Skip to main content
Log in

Myocardial perfusion imaging using a non-contrast agent MR imaging technique

  • Published:
The International Journal of Cardiovascular Imaging Aims and scope Submit manuscript

Abstract

Introduction: A MR imaging (MRI) method has been developed to determine quantitatively myocardial perfusion (P) in the rat heart in vivo. This method has the potential to non-invasively measure cardiac perfusion without the use of a contrast agent by exploiting the endogenous contrast from flowing blood itself. Method and Results: Principle of the technique is the arterial spin labeling of endogenous water protons within the short axis imaging slice. Arterial spin labeling techniques are based on a model that uses inflow effects to relate intrinsic changes in longitudinal relaxation (T 1) to tissue perfusion. Perfusion is determined from the difference between a slice selective and a global inversion recovery experiment. Perfusion was determined at rest and during hyperemia induced by intravenous adenosine (3 mg/(kgmin)). The MR perfusion values were compared with perfusion data obtained in the same animal using the colored microspheres (MS) technique as the gold standard. The MR perfusion (mean ± SEM) was 3.3 ± 0.2 ml/min/g at rest and 4.6 ± 0.6 ml/min/g during adenosine. Perfusion values obtained by colored MS were 3.4 ± 0.2 and 4.7 ± 0.8 ml/min/g at rest and during vasodilation, respectively. Adenosine decreased mean arterial pressure (MAP) from 120 to 65 mmHg which implies a reduction of coronary resistance (CR) to about 50% of baseline. Conclusion: Our study shows that quantitative mapping of perfusion may be performed non-invasively by MRI. The MR perfusion data are in excellent correlation with data obtained by the well-established colored MS technique. Determination of perfusion reserve confirms that coronary perfusion is highly dependent on blood pressure due to changes in CR.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Rubio R, Berne RM. Regulation of coronary blood flow. Progress Cardiovasc Dis 1975; 18(2): 105-122.

    Google Scholar 

  2. Hoffman JIE. Maximal coronary flow and the concept of coronary vascular reserve. Circulation 1984; 70(2): 153-159.

    Google Scholar 

  3. Karam R, Healy BP, Wicker P. Coronary reserve is depressed in postmyocardial infarction reactive cardiac hypertrophy. Circulation 1990; 81: 238-246.

    Google Scholar 

  4. Nelissen-Vrancken HJMG, Debets JJM, Snoeckx LHEH, Daemen MJAP, Smits JFM. Time-related normalization of maximal coronary flow in isolated perfused hearts of rats with myocardial infarction. Circulation 1996; 93: 349-355.

    Google Scholar 

  5. Kalkman EdAJ, Bilgin YM, v Haren P, v Suylen R-J, Saxena PR, Schoemaker RG. Determinants of coronary reserve in rats subjected to coronary artery ligation or aortic banding. Cardiovasc Res 1996; 32: 1088-1095.

    Google Scholar 

  6. Domenech RJ, Hoffman JIE, Noble MIM, Saunders KB, Henson JR, Subijanto S. Total and regional coronary blood flow measured by radioactive microspheres in consicious and anesthetized dogs. Circ Res 1969; 25: 581-596.

    Google Scholar 

  7. Malik AB, Kaplan JE, Saba TM. Reference sample method for cardiac output and regional blood flow determination in the rat. J Appl Physiol 1976; 40: 472-475.

    Google Scholar 

  8. Kowallik P, Schulz R, Guth BD, et al. Measurement of regional myocardial blood flow with multiple colored microspheres. Circulation 1991; 83: 974-982.

    Google Scholar 

  9. Jayaweera AR, Matthew TL, Sklenar J, et al. Method for the quantification of myocardial perfusion during myocardial contrast two-dimensional echocardiography. J Am Soc Echocardiogr 1990; 3: 1557-1564.

    Google Scholar 

  10. Wu X, Ewert DL, Liu Y-H, Ritman EL. In vivo relation of intramyocardial blood volume to myocardial perfusion. Circulation 1992; 85: 730-737.

