Assessment of capacity design of columns in steel moment resisting frames with viscous dampers

https://doi.org/10.1016/j.soildyn.2016.06.006Get rights and content

Highlights

  • The capacity design of columns of steel MRFs with viscous dampers is evaluated.

  • Tall steel MRFs with viscous dampers experience column plastic hinges.

  • Stricter capacity design of columns for MRFs with viscous dampers is not justified.

Abstract

Previous research showed that steel moment-resisting frames (MRFs) with viscous dampers may experience column plastic hinges under strong earthquakes and highlighted the need to further assess the efficiency of capacity design rules. To partially address this need, three alternatives of a prototype building having five, 10 and 20 stories are designed according to Eurocode 8 using either steel MRFs or steel MRFs with dampers. Incremental dynamic analysis (IDA) is conducted for all MRFs and their collapse resistance and plastic mechanism is evaluated. The results show that steel MRFs with dampers are prone to column plastic hinging in comparison to steel MRFs. The steel MRFs with dampers are then iteratively re-designed with stricter capacity design rules to achieve a plastic mechanism that is approximately similar to that of steel MRFs. The performance of these re-designed steel MRFs with dampers indicates, that overall, enforcement of stricter capacity design rules for columns is not justified neither from a collapse resistance or a reparability perspective.

Introduction

Conventional seismic-resistant steel structures may experience significant structural and non-structural damage under strong earthquakes due to large story drifts and cyclic plastic deformations in main structural members [1]. Damage results in socio-economic losses (e.g. large repair costs and loss of building occupancy), which are no longer acceptable by modern societies aiming to achieve high levels of earthquake resilience. Therefore, there is an urgent need for codification and widespread implementation of resilient seismic-resistant steel structures that are less vulnerable and easier to repair after strong earthquakes [2].

A well-known class of resilient steel structures is the steel moment-resisting frames (MRFs) with passive dampers [3]. Among the different types of dampers, fluid viscous ones have been extensively studied as they have major advantages including large energy dissipation capacity and peak forces that are out of phase with the peak story drifts of elastic or mildly inelastic frames [4]. Viscous dampers consist of a hollow cylinder fully filled with a fluid and a steel piston with a rod and a piston head. Based on previous dynamic tests, the hysteretic behavior of viscous dampers can be described by [4]:FD=C|v|αsgn(v)where FD is the damper force output, C is the damping coefficient, v is the velocity across the damper, a is the velocity exponent, and sgn is the signum function. Viscous dampers are typically inserted in steel MRFs by using strong supporting braces, which are designed to be stiff enough so that story drift produces damper deformation rather than brace deformation [3].

A parametric study on the seismic response of yielding single-degree-of-freedom (SDOF) systems evaluated the effect of supplemental viscous damping on peak displacements, residual displacements and absolute accelerations [5]. Researchers proposed predictive formulae for the peak relative velocity of yielding SDOF systems for different levels of supplemental viscous damping [6], while others showed that the nonlinearity of the viscous damper influences the probabilistic seismic response of linear elastic SDOF systems [7], [8]. Research efforts quantified the benefits of using viscous dampers for reducing damage in non-structural components of building structures [9], [10]. Notable experimental studies that validated the superior seismic performance of steel MRFs with viscous dampers include the full-scale shaking table tests conducted by Kasai et al. [11] and the large-scale real-time hybrid simulations conducted by Dong et al. [12].

ASCE 7-10 provides a detailed design procedure for buildings with passive dampers within the framework of the traditional response spectrum and equivalent lateral force methods of analysis [13]. These procedures are iterative and their basis is the use of an equivalent highly damped linear elastic SDOF system, which serves as a substitute of the real yielding frame with dampers. The use of the equivalent linear SDOF system allows the damping system (i.e., the frame that includes the viscous dampers, and their supporting braces and connections) to be designed for three different loading conditions, i.e. those associated with the maximum displacement, maximum velocity and maximum acceleration. The effectiveness of the ASCE 7-10 procedure has been extensively evaluated with seismic simulations on steel MRFs with viscous dampers under the design basis and maximum considered earthquake (DBE and MCE, respectively) intensities in [14], [15]. Guo and Christopoulos [16] proposed an alternative design procedure for multiple target performance objectives utilizing a graphic tool to estimate peak response parameters of yielding structures with passive dampers either by nonlinear response history analyses or by an equivalent linearization procedure.

The author and co-workers explored the design requirements (base shear strength, design drift) which guarantee that a steel MRF with viscous dampers will have seismic collapse resistance similar or higher than that of a special steel MRF [17]. Moreover, they showed that the collapse mode of steel MRFs with viscous dampers is generally identical to that of a special steel MRF, i.e. a sway mechanism with plastic hinges in beams and in column bases. In some cases though, the collapse mode was a combination of plastic hinges in beams and plastic hinges in columns of different stories. Interestingly, a collapse mode characterized by a distinctive soft-story mechanism (i.e. formation of plastic hinges at the top and bottom of columns for a particular story) was also observed for few ground motions (e.g. three out of 44 records). The reason of these unique (for a steel MRF) collapse modes is the high viscous dampers forces that impose high axial force demands to the columns. The aforementioned study, which was based only on a 5-storey building, highlights the need for further research on capacity design of columns and its effect on the collapse resistance of steel MRFs with viscous dampers. Moreover, the seismic intensity beyond which plastic hinges are developed in columns of steel MRFs with viscous dampers should be evaluated since column plastic hinges lead to non-reparable damage, while repair of damage in beam plastic hinges can be addressed by using special bolted fuses at the beam ends [18], [19].

