Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

  • Protocol
  • Published:

Neutral desorption sampling of biological surfaces for rapid chemical characterization by extractive electrospray ionization mass spectrometry

Abstract

Extractive electrospray ionization mass spectrometry (EESI-MS) allows the real-time, direct analysis of complex gaseous and liquid samples without any sample pretreatment under ambient conditions. By using a neutral desorption (ND) sampling gas beam to gently impact a surface, the analyte present on a surface can be efficiently sampled and then transported to the EESI source for soft ionization without any previous work-up. By separating the sampling process and the ionization process in both space and time, ion suppression effects are significantly decreased in ND-EESI-MS. Therefore, virtually any surface can be gently sampled in real time, allowing in vivo analysis of living objects while maintaining the native conditions of the sample. This greatly simplifies the procedure for the characterization of complex surfaces (e.g., plants, food, skin) and prevents potential chemical contamination, providing a unique platform for wide applications in multiple disciplines such as chemistry, biology and the life sciences. Here we present a complete description of a protocol for ND-EESI-MS for in vivo analysis of living objects, including equipment setup, reagent preparation, data acquisition and analysis steps. The data collection can be completed within a few minutes even though the time required for the entire analytical process, which largely depends on the preparation of samples and materials, takes slightly longer.

This is a preview of subscription content, access via your institution

Access options

Rent or buy this article

Prices vary by article type

from$1.95

to$39.95

Prices may be subject to local taxes which are calculated during checkout

Figure 1: Photographs of ND-EESI sampling devices.
Figure 2: Schematic diagram of atmospheric pressure ND-EESI-MS.
Figure 3: Pictures of three fish samples.
Figure 4
Figure 5: Schematic diagrams to illustrate the procedure for background subtraction.
Figure 6: Mass spectra and TIC traces of signals of frozen fish meat samples recorded by ND-EESI-MS.
Figure 7: Mass spectra recorded from the skin of a regular smoker after coffee consumption showing the presence of nicotine (m/z 163) and caffeine (m/z 195).
Figure 8: Mass spectra recorded from vegetable leaves.
Figure 9: Detection of trinitrotoluene (m/z 227) and RDX (m/z 222) by ND-EESI-MS on human skin.

Similar content being viewed by others

References

  1. Dhingra, V., Gupta, M., Andacht, T. & Fu, Z.F. New frontiers in proteomics research: a perspective. Int. J. Pharm. 299, 1–18 (2005).

    Article  CAS  Google Scholar 

  2. Kumar, S., Mohan, A. & Guleria, R. Biomarkers in cancer screening, research and detection: present and future: a review. Biomarkers 11, 385–405 (2006).

    Article  CAS  Google Scholar 

  3. Nordhoff, E., Kirpekar, F. & Roepstorff, P. Mass spectrometry of nucleic acids. Mass Spectrom. Rev. 15, 67–138 (1996).

    Article  CAS  Google Scholar 

  4. Downes, M.R. et al. Application of proteomic strategies to the identification of urinary biomarkers for prostate cancer: a review. Biomarkers 11, 406–416 (2006).

    Article  CAS  Google Scholar 

  5. Smith, L., Lind, M.J., Welham, K.J. & Cawkwell, L. Cancer proteomics and its application to discovery of therapy response markers in human cancer. Cancer 107, 232–241 (2006).

    Article  CAS  Google Scholar 

  6. Pusch, W., Flocco, M.T., Leung, S.M., Thiele, H. & Kostrzewa, M. Mass spectrometry-based clinical proteomics. Pharmacogenomics 4, 463–476 (2003).

    Article  CAS  Google Scholar 

  7. Pandor, A., Eastham, J., Beverley, C., Chilcott, J. & Paisley, S. Clinical effectiveness and cost-effectiveness of neonatal screening for inborn errors of metabolism using tandem mass spectrometry: a systematic review. Health Technol. Assess. 8, 1–13 (2004).

    Article  Google Scholar 

  8. Rubin, A.E., Tummala, S., Both, D.A., Wang, C.C. & Delaney, E.J. Emerging technologies supporting chemical process R&D and their increasing impact on productivity in the pharmaceutical industry. Chem. Rev. 106, 2794–2810 (2006).

    Article  CAS  Google Scholar 

  9. Hsieh, Y., Fukuda, E., Wingate, J. & Korfmacher, W.A. Fast mass spectrometry-based methodologies for pharmaceutical analyses. Comb. Chem. High T Scr. 9, 3–8 (2006).

    CAS  Google Scholar 

  10. Geoghegan, K.F. & Kelly, M.A. Biochemical applications of mass spectrometry in pharmaceutical drug discovery. Mass Spectrom. Rev. 24, 347–366 (2005).

    Article  CAS  Google Scholar 

  11. Corona, G. & Toffoli, G. High throughput screening of genetic polymorphisms by matrix-assisted laser desorption ionization time-of-flight mass spectrometry. Comb. Chem. High T Scr. 7, 707–725 (2004).

    CAS  Google Scholar 

  12. Gelpi, E. Contributions of liquid chromatography-mass spectrometry to 'highlights' of biomedical research. J. Chromatogr. A 1000, 567–581 (2003).

    Article  CAS  Google Scholar 

  13. Cooks, R.G., Ouyang, Z., Takats, Z. & Wiseman, J.M. Ambient mass spectrometry. Science 311, 1566–1570 (2006).

    Article  CAS  Google Scholar 

  14. Takats, Z., Wiseman, J.M., Gologan, B. & Cooks, R.G. Mass spectrometry sampling under ambient conditions with desorption electrospray ionization. Science 306, 471–473 (2004).