    Google Scholar 

  11. Atkinson DJ, Burstein D, Edelman RR. First-pass cardiac perfusion: evaluation with ultrafast MR imaging. Radiology 1990; 174: 757-762.

    Google Scholar 

  12. Wilke N, Kroll K, Merkle H, et al. Regional myocardial blood volume and flow: first-pass MR imaging with polylysine-Gd-DTPA. JMRI 1995; 5: 227-237.

    Google Scholar 

  13. Weisskoff RM, Chesler D, Boxerman JL, Rosen BR. Pitfalls in MR measurement of tissue blood flow with intravascular tracers: which mean transit time? Magn Res Med 1993; 29: 553-558.

    Google Scholar 

  14. Chesler DA, Kwong KK. An intuitive guide to the T 1 based perfusion model. Intern J Imaging Syst Technol 1995; 6: 171-174.

    Google Scholar 

  15. Kwong KK, Chesler DA, Weisskoff RM, et al. MR perfusion studies with T 1 weighted echo planar imaging. Magn Res Med 1995; 34: 878-887.

    Google Scholar 

  16. Schwarzbauer C, Morrissey SP, Haase A. Quantitative magnetic resonance imaging of perfusion using magnetic labeling of water proton spins within the detection slice. Magn Res Med 1996; 35: 540-546.

    Google Scholar 

  17. Williams DS, Zhang W, Koretsky AP, Adler S. Perfusion imaging of the rat kidney with MR. Radiology 1994; 190: 813-818.

    Google Scholar 

  18. Roberts DA, Detre JA, Bolinger L, et al. Renal perfusion in humans: MR imaging with spin tagging of arterial water. Radiology 1995; 196: 281-286.

    Google Scholar 

  19. Poole DC, Batra S, Mathieu-Costello O, Rakusan K. Capillary geometrical changes with fiber shortening in rat myocardium. Circ Res 1992; 70: 697-706.

    Google Scholar 

  20. Kanatsuka H, Lamping KG, Eastham CL, Dellsperger KC, Marcus ML. Comparison of the effect of increased myocardial oxygen consumption and adenosine on the coronary microvascular resistance. Circ Res 1998; 65: 1296-1305.

    Google Scholar 

  21. Chilian WM, Layne SM. Coronary microvascular responses to reductions in perfusion pressure. Circ Res 1990; 66: 1227-1238.

    Google Scholar 

  22. Hiller K-H, Adami P, Voll S,et al. In vivo colored microspheres in the isolated rat heart for use in NMR. J Mol Cell Cardiol 1996; 28: 571-577.

    Google Scholar 

  23. Bauer WR, Hiller K-H, Roder F, Rommel E, Ertl G, Haase A. Magnetization exchange in capillaries by microcirculation affects diffusion-controlled spin-relaxation: a model which describes the effect of perfusion on relaxation enhancement by intravascular contrast agents. Magn Res Med 1996; 35: 43-55.

    Google Scholar 

  24. Belle V, Kahler E, Waller C, et al. In vivo quantitative mapping of cardiac perfusion in rats using a noninvasive MR spin-labeling method. JMRI 1998; 8: 1240-1245.

    Google Scholar 

  25. Bauer WR, Roder F, Hiller K-H, et al. The effect of perfusion on T 1 after slice selective spin inversion in the isolated cardioplegic rat heart: measurement of a lower bound of intracapillary-extravascular water exchange rate. Magn Res Med 1997; 38: 917-923.

    Google Scholar 

  26. Deetjen P. Wasser-und Elektrolythaushalt. In: Schmidt RF, Thews G (eds), Physiologie des Menschen. Berlin: Springer-Verlag, 1990; 808-818.

    Google Scholar 

  27. Rommel E, Hu K, Bauer WR, Ertl G, Haase A. ECG-triggered Snapshot FLASH T 1 studies of rats hearts in vivo. MAGMA 1994; (2): 224.

