Skip to main content
Log in

Determination of total mercury in environmental and biological samples using k0-INAA, RNAA and CVAAS/AFS techniques: Advantages and disadvantages

  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

The accuracy and precision of the results obtained for total mercury in various environmental and biological samples and certified reference materials (CRMs) by various analytical methods, including k 0-instrumental neutron activation analysis (k 0-INAA), radiochemical neutron activation analysis (RNAA) and cold vapour atomic absorption (and atomic fluorescence) spectrometry (CVAAS/AFS) used in routine analysis in our laboratory, were investigated. Three natural matrix reference materials (RMs) from the International Atomic Energy Agency (IAEA), five CRMs from the Institute for Reference Materials and Measurements (IRMM), six CRMs from the National Institute of Standards and Technology (NIST) and one from the Jožef Stefan Institute (IJS) were analyzed. The results obtained show good agreement between certified or assigned values, and between the methods used, except for some data obtained by k 0-INAA in biological samples. This can be explained by losses during irradiation in semi-open systems (irradiation in plastic ampoules) and/or spectral interferences.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. B. SmodiŠ, R. JaĆimoviĆ, S. JovanoviĆ, P. Stegnar, P. VukotiĆ, Vestn. Slov. Kem. Drus., 35 (1988) 397.

    Google Scholar 

  2. F. De Corte, R. Van Sluijs, A. Simonits, J. KuČera, B. SmodiŠ, A. R. Byrne, A. De Wispelaere, D. Bossus, J. FrÁna, Z. HorÁk, R. JaĆimoviĆ, Fresenius J. Anal. Chem., 370 (2001) 38.

    Article  CAS  Google Scholar 

  3. B. Fazekas, G. MolnÁr, T. Belgya, L. Dabolczi, A. Simonits, J. Radioanal. Nucl. Chem., 215 (1997) 271.

    Article  CAS  Google Scholar 

  4. HYPERMET-PC V5.0, User's Manual, Institute of Isotopes, Budapest, Hungary, 1997.

    Google Scholar 

  5. KAYZERO/SOLCOI® for Reactor-neutron Activation Analysis (NAA) Using the k0-Standardization Method, DSM Research, Geleen, The Netherlands, Dec. 1996.

  6. L. Kosta, A. R. Byrne, Talanta, 16 (1969) 1297.

    Article  CAS  Google Scholar 

  7. M. Horvat, T. ZvonariĆ, P. Stegnar, Vestn. Slov. Kem. Drus., 33 (1986) 475.

    CAS  Google Scholar 

  8. M. Horvat, V. LupŠina, N. S. Bloom, Anal. Chim. Acta, 243 (1991) 71.

    Article  CAS  Google Scholar 

  9. M. Horvat, L. Liang, S. Azemard, V. MandiĆ, J. P. Villeneuve, M. Coquery, Fresenius J. Anal. Chem., 358 (1997) 411.

    Article  CAS  Google Scholar 

  10. A. GnamuŠ, A. R. Byrne, M. Horvat, P. Stegnar, Environ. Sci. Technol., 34 (2000) 3337.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Jaćimović, R., Horvat, M. Determination of total mercury in environmental and biological samples using k0-INAA, RNAA and CVAAS/AFS techniques: Advantages and disadvantages. Journal of Radioanalytical and Nuclear Chemistry 259, 385–390 (2004). https://doi.org/10.1023/B:JRNC.0000020905.95715.88

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/B:JRNC.0000020905.95715.88

Keywords

Navigation