The flow properties and presence of crystals in drug-polymer mixtures: Rheological investigation combined with light microscopy

https://doi.org/10.1016/j.ijpharm.2017.06.012Get rights and content

Abstract

The presence of solid matter in polymer melts affects the rheological properties of a drug-polymer mixture, and thus the processability of these mixtures in melt-based processes. The particle morphological changes related to dissolution and crystal growth in the mixtures of paracetamol and ibuprofen with polyethylene oxide and methacrylate copolymer (Eudragit® E PO) were observed by polarized microscopy simultaneously while measuring their rheological properties within temperature ranges relevant for melt processes, such as hot melt extrusion and fused deposition modeling 3D printing. The dissolution of solid crystalline matter into the molten polymer and its effects on the rheological parameters showed that the plasticization effect of the drug was highly dependent on the temperature range, and at a temperature high enough, plasticization induced by the small-molecule drugs could enhance the flowability even at very high drug loads. Therefore, even supersaturated mixtures can be plasticized efficiently, enabling their melt processing, such as hot melt extrusion or 3D printing. The combination of rheometry and polarized light microscopy proved to be very useful for studying the link between morphological changes in the drug-polymer and the flow behavior of the drug-polymer mixtures at different temperature ranges and deformation modes.

Introduction

Continuous manufacturing using hot melt extrusion (HME), and the potential downstream manufacturing steps, such as pelletization, calendaring into films, or fused deposition modeling (FDM) 3D printing, enables manufacturing of personalized medicine in innovative ways (Bialleck and Rein, 2011, Breitenbach, 2002, Norman et al., 2017, Water et al., 2015, Wening and Breitkreutz, 2011). HME involves several critical steps: first, mixing of drug in polymeric excipient at elevated temperature and shear stress by screw rotation; second, the mixture is extruded through the die; third, the molten mixture is solidified, and finally, further processed in subsequent steps (Breitenbach, 2002). For FDM, the drug-containing feed material (i.e., the filament) can be prepared by HME (Melocchi et al., 2016, Water et al., 2015). During melt processing, the drug-polymer mixture is subjected to heat and shear stresses, which can result in varying solid form composition ranging from molecularly dispersed solid solution to a solid drug-polymer suspension (Forster et al., 2001). Molecularly dispersed solid solutions produced employing HME process can enhance the dissolution characteristics of poorly soluble drugs, as shown recently, for example, by Kalivoda et al. (2012) and Sathigari et al. (2012). However, also extruded solid suspensions, where both the drug and the carrier are in crystalline form (Thommes et al., 2011), as well as co-crystallized, extruded mixtures of two compounds (Boksa et al., 2014) have been shown to have a superior dissolution characteristics when compared to the pure drug or physical mixture of co-crystal components. Above the thermodynamic drug-polymer solubility limit the drug can be present as molecularly dispersed continuous phase, as well as in phase separated amorphous or crystalline domains. HME process may be able to produce a homogeneously mixed supersaturated solid solution, where the drug is kinetically stabilized, since this is greatly enhanced by the high temperature and shear involved in the process (Qian et al., 2010). However, recrystallization of the drug in such mixtures may occur during the storage (Qi et al., 2010, Qi et al., 2008). Working Diagrams − albeit not straightforward to construct − based on the experimentally and theoretically obtained miscibility and solubility studies, may assist in evaluating the long-term stability of the extruded drug-polymer mixtures, as a function of the drug load, temperature, and the Tg of the polymer (Knopp et al., 2015, Marsac et al., 2008, Qian et al., 2010).

