Abstract
The accuracy and precision of the results obtained for total mercury in various environmental and biological samples and certified reference materials (CRMs) by various analytical methods, including k 0-instrumental neutron activation analysis (k 0-INAA), radiochemical neutron activation analysis (RNAA) and cold vapour atomic absorption (and atomic fluorescence) spectrometry (CVAAS/AFS) used in routine analysis in our laboratory, were investigated. Three natural matrix reference materials (RMs) from the International Atomic Energy Agency (IAEA), five CRMs from the Institute for Reference Materials and Measurements (IRMM), six CRMs from the National Institute of Standards and Technology (NIST) and one from the Jožef Stefan Institute (IJS) were analyzed. The results obtained show good agreement between certified or assigned values, and between the methods used, except for some data obtained by k 0-INAA in biological samples. This can be explained by losses during irradiation in semi-open systems (irradiation in plastic ampoules) and/or spectral interferences.
Similar content being viewed by others
References
B. SmodiŠ, R. JaĆimoviĆ, S. JovanoviĆ, P. Stegnar, P. VukotiĆ, Vestn. Slov. Kem. Drus., 35 (1988) 397.
F. De Corte, R. Van Sluijs, A. Simonits, J. KuČera, B. SmodiŠ, A. R. Byrne, A. De Wispelaere, D. Bossus, J. FrÁna, Z. HorÁk, R. JaĆimoviĆ, Fresenius J. Anal. Chem., 370 (2001) 38.
B. Fazekas, G. MolnÁr, T. Belgya, L. Dabolczi, A. Simonits, J. Radioanal. Nucl. Chem., 215 (1997) 271.
HYPERMET-PC V5.0, User's Manual, Institute of Isotopes, Budapest, Hungary, 1997.
KAYZERO/SOLCOI® for Reactor-neutron Activation Analysis (NAA) Using the k0-Standardization Method, DSM Research, Geleen, The Netherlands, Dec. 1996.
L. Kosta, A. R. Byrne, Talanta, 16 (1969) 1297.
M. Horvat, T. ZvonariĆ, P. Stegnar, Vestn. Slov. Kem. Drus., 33 (1986) 475.
M. Horvat, V. LupŠina, N. S. Bloom, Anal. Chim. Acta, 243 (1991) 71.
M. Horvat, L. Liang, S. Azemard, V. MandiĆ, J. P. Villeneuve, M. Coquery, Fresenius J. Anal. Chem., 358 (1997) 411.
A. GnamuŠ, A. R. Byrne, M. Horvat, P. Stegnar, Environ. Sci. Technol., 34 (2000) 3337.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Jaćimović, R., Horvat, M. Determination of total mercury in environmental and biological samples using k0-INAA, RNAA and CVAAS/AFS techniques: Advantages and disadvantages. Journal of Radioanalytical and Nuclear Chemistry 259, 385–390 (2004). https://doi.org/10.1023/B:JRNC.0000020905.95715.88
Issue Date:
DOI: https://doi.org/10.1023/B:JRNC.0000020905.95715.88