    Article  CAS  Google Scholar 

  15. Cody, R.B., Laramee, J.A. & Durst, H.D. Versatile new ion source for the analysis of materials in open air under ambient conditions. Anal. Chem. 77, 2297–2302 (2005).

    Article  CAS  Google Scholar 

  16. Chen, H.W. et al. Surface desorption atmospheric pressure chemical ionization mass spectrometry for direct ambient sample analysis without toxic chemical contamination. J. Mass Spectrom. 42, 1045–1056 (2007).

    Article  CAS  Google Scholar 

  17. Na, N. et al. Direct detection of explosives on solid surfaces by mass spectrometry with an ambient ion source based on dielectric barrier discharge. J. Mass Spectrom. 42, 1079–1085 (2007).

    Article  CAS  Google Scholar 

  18. Chen, H.W. et al. Instrumentation and characterization of surface desorption atmospheric pressure chemical ionization mass spectrometry. Chinese J. Anal. Chem. 35, 1233–1240 (2007).

    Article  CAS  Google Scholar 

  19. Chen, H.W., Pan, Z.Z., Talaty, N., Raftery, D. & Cooks, R.G. Combining desorption electrospray ionization mass spectrometry and nuclear magnetic resonance for differential metabolomics without sample preparation. Rapid Commun. Mass Spectrom. 20, 1577–1584 (2006).

    Article  CAS  Google Scholar 

  20. Mulligan, C.C. et al. Direct monitoring of toxic compounds in air using a portable mass spectrometer. Analyst 131, 556–567 (2006).

    Article  CAS  Google Scholar 

  21. Chen, H.W., Venter, A. & Cooks, R.G. Extractive electrospray ionization for direct analysis of undiluted urine, milk and other complex mixtures without sample preparation. Chem. Commun. 19, 2042–2044 (2006).

    Article  Google Scholar 

  22. Gu, H.W. et al. Monitoring diet effects via biofluids and their implications for metabolomics studies. Anal. Chem. 79, 89–97 (2007).

    Article  CAS  Google Scholar 

  23. Zhou, Z.Q. et al. Rapid detection of atrazine and its metabolite in raw urine by extractive electrospray ionization mass spectrometry. Metabolomics 3, 101–104 (2007).

    Article  CAS  Google Scholar 

  24. Chen, H. et al. Manipulation of charge states of biopolymer ions by atmospheric pressure ion/molecule reactions implemented in an extractive electrospray ionization source. Eur. J. Mass Spectrom. 13, 273–279 (2007).

    Article  Google Scholar 

  25. Zhou, Y.M., Ding, J.H., Zhang, X. & Chen, H.W. Ion-ion reactions for charge reduction of biopolymer at atmospheric pressure ambient. Chin. Chem. Lett. 18, 115–117 (2007).

    Article  CAS  Google Scholar 

  26. Chen, H.W., Wortmann, A., Zhang, W.H. & Zenobi, R. Rapid in vivo fingerprinting of non-volatile compounds in breath by extractive electrospray ionization quadrupole time-of-flight mass spectrometry. Angew. Chem. Int. Ed. 46, 580–583 (2007).

    Article  CAS  Google Scholar 

  27. Chen, H.W. et al. Rapid detection of explosives on human skin by neutral desorption extractive electrospray ionization mass spectrometry. J. Amer. Soc. Mass Spectrom. (in press).

  28. Chen, H.W., Wortmann, A. & Zenobi, R. Neutral desorption sampling coupled to extractive electrospray ionization mass spectrometry for rapid differentiation of biosamples by metabolomic fingerprinting. J. Mass Spectrom. 42, 1123–1135 (2007).

    Article  CAS  Google Scholar 

  29. Chen, H., Yang, S., Wortmann, A. & Zenobi, R. Neutral desorption sampling of living objects for rapid analysis by extractive electrospray ionization mass spectrometry. Angew. Chem. Int. Edit. 46, 7591–7594 (2007).

    Article  CAS  Google Scholar 

  30. Williams, J.P. & Scrivens, J.H. Coupling desorption electrospray ionization and neutral desorption/extractive electrospray ionization with a travelling-wave based ion mobility mass spectrometer for the analysis of drugs. Rapid Commun. Mass Spectrom. 22, 187–196 (2008).

    Article  CAS  Google Scholar 

Download references

Acknowledgements

We acknowledge funding from the National Natural Science Foundation of China (grant no. 205005). We also acknowledge the valuable help of Dr. Shuiping Yang and Dr. Arno Wortmann in performing some of the EESI experiments shown here, the assistance of Dr. Chunmei Li for providing the E. coli samples and helping to clean the E. coli medium, and help from Jia Hui Grace Leong with the editing.

Author information

Authors and Affiliations

Authors

Corresponding authors

Correspondence to Huanwen Chen or Renato Zenobi.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Chen, H., Zenobi, R. Neutral desorption sampling of biological surfaces for rapid chemical characterization by extractive electrospray ionization mass spectrometry. Nat Protoc 3, 1467–1475 (2008). https://doi.org/10.1038/nprot.2008.109

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1038/nprot.2008.109

This article is cited by

Comments

By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.

Search

Quick links

Nature Briefing

Sign up for the Nature Briefing newsletter — what matters in science, free to your inbox daily.

Get the most important science stories of the day, free in your inbox. Sign up for Nature Briefing