This paper aims to partially answer the research questions raised in the previous paragraph by evaluating the efficiency of the capacity design of columns for three steel MRFs with viscous dampers. Three alternatives of a prototype building having five, 10 and 20 stories are designed using either steel MRFs or steel MRFs with viscous dampers. The steel MRFs with viscous dampers are designed to have significantly higher performance than that of the steel MRFs. Incremental dynamic analyses (IDA) [20] under 44 ground motions are conducted for all the frames and their collapse resistances and plastic mechanisms (with a focus on column plastic hinges) under different drift levels are evaluated and compared. The results show that tall steel MRFs with viscous dampers are prone to column plastic hinging in comparison to steel MRFs. The steel MRFs with viscous dampers are then iteratively re-designed to achieve a plastic mechanism that is approximately similar to that of the steel MRFs. The performance of the redesigned frames is assessed with IDA and the results are quantitatively and qualitatively evaluated to explore whether there is a need for stricter capacity design rules for columns of high-performance steel MRFs with viscous dampers.

Section snippets

Prototype building

Fig. 1 shows the plan view of a prototype 5-bay by 3-bay steel office building. Three alternatives of this building having five, 10 and 20 stories (as shown in Fig. 2) are considered. The building has two perimeter 3-bay seismic-resistant MRFs in the longitudinal direction and two perimeter 1-bay seismic-resistant braced frames in the transverse plan direction. This study focuses on the design of one of the perimeter MRFs in the longitudinal direction. This perimeter MRF is designed as a steel

Models for nonlinear dynamic analysis and earthquake ground motions

Nonlinear models for the steel MRFs with and without viscous dampers are developed in OpenSees [25]. The columns are modeled as nonlinear force-based beam-column fiber elements with bilinear elastoplastic stress-strain behavior. The assumption of stable hysteresis for the columns is justified by the fact that heavy columns with webs and flanges of low slenderness do not show cyclic deterioration even under large drifts [26]. Beams are modeled as elastic elements with zero length flexural

Collapse fragilities

Incremental dynamic analysis (IDA) [20] is employed for assessing the collapse potential of the steel MRFs with and without viscous dampers. In this method, Sa(T1) is systematically scaled up in increments until the steel MRF becomes globally unstable and drifts increase without bound given a very small increment of Sa(T1). The procedure described in [17] is employed to detect the actual Sa(T1) value leading to collapse of a frame under a specific ground motion. By repeating this procedure for

Assessment of capacity design of columns for steel MRFs with viscous dampers

In this section, the effectiveness of the capacity design of columns for steel MRFs with viscous dampers is assessed and compared to that for steel MRFs without viscous dampers through post-processing of the IDA results. The assessment is based on the number of plastic hinges that develop in the columns. The steel MRFs with viscous dampers experience significantly lower story drifts (and therefore, significantly lower column bending moments) than those of the conventional MRFs for a given

Performance of enhanced steel MRFs with viscous dampers

To explore whether stricter capacity design rules could enhance the seismic performance of steel MRFs with viscous dampers, the interior columns of the 10-story and 20-story steel MRFs with viscous dampers were re-designed. An iterative procedure is followed for that purpose, where the sections of the interior columns experiencing plastic hinges are increased until the median value of the number of column plastic hinges in the re-designed MRF with viscous dampers (referred to as enhanced MRF

Conclusions

Three alternatives of a prototype building having five, 10 and 20 stories were designed according to Eurocode 8 using either steel MRFs or steel MRFs with viscous dampers. The steel MRFs with viscous dampers were designed to have significantly better drift performance than that of the steel MRFs. Incremental dynamic analysis under 44 ground motions were conducted for all the frames and their collapse resistances as well as their plastic mechanisms (with a focus on column plastic hinges) under

References (33)

  • E. Pavlou et al.

    Response of nonstructural components in structures with damping systems

    J Struct Eng

    (2006)
  • Kasai K, Motoyui S, Ozaki H, Ishii M, Ito H, Kajiwara K, Hikino T. Full-Scale Tests of passively-controlled 5-Story...
  • B. Dong et al.

    Seismic response and performance of a steel MRF building with nonlinear viscous dampers under DBE and MCE

    J Struct Eng

    (2016)
  • ASCE 7-10. Minimum design loads for buildings and other structures. American Society of Civil Engineers. Reston,...
  • O.M. Ramirez et al.

    Evaluation of simplified methods of analysis of yielding structures with damping systems

    Earthq Spectra

    (2002)
  • O.M. Ramirez et al.

    Elastic and inelastic seismic response of buildings with damping systems

    Earthq Spectra

    (2002)
  • Cited by (32)

    • Energy-based fragility curves of building structures equipped with viscous dampers

      2022, Structures
      Citation Excerpt :

      For evaluation of the collapse probability of buildings provided with linear and nonlinear FVDs, recent probabilistic analysis has been adopted in many literatures for this issue [24–25,36–45]. These studies are based on some specific procedures, such as the impact of ground motion features on the response of systems with either linear or nonlinear FVDs [24–25,36,38–39], the influence of the FVD nonlinearity [25,40,43,45], the effect of the FVD parameter variability related to the device manufacturing process [40–42], the influence of the principles of the safety factors for FVDs on the consistency of the devices [43], and the effect of FVDs to assess the seismic risk associated with pounding between adjacent structures [37,44]. The FVD with a strong nonlinearity of α leads to increase the probability of collapse of buildings compared with a linear one (α = 1) [24,43–44].

    View all citing articles on Scopus