Elsevier

Journal of Vascular Surgery

Volume 72, Issue 6, December 2020, Pages 1897-1905.e2
Journal of Vascular Surgery

Clinical research study
Thoracoabdominal and complex aortic aneurysms
A novel physician-assembled endograft for the repair of pararenal, paravisceral, Crawford type IV thoracoabdominal aortic aneurysms, and aneurysms requiring treatment after prior repair

https://doi.org/10.1016/j.jvs.2020.03.045Get rights and content
Under a Creative Commons license
open access

Abstract

Objective

In the present study, we reviewed the 30-day and 1-year clinical results of the use of the investigational unitary manifold (UM) stent graft system (Sanford Health, Sioux Falls SDak) for the repair of Crawford type IV, pararenal, paravisceral, juxtarenal, and short-neck infrarenal aneurysms (<10 mm).

Methods

The present study was a single-center, multiarm, prospective review of the first 44 patients who had undergone repair of Crawford type IV, pararenal, juxtarenal, and short-neck infrarenal aneurysms (<10 mm) using the physician-modified UM under a physician-sponsored investigational device exemption. The primary end point was freedom from major adverse events at 30 days, including all-cause mortality, myocardial infarction, stroke, paraplegia, bowel ischemia, respiratory failure, and renal failure.

Results

Technical success was achieved in all 44 patients (100%), with a large number of these patients having undergone previous aortic repair (20 of 44; 45.5%). All the intended 170 visceral vessels (100%) had been successfully cannulated and stent grafted. No episodes of paraplegia or in-hospital deaths were recorded. One patient had died of aneurysm-related ischemic stroke (2.3%). The rate of transient nonclinically significant spinal cord ischemia was 4.5%. At the last follow-up, one reintervention had been required owing to branch patency from a thrombotic event. Of the 170 bridging stent grafts, 169 have remained patent through a mean follow-up of 8.8 months (range, 0-36 months). No type I or III endoleaks, migration, or component separation in the investigational device has occurred.

Conclusions

The early and midterm results with the use of the UM suggest it could be a viable option for the repair of Crawford type IV, pararenal, paravisceral, juxtarenal, and short-neck infrarenal aneurysms (<10 mm) without exposing patients to the increased risk of permanent spinal cord ischemia, renal failure, visceral vessel ischemia, or aneurysm-related mortality that results from open thoracoabdominal aortic aneurysm repair. The high technical success rate, in native and previous repairs, supports the utility of this device as a bail-out technique for failed endovascular aneurysm repair or proximal extension of disease after previous aortic repair. However, experience is limited, and this approach requires further study before widespread adoption.

Keywords

Branched
Complex aneurysm repair
Endovascular aortic repair
Thoracoabdominal aneurysm

Cited by (0)

Clinical Trail registration: NCT02294435.

This study was funded by Sanford Health, United States.

Author conflict of interest: A.V., K.P., T.R., and P.K. have received payments related to license and royalty interest with Medtronic.

Additional material for this article may be found online at www.jvascsurg.org.

The editors and reviewers of this article have no relevant financial relationships to disclose per the JVS policy that requires reviewers to decline review of any manuscript for which they may have a conflict of interest.