds and relieving bowel symptoms.

Rectal hypersensitivity is a common finding in patients with symptoms of urgency and frequent defecation in diarrhoea-predominant IBS, ulcerative colitis and radiation proctitis. In IBS, this finding can be associated with increased symptom severity121. Rectal hypersensitivity is also a feature of faecal urgency and urge faecal incontinence122 and low anterior resection syndrome123. Such hypersensitivity can be related to reduced compliance, capacity or an exaggerated response to rectal distension124. Normalization of sensory thresholds in patients with hypersensitivity has been associated with positive clinical outcomes following the use of behavioural therapy, pharmacological agents and surgical interventions125,126,127; however, good outcomes are not necessarily associated with post-intervention changes in sensory parameters.

Rectal hyposensitivity (often found alongside an attenuated or absent call to stool128) is observed in 18–66% of patients with chronic constipation120, constipation-predominant IBS, faecal incontinence and evacuatory dysfunction secondary to spinal cord injury129. This finding can be 'primary' (due to direct impairment of afferent pathway function), 'secondary' (due to altered biomechanical properties; for example, megarectum) or both130. When hyposensitivity is present, the assumed mechanism is that stool is involuntarily expelled before the individual is alerted to the need to respond131. In such patients, sensory retraining has been shown to facilitate timely contraction of the external sphincter and improve continence132,133.

Demonstration of rectal hyposensitivity can indicate a severe clinical phenotype and predict a poor response to treatments such as biofeedback or bowel retraining134 and surgery with colectomy135. However, in those patients who do respond, normalization of impaired sensation is generally associated with an improvement in symptoms136,137, most notably during treatment with neuromodulation27.

Strengths and limitations

Several consensus statements and technical reviews acknowledge that evaluation of rectal sensory function has an accepted place in the clinical management of patients with anorectal disorders29,30,138,139. Nevertheless, methods for simple, elastic balloon distension are poorly standardized7. Although the use of a barostat overcomes these limitations, this technology is not widely available. However, development of a 'rapid' barostat38 could enable this approach to be performed in routine clinical practice (as a typical barostat protocol may take approximately 1 hour to complete)7. For either technique, measurements can be affected by age, the rate and pattern of distention, patient position and biomechanical and structural properties of the rectum7,140,141; hence, it is essential for results to be interpreted in the context of appropriate normative values.

Tests of evacuation

Balloon expulsion test

Inability to expel solid stool from the rectum is a key feature of patients with constipation characterized by symptoms of an evacuation disorder. The balloon expulsion test (BET) is a direct method by which to assess this function.

Study indications and performance. Balloon expulsion is a simple, office-based test that is indicated as a first-line screening investigation for assessment of the ability to evacuate. With a patient lying in the left lateral position with hips and knees flexed, a lubricated, preferably non-latex balloon attached to a plastic catheter is inserted into the rectum and inflated with 50 ml of warm water. The patient is then seated on a commode in privacy and asked to expel the balloon. The ability (or inability) to expel the balloon and the time taken for expulsion is recorded142. Although reported cut-offs for normality vary, the generally accepted limit for expulsion is between 1 and 3 min. Expulsion times longer than this can indicate disordered evacuation142,143.

Clinical utility. Although often considered to be synonymous with dyssynergic defecation, it is pertinent to note that the sensitivity and specificity of this test is variable (ranging between 68–94% and 71–81%, respectively29,142,143). Thus, BET in isolation is not sufficient to clearly diagnose an evacuation disorder144. Furthermore, agreement with other tests of evacuation is suboptimal (a prospective study of 100 patients with functional constipation published in 2016 showed only fair agreement between BET and defecography in diagnosing evacuation disorders and no agreement between BET and ARM145), and the BET provides no information about anatomical phenomena that might impair evacuation (for example, rectocele or occluding intussusception).

Nevertheless, studies do indicate that a positive result can predict response to biofeedback therapy with demonstration of a clinical response in up to 85% of patients146,147,148, although this finding is not consistent across all studies149.

Strengths and limitations. Despite good reproducibility142, test setup and study performance are poorly standardized142,144. Demographic factors have an influence, with male participants having a shorter balloon expulsion time than women and expulsion time increasing with age150.