  28. Hiller K-H, Roder F, Adami P, et al. Studies of microcirculation by colored microspheres and NMR-microscopy in isolated rat heart: effect of ischemia, endothelin-1 and endothelin-1 antagonist BQ 610. J Mol Cel Cardiol 1997; 29: 3115-3122.

    Google Scholar 

  29. Deichmann R, Haase A. Quantification of T 1 values by Snapshot-FLASH NMR imaging. J Magn Reson 1992; 96: 608-612.

    Google Scholar 

  30. Nekolla S, Gneiting T, Syha J, Deichmann R, Haase A. T 1 maps by k-space reduced snapshot-FLASH MRI. J Comp Ass Tomogr 1992; 16(2): 327-332.

    Google Scholar 

  31. Rakusan K. Quantitative morphology of capillaries of the heart. Meth Achievm Exp Path 1971; 5: 272-286.

    Google Scholar 

  32. Judd RM, Levy BI. Effects of barium-induced cardiac contraction on large and small-vessel intramyocardial blood volume. Circ Res 1991; 68: 217-225.

    Google Scholar 

  33. Anversa P, Beghi C, Kikkawa Y, Olivetti G. Myocardial infarction in rats. Infarct size, myocyte hypertrophy, and capillary growth. Circ Res 1986; 58: 26-37.

    Google Scholar 

  34. Eriksson E, Myrhage R. Microvascular dimensions and blood flow in skeletal muscle. Acta Physiol Scand 1972; 86: 211-222.

    Google Scholar 

  35. Bassingthwaighte JB. Microvascular considerations in NMR flow imaging. Magn Res Med 1990; 14: 172-178.

    Google Scholar 

  36. Zierhut W, Rudin M, Robertson E, et al. Time course of spirapril-induced structural and functional changes after myocardial infarction in rats followed with magnetic resonance imaging. J Cardiovasc Pharmacol 1993; 21: 937-946.

    Google Scholar 

  37. Gregg DE, Fisher LC. Blood supply to the heart. In: Hamilton WF, Dow F (eds), Handbook of Physiology, Circulation Vol. II. Washington, DC: American Physiological Society, 1963: 424-429.

    Google Scholar 

  38. Vexler VS, Berthèzene Y, Wolfe CL, et al. Magnetic resonance imaging demonstration of pharmacologic-induced myocardial vasodilatation using a macromolecular gadolinium contrast agent. Invest Radiol 1992; 27: 935-941.

    Google Scholar 

  39. Kanatsuka H, Lamping KG, Eastham CL, Dellsperger KC, Marcus ML. Comparison of the effect of increased myocardial oxygen consumption and adenosine on the coronary microvascular resistance. Circ Res 1998; 65: 1296-1305.

    Google Scholar 

  40. Crystal GJ, Downey HF, Bashour FA. Small vessel blood volume and total coronary blood volume during intracoronary adenosine. Am J Physiol 1981; 41: H194-H201.

    Google Scholar 

  41. Strauer BE. The concept of coronary flow reserve. J Cardiovasc Pharmacol 1992; 19(5): 67S-80S.

    Google Scholar 

  42. Ertl G, Simm F, Wichmann J, Fuchs M, Lochner W. The dependence of coronary collateral blood flow on regional vascular resistances. Naunyn-Schmiedeberg's Arch Pharmacol 1979; 308: 265-272.

    Google Scholar 

  43. Poncelet BP, Koelling TM, Schmidt CJ, et al. Measurement of human myocardial perfusion by double-gated flow alternating inversion recovery EPI. Magn Res Med 1999; 41: 510-519.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Waller, C., Hiller, KH., Voll, S. et al. Myocardial perfusion imaging using a non-contrast agent MR imaging technique. Int J Cardiovasc Imaging 17, 123–132 (2001). https://doi.org/10.1023/A:1010603217785

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1010603217785

Navigation