Volume 41, Issue 5, July 2008, Pages 326-329
NDT & E International

A new technique for measuring the acoustic nonlinearity of materials using Rayleigh waves

https://doi.org/10.1016/j.ndteint.2008.01.007Get rights and content

Abstract

This note presents a procedure to generate nonlinear Rayleigh surface waves without having to drive the transmitting piezoelectric transducer at high voltages; driving at low voltages limits the excitation of the intrinsic nonlinearity of the piezoelectric transducer element, and enables an efficient measurement procedure to isolate inherent material nonlinearity. The capabilities of this proposed technique are demonstrated by measuring the material nonlinearity of aluminum alloy 2024 and 6061 plates with Rayleigh surface waves.

Introduction

The nonlinear acoustic technique has attracted considerable attention in recent years, where experimental results and physical models show that the second-order harmonic amplitude is directly related to fatigue damage [1], [2], [3], [4]. Generally in metals, this fatigue damage first appears in the form of dislocation substructures such as veins and persistent slip bands (PSB), and these accumulate at grain boundaries to produce strain localization. Studies show that these dislocation substructures and resulting micro-plastic deformation do not cause large changes in the macroscopic properties such as elastic modulus, sound speed and attenuation of a material [3], [4], thus the changes in the linear ultrasonic values are not large enough to be accurately measured with conventional linear ultrasonic techniques.

On the other hand, these dislocation substructures will create a slightly nonlinear stress–strain relationship in a localized volume, and their accumulation throughout the continuum will cause a nonlinear distortion in an ultrasonic wave propagating in the material with increasing fatigue damage [5], [6]. This nonlinear distortion will generate higher harmonic components in an initially monochromatic ultrasonic wave signal. For this reason, nonlinear ultrasonic waves can be used to quantify the presence and the density of dislocations in a metallic material, and thus measure fatigue damage in a quantitative fashion. There are a number of advantages of using Rayleigh surface waves in nonlinear acoustics. First, Rayleigh waves do not require access to both sides (one side for generation and the second side for detection) of a component, as is the case for most bulk wave applications; this single-sided technique is particularly promising for field applications, where the availability of two parallel surfaces (each with access available to mount transducers) will be a limiting restriction. Second, most of the energy of Rayleigh waves is concentrated near the stress-free surface, which can lead to stronger nonlinear effects compared to bulk waves, since fatigue damage is typically initiated on the free surface of a component. Finally, Rayleigh waves propagate far distances, making them an ideal means to interrogate large, complex components.

Unfortunately, material nonlinearity—an undamaged material's inherent acoustic nonlinearity plus any nonlinearity from accumulated fatigue damage—is very small, and can easily be overwhelmed by instrumentation nonlinearity. Measuring acoustic nonlinearity can be especially difficult in thin specimens, when there is not enough propagation distance for the second harmonic signal to cumulatively grow above the noise level. Nonlinear ultrasonics requires high-amplitude ultrasonic waves, which usually means driving the transmitting transducer at high voltages. The intrinsic nonlinearity of the transmitting transducer is a major source of this instrumentation nonlinearity; any reduction in transducer nonlinearity will enable a robust measurement procedure capable of isolating material nonlinearity from instrumentation nonlinearity.

This research presents an efficient procedure to generate nonlinear Rayleigh surface waves by directly exciting at an angle from the edge of a specimen. This approach enables driving the transmitting piezoelectric transducer at low voltages (below 60 V peak-to-peak, Vpp) to limit the nonlinear contribution from the transducer. The capability of this system to measure the nonlinear contribution in Rayleigh surface waves is demonstrated by measuring the acoustic nonlinearity of aluminum alloy 2024 and 6061 specimens; these results are in agreement with those available in the literature. The proposed technique is especially well suited to determine the acoustic nonlinearity of thin components, that is, plates and shells, and is much simpler than the traditional longitudinal wave technique.

Section snippets

Acoustic nonlinearity parameter in terms of surface normal displacements of Rayleigh waves

As a first step, the acoustic nonlinearity of a material (β) is related to the fundamental and second-order harmonic displacement amplitudes of a Rayleigh wave measured with a laser interferometer. The relation has been derived in our previous work [2] asβ=8uz(2ω)kl2xuz2(ω)F;F=ks2kR2-kl22(2kR2-ks2)kR,where uz(ω) and uz(2ω) are the fundamental and second-order harmonic amplitudes of a Rayleigh wave displacement; kR, kl and ks are the Rayleigh, longitudinal and shear wave numbers. It is noted

Experimental procedure

A piezoelectric transducer (Panametrics A 405S, 5 MHz, Paintbrush type) is mounted at an angle to the specimen with a fixture and coupled with vacuum grease over a strip of 10 mm long and about a 1 mm wide. The couplant acts as a prism-shaped wedge having a negligibly small volume. The incident angle is adjusted to around 61° with the fixture as shown in Fig. 1. To make sure that Rayleigh waves are being generated at this angle, the wave speed is measured in the pulse-echo mode, and a wave speed

Results and summary

Consider two plate specimens made of aluminum alloy, Al-2024-T3 and Al-6061-T6, with thicknesses of 8.06 and 9.53 mm, respectively. Their material properties are shown in Table 1. Measurements are made at seven different propagation distances varying from about 15 to 27 cm along the centerline from the transducer, and each set of measurements is repeated twice. The near-field/far-field distance for the present setup is about 15 cm, and thus, all measurements are taken in the far-field. Note that

Acknowledgments

This work was partially supported by the National Natural Science Foundation of China under Grant no. 10228204 and the National Science Foundation under CMMI-0653883.

References (10)

  • P.B. Nagy

    Fatigue damage assessment by nonlinear ultrasonic material characterization

    Ultrasonics

    (1998)
  • J. Herrmann et al.

    Assessment of material damage in a nickel-base superalloy using nonlinear Rayleigh surface waves

    J Appl Phys

    (2006)
  • J. Frouin et al.

    Ultrasonic linear nonlinear behavior of fatigued Ti-6Al-4V

    J Mater Res

    (1999)
  • J.-Y. Kim et al.

    Experimental characterization of fatigue damage in a nickel-base superalloy using nonlinear ultrasonic waves

    J Acoust Soc Am

    (2006)
  • J.H. Cantrell

    Substructural organization, dislocation plasticity and harmonic generation in cyclically stressed wavy slip metals

    Proc R Soc London A

    (2004)
There are more references available in the full text version of this article.