ScienceDirect® Home Skip Main Navigation Links
You have guest access to ScienceDirect. Find out more.
 
Home
Browse
My Settings
Alerts
Help
 Quick Search
 Search tips (Opens new window)
    Clear all fields    
advertisementadvertisement
Journal of Chromatography B
Volume 854, Issues 1-2, 1 July 2007, Pages 291-298
 
Font Size: Decrease Font Size  Increase Font Size
 Abstract - selected
Article
Purchase PDF (524 K)

  E-mail Article   
  Add to my Quick Links   
Bookmark and share in 2collab (opens in new window)
Request permission to reuse this article
  Cited By in Scopus (0)
 
 
 
Related Articles in ScienceDirect
View More Related Articles
 
Special issue
View Record in Scopus
 
doi:10.1016/j.jchromb.2007.04.043    How to Cite or Link Using DOI (Opens New Window)
Copyright © 2007 Elsevier B.V. All rights reserved.

Improved and simplified liquid chromatography/electrospray ionization mass spectrometry method for the analysis of underivatized glucosamine in human plasma

Sheng Zhonga, b, Dafang Zhonga and Xiaoyan Chena, Corresponding Author Contact Information, E-mail The Corresponding Author

aCenter for Drug Metabolism and Pharmacokinetics Research, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, 646 Songtao Road, Shanghai 201203, PR China bShenyang Pharmaceutical University, 103 Wenhua Road, Shenyang 110016, PR China

Received 15 January 2007; 
accepted 24 April 2007. 
Available online 10 May 2007.

Purchase the full-text article



References and further reading may be available for this article. To view references and further reading you must purchase this article.

Abstract

Glucosamine is an amino monosaccharide reagent. It is difficult to assay using typical reversed-phase column due to the early elution, by optimizing the chromatographic conditions, especially the analytical column and the mobile phase composition, an improved analytical method was developed and validated, which offers rapid, sensitive and specific determination of glucosamine in human plasma. Following protein precipitation, the analyte and internal standard (valibose) were separated using an isocratic mobile phase on an Inertsil CN-3 column and detected by mass spectrometry in the multiple reaction monitoring mode using the respective precursor to product ion combinations of m/z 180/72 for glucosamine and m/z 252/198 for valibose. The chromatographic time was just 4.2 min for each sample, which made it possible to analyze more than 120 human plasma samples per day. The method exhibited a linear dynamic range of 4.00–4000 ng/mL for glucosamine in human plasma. The lower limit of quantification (LLOQ) was 4.00 ng/mL with a relative standard deviation of less than 10.9%. Acceptable precision and accuracy were obtained for the plasma concentrations over the standard curve range. By monitoring the two different MRM transitions, it was proved that no endogenous glucosamine was found in human plasma. The validated method has been successfully used to analyze human plasma samples for application in a bioequivalence study.

Keywords: Glucosamine; Chromatography optimization; LC/MS/MS; Plasma concentration

Article Outline

1. Introduction
2. Experimental
2.1. Chemicals
2.2. LC/MS/MS instruments and conditions
2.3. Preparation of calibration standards and quality control samples
2.4. Sample preparation
2.5. Bioanalytical method validation
2.6. Application to bioequivalence study
3. Results and discussion
3.1. Mass spectrometry conditions
3.2. Chromatographic conditions
3.3. Internal standard selection
3.4. Method validation
3.4.1. Selectivity and matrix effect
3.4.2. Linearity of calibration curves and lower limit of quantification
3.4.3. Precision and accuracy
3.4.4. Recovery and stability
3.5. Application
4. Conclusion
References






 
Home
Browse
My Settings
Alerts
Help
Elsevier.com (Opens new window)
About ScienceDirect  |  Contact Us  |  Information for Advertisers  |  Terms & Conditions  |  Privacy Policy
Copyright © 2008 Elsevier B.V. All rights reserved. ScienceDirect® is a registered trademark of Elsevier B.V.