As a simple-to-perform, office-based screening test, balloon expulsion can be considered useful for the initial assessment of patients with symptoms of evacuation disorder; however, a firm diagnosis requires confirmation with other allied tests of evacuation.

Defecography

Barium (X-ray) defecography, or evacuation proctography, is an established clinical tool for the diagnosis of evacuation disorders151. Barium defecography evaluates rectal wall morphology, pelvic floor motion and evacuation in real time152. MR defecography enables imaging of all pelvic compartments153,154,155. In comparison with other tests of evacuatory function (for example, manometry, balloon expulsion and transperineal ultrasonography), defecography provides better overall evaluation of the defecatory process and structure and/or function of the anorectum7,115.

Study indications. Primary indications for both investigations (barium and MR defecography) are to identify structural or 'functional' obstructive features associated with impaired evacuation in patients with refractory symptoms of constipation consistent with an evacuation disorder; to identify impaired evacuation and/or pelvic organ prolapse in patients with faecal incontinence21,156; and to evaluate the effects of treatment, for example, after surgical repair of anorectal or pelvic floor pathology157,158.

Study performance. Barium defecography involves fluoroscopic imaging of the anorectum during contraction of pelvic floor muscles and rectal evacuation (that is, simulated defecation) after barium paste, composed of barium sulfate, porridge oats and water, has been instilled into the rectum151,159. As rectal sensory function is critical to normal defecation159, introduction of a thick paste (approximating normal stool), to a volume individualized to a patient's desire to defecate160, might be preferable to a fixed volume of liquid barium. The patient is then seated upright on a radiolucent commode (in privacy behind a screen) during fluoroscopic screening and instructed to squeeze the anal sphincter and then expel rectal contents until evacuation is felt to be complete or the patient reports that they are unable to empty further. Rectal dimensions (length, diameter and capacity), anorectal angles, rectal wall morphological features, perineal descent and evacuatory efficacy (rate and percentage of contrast expelled) can be measured. However, the technique lacks standardization, and numerous modifications to the original method151 have been described, most notably opacification of bladder and/or vagina and/or small bowel (for example colpo-cysto-defecography), which enables concurrent visualization of cul-de-sac hernias (for example, enterocele) and other pelvic organ prolapses.

MR defecography can be performed either with the patient supine, within a closed-configuration magnet, or upright (sitting) within an open-configuration system154. However, limited availability of the latter means that the majority of studies are performed with the patient in a non-physiological supine position. The rectum is filled with a stool substitute (for example, mashed potatoes or ultrasonography gel) mixed with gadolinium if necessary.

Clinical utility. Barium defecography can identify impaired rectal evacuation and diagnose anatomical and 'functional' features that can contribute to symptoms of an evacuation disorder, such as rectocele (Fig. 5a), obstructing intussusception (Fig. 5b), rectal prolapse and megarectum, as well as dyssynergic defecation, levator ani and descending perineum syndrome152. With small bowel opacification, the effect of enterocele can be assessed. MR defecography additionally enables concurrent evaluation of bladder and vaginal vault descent and enables imaging in different orthogonal planes154.

Figure 5: Representative barium defecography images.
figure 5

a | A significant rectocele; the left panel shows a lateral view of the rectum at rest, opacified by barium neostool with the anal canal closed (arrow). The right panel clearly demonstrates a large retaining rectocele at end evacuation (extent of anterior bulging highlighted by dashed line). b | Obstructing full-thickness intussusception; the left panel shows a lateral view of the rectum at rest, with the anal canal closed (arrow). The right panel shows an image at mid-evacuation with clear invagination of the mid-rectum (between arrows) secondary to a full-thickness rectal intussusception; this is causing occlusion of the distal rectal lumen with retention of neostool proximal to this.

PowerPoint slide

Various grading systems exist for defining structural abnormalities and pelvic organ descent, both for barium161,162,163 and MRI modalities153,164, and these can be used as a basis for guiding therapy, particularly in those abnormalities deemed amenable to surgical repair. However, anatomical findings such as a small rectocele or minor intussusception are frequently found in healthy individuals159,161, and failure to recognize such variants of normal can lead to overdiagnosis. A study using barium defecography has shown that an anterior rectocele is almost always present in asymptomatic female study participants159 and that only large (>4 cm) and/or retentive rectoceles (that might be smaller) should be regarded as clinically relevant. Intra-anal (as opposed to intrarectal) intussusception159 and enterocele165 are also appreciated to be pathological.

Limited comparative studies exist comparing modalities. Barium defecography better detects intussusceptions than MR defecography, either using supine166 or upright imaging167, and is more sensitive for identifying retentive rectoceles168,169. Upright MR defecography is superior to dynamic supine MRI in imaging intussusceptions; diagnostic utility is otherwise equivalent170.

Strengths and limitations. Of the available tests used to investigate patients with symptoms of an evacuation disorder, diagnostic agreement is imperfect145,171; however, only defecography evaluates evacuation and pelvic organ structure. For this reason, consensus documents recommend defecography either as a first-line138,172 or second-line10,139 test. MRI has several advantages over barium defecography in that it lacks exposure to ionizing radiation and provides excellent soft tissue resolution of all pelvic floor compartments and supporting structures, enabling assessment of coexisting cystocele and uterovaginal prolapse154.

There remain several limitations to defecography in general. Radiation exposure for barium studies makes this test unsuitable for certain patient groups, particularly pregnant women. As with all tests of evacuatory function, defecography is not performed in response to the spontaneous desire to defecate, and embarrassment in the patient can inhibit normal behaviour, leading to overdiagnosis of impaired evacuation173; nevertheless, the diagnostic yield of functional disorders on defecography is approximately half that using other tests of evacuatory function174. A paucity of normative data is available159, particularly for MR defecography165, and a large degree of overlap in results between patients and controls limits the interpretability of results159,161.

Other technologies

A number of further technologies designed to describe anorectal function exist, some of which are established but not in routine clinical use (for example, endoanal MRI) and others that are emerging (for example, the functional lumen imaging probe). Primarily acknowledged as tools in the research setting, they provide useful insights into the mechanisms of anorectal (dys)function. Although the following list is not exhaustive, it is a brief introduction to those modalities that the Consensus Group believes to have some diagnostic capability.

Functional lumen imaging probe

The anal canal's passive ability to withstand opening pressure (that is, distensibility) is thought to have a role in the continence mechanism175. A novel device, the functional lumen imaging probe (Flip; Crospon, Ireland) measures the cross-sectional diameter of a saline-filled balloon within the anal canal as distension pressure increases. Early studies show that patients with faecal incontinence have increased distensibility of the anal canal, and this finding can be more sensitive to clinically relevant pathology than ARM176,177.

Rectal and anal motor-evoked potentials

The integrity of spinoanorectal pathways that govern anorectal neuronal function can be assessed using magnetic stimulation of the lumbar and sacral regions overlying the nerve plexi and recording the motor evoked potentials178. More specifically, motor evoked potentials can reveal either unilateral or bilateral prolonged motor-evoked potentials at the lumbar region and/or sacral region and at the rectal and/or anal sites179.

A study showed that translumbar and trans-sacral motor-evoked potentials of the rectum and anus provide better delineation of peripheral neuromuscular injury in individuals with faecal incontinence and spinal cord injury than PNTMLs180. This approach is relatively easy to perform, but it is not widely available, which is the major limitation.

Endoanal MRI

Endoanal MRI48,181,182 is a technique that enables high-resolution imaging of the EAS (with the ability to differentiate between defects, scarring and atrophy) together with visualization of surrounding structures pertinent to pelvic organ prolapse and faecal incontinence (detecting, for example, pubovisceral avulsion). Additionally, MRI muscle fibre tracking is a research technique that has enabled detailed functional assessments of the anatomy of the continence mechanism, including morphology of the EAS and puborectalis complex181.

Anorectal dysfunction

Physiological classification

No single test can fully characterize the cause(s) of faecal incontinence and evacuation disorders; instead, a range of investigations should be applied to assess anorectal structure, function and sensitivity (Table 1). We also recognize that there is no widely accepted consensus on the physiological nomenclature for the classification of anorectal disorders or the use of findings from anorectal investigations to broadly describe phenotypes.

A broad summary of the expert consensus view regarding findings of each investigation discussed earlier is presented in Table 2, with the clinical relevance classified as 'major', 'minor' and 'of questionable significance'.

Table 2 Clinical relevance of findings of investigations of anorectal physiological function

Faecal incontinence. In the context of faecal incontinence, major physiological findings with clear implications for clinical management and/or prognosis include anal hypotonia, anal hypocontractility and large sphincter defects on endoanal ultrasonography (Table 2). However, owing to the multifactorial nature of symptom generation, such abnormal physiological findings are rarely found alone and are often seen in overlapping clusters. Examples of well-recognized physiological phenotypes include anal hypotonia, IAS hypertrophy and rectoanal intussusception or full-thickness rectal prolapse in patients with symptoms of passive faecal leakage105,183,184 and anal hypocontractility, rectal hypersensitivity and rectal hypocompliance in patients with faecal urgency or incontinence or diarrhoea-predominant IBS124,185,186,187. However, although anecdotally recognized, prospective studies are required to better characterize these phenotypes, symptom clusters and disorders.

Evacuation disorders. For evacuation disorders, major findings include impaired emptying secondary to abnormal rectal structure (intussusception, prolapse or rectocele) or function (impaired propulsion or dyssynergia) and abnormalities of rectal sensitivity (in particular, rectal hyposensitivity). Again, recognized phenotypes are often characterized by more than one physiological abnormality (for example, rectal hyposensitivity with impaired evacuation secondary to enlarged rectal capacity, hypercompliance or megarectum130), and these also merit further study.

Effect of physiological evaluation on management

Epidemiological research has demonstrated that diarrhoea is the most important cause of faecal incontinence (OR 53, 95% CI 6.1–147, compared with continent controls)156 and hard stool is the most common finding in constipation188. However, symptoms of disordered defecation can be secondary to abnormalities outside the anorectum, such as colonic dysfunction189, or they can be due to obsessive–compulsive disorders and/or somatization190. Hence, physiological assessments should be considered for patients whose symptoms have not responded to stool regulation.

The clinical utility of physiological measurement has previously been confirmed in large case series24,191; however, high-quality data from prospective trials using contemporary technology with outcome data are limited. Study design is challenging owing to difficulties defining patient groups on the basis of (nonspecific) symptoms, the wide range of normal values and the variety of potential physiological findings.

The problem of overlap between health and disease is particularly pertinent in this field, as demonstrated in a blinded study of ARM in healthy individuals and patients with constipation in which 90% of healthy individuals were classified as 'abnormal' using conventional descriptors of rectoanal coordination70. Thus, test results should be interpreted with an appropriate degree of caution (particularly when planning irreversible surgical correction of a physiological or structural 'abnormality') until further robustly performed stratified medicine studies become available.

Furthermore, it should not be assumed that a single measurable physiological change directly correlates with a single symptom, as these diseases are often multifactorial. As has been demonstrated elsewhere, treatment directed at one physiological abnormality might yield poor results when the true pathological driver is not fully appreciated (for example, gastric acid suppression therapy for duodenal ulceration secondary to Helicobacter pylori infection)192.

However, the particular findings on physiological testing do currently act as a basis for clinical management (for example, anal hypocontractility with an EAS defect after obstetric injury), but there remains a need for further development of an evidence-based classification system of physiological phenotypes. This development will require serial diagnostic and outcome studies to assess the clinical utility of the system for the direction of specific behavioural, medical and surgical interventions.

Conclusions

If anorectal symptoms persist despite empirical stool regulation therapy without identification of a treatable cause, anorectal function testing can provide information that might explain the causes of faecal incontinence or evacuation disorders. This Consensus Statement has identified challenges concerning data acquisition, analysis and interpretation of results (Box 2); however, there is a high level of agreement that the evaluation of anorectal structure and function and a mechanistic understanding of anorectal pathophysiology can identify disease phenotypes and direct effective management.

Publisher's note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.