For orally administered high-dose drugs the relative amount of excipients must be kept as low as possible, in order to keep the dosage form size at an acceptable level. Melt processing of such highly concentrated, high-viscous dispersions poses various challenges: The interactions between closely packed solid particles in concentrated suspensions can cause formation of a reversible structural network, which needs energy to be broken down before any deformation can occur upon applied stress (Tadros, 1990). Fully insoluble or supersaturated drug-polymer mixtures may exhibit apparent yield stress, whereby their viscosity at low shear rates is very high, approaching solid-like behavior (Aho et al., 2016). On the other hand, small molecule drugs soluble in the molten polymer act like plasticizers, decreasing the viscosity and the glass transition temperature (De Brabander et al., 2002). When the temperature of the melt mixture is sufficiently close to the melting temperature of the drug, plasticization effect can also be seen in a supersaturated drug-polymer mixture, showing flow behavior similar to two-phase liquid-liquid systems (Aho et al., 2016). In the case of partially miscible, supersaturated drug-polymer mixtures, the rheological behavior is dictated by the viscosity of the plasticized phase consisting of the polymer and the drug dissolved in it, and by the immiscible drug, which could be present either as suspended, undissolved particles or amorphous phase-separated domains – or potentially, as a combination of these.

When plasticization in drug-polymer mixtures is evaluated solely based on the decrease in the Tg or Tm, using thermal methods such as differential scanning calorimetry (DSC), its significance to the flowability in HME cannot be fully assessed. Therefore, rheological characterization is necessary for evaluating effects of the dissolved or suspended drug on the viscosity and viscoelasticity of the melt. Chokshi et al. (2005) suggested that indomethacin − PVP VA binary mixtures were fully miscible evaluated by thermal analysis, where a decrease of Tg was observed as a function of increasing drug load. This was supported by rheological measurements, where the drug-polymer mixtures had a lower zero-shear viscosity than the polymer alone, even when the drug load was as high as 70%. However, for indomethacin- Eudragit E PO, DSC showed an antiplasticization effect, Tg of the drug-polymer mixtures being above the Tg of the individual components. Despite that, the rheological measurements at 140 °C indicated an enhanced plasticization effect with increasing drug load. In another study Liu et al. (2012) found a strong plasticization effect in indomethacin-Eudragit E PO in oscillatory shear tests performed at 145 °C even at 80% drug load, while a similar Tg trend as in (Chokshi et al., 2005) was observed by DSC for the physical mixtures beyond 30% indomethacin content. In our previous study (Aho et al., 2016), a viscosity decrease was observed for ibuprofen-polyethyleneoxide (IBU-PEO) mixtures with 70% IBU content at 70 °C, while the thermal analysis of the mixture showed two separate Tm peaks, indicating supersaturation. On the other hand, at 60 °C the mixture had flow behavior typical of concentrated suspensions with a viscosity above that of pure PEO. This, as well as the above discussed studies show that the temperature clearly plays a significant role: At a lower temperature the drug can be present as suspended crystals, while upon increasing the temperature to the vicinity of the Tm of the drug (for IBU Tm = 76 °C) it can form an amorphous phase and thus decrease the viscosity of the mixture, even without being fully miscible with the polymer, as indicated by DSC.

The preceding discussion shows that the plasticization evaluation using only thermal analysis does not give a full picture of the plasticization in terms of processability. Capillary rheometry enables studying the plasticization effect in similar thermomechanical conditions and shear rates as those occurring in HME, as recently shown by Jones et al. (2015) in their study on the miscibility and processability of quinine base and quinine hydrochloride in Eudragit E100, in hydroxypropylcellulose, and in their blends. However, in order to study the viscoelasticity and molecular level interactions, a rotational rheometer in oscillation mode is the proper choice of test equipment.

The combined use of rheometry and polarized microscopy enables simultaneous observation of the changes in the particle morphology and the flow characteristics of the mixture, allowing for the assessment of the effects of temperature, time, and shear. The usefulness of this technique has been earlier demonstrated in investigation of ibuprofen and theophylline and their extruded mixtures with Soluplus® (Plog and Soergel, 2013). In this study the mixtures of ibuprofen and paracetamol with PEO from our earlier study (Aho et al., 2016) were investigated, with the aim of gaining a deeper understanding on the relationship between particle morphology and rheological properties. Additionally, an amorphous polymer Eudragit® E PO was used in order to enable microscopy observation of the changes in the drug morphology without the effect of a partially crystalline polymer.

Section snippets

Materials

Model drugs, ibuprofen (IBU, Tm = 76 °C,) and paracetamol (PRC, Tm = 169 °C), both purchased from Fagron Nordic A/S (Copenhagen, Denmark), were studied as physical mixtures with either polyethylene oxide (PEO, Mv = 100,000 g/mol, Tg = –67 °C, Tm = 65 °C, Sigma-Aldrich Denmark A/S, Copenhagen, Denmark), or with an amorphous methacrylate copolymer, Eudragit® E PO (EDG, Mw = 47,000 g/ mol, Tg = 45 °C, Evonik Industries, Darmstadt, Germany). The drug-polymer ratios were chosen based on the previous results (Aho et al., 2016

Results

Results of the rheological measurements through steps I–V and still snapshots from the microscopy recordings in steps I, II, and V are shown in the following section. Videos were recorded throughout the entire measurement (steps I–V), starting the recording at the same time with the experiment (small variation in the video lengths exist). The videos for each measurement are available as Supplementary material. In order to reduce the file size and the viewing time, the video speed was doubled;

Discussion

The changes in the particle morphology and moduli over time showed that the drug dissolution in the polymers was slow, which can be partially attributed to the high viscosity of the solvent (in this case the polymer melt), as can be expected from the diffusion coefficient in the well-known Noyes-Whitney equation. The potential transient behavior should be kept in mind when carrying out rheological experiments for drug-polymer mixtures as the effect of time might be obscured by other variables

Conclusions

We have demonstrated the use of a combined rheometer and optical microscope setup (Rheoscope® technology) for observing the morphological changes in drug-polymer mixtures under high temperatures relevant for processes such as hot melt extrusion or FDM 3D printing. The experiments visually showed the dissolution of crystals as well as crystal growth in series of time and temperature sweeps, with related changes in the rheological data (shear viscosity or dynamic moduli). In highly concentrated,

Acknowledgements

The authors wish to thank Magnus Edinger for providing the XRPD diffractograms of extruded ibuprofen-PEO mixtures and Johan P. Boetker for assisting in video editing. J. Aho, L. Arnfast, and J. Rantanen acknowledge funding from the Danish Council for Independent Research (DFF), Technology and Production Sciences (FTP), project 12-126515/0602-02670B.

References (39)

Cited by (16)

  • Polymers in pharmaceutical additive manufacturing: A balancing act between printability and product performance

    2021, Advanced Drug Delivery Reviews
    Citation Excerpt :

    The temperature required in FDM printing is often higher than in HME because of the lower shear in the printer extruder combined with low residence time in the nozzle compared to HME [94]. To assess rheological properties of melts temperature-controlled rheometers are used in various configurations, including parallel-plate and cone-plate geometries [95,171,211]. Typical parameters assessed are complex viscosity and storage and loss moduli.

  • Solubilizing temperature of crystalline drug in polymer carrier: A rheological investigation on a posaconazole-copovidone system with low drug load

    2021, European Journal of Pharmaceutics and Biopharmaceutics
    Citation Excerpt :

    Due to the high viscosity of the polymer, the establishment of complete solubilization of the crystalline API into the polymeric melt is kinetically slow, hence tracking the formation of amorphous solid dispersion in the extruder and precisely measuring the solubility of crystalline API in the polymeric carrier are challenging and of interest[6,7]. Furthermore, the difficulty is expected to be greater in a more viscous polymer-rich system[8,9]. On the other hand, the solubility of the crystalline API in the polymer is also related to the physical stability of the obtained amorphous solid dispersion[10–12].

  • Quality considerations on the pharmaceutical applications of fused deposition modeling 3D printing

    2021, International Journal of Pharmaceutics
    Citation Excerpt :

    Chemical analyses and solid-state characterization of formulation components were also performed by other analytical techniques (e.g., X-rays, infrared spectroscopy and high performance liquid chromatography) to rule out any modification associated with hot-processing. Rheological characterization was performed by standard methods, such as melt-flow index determination, to get a first indication of material printability, and rotational or capillary rheometry when more accurate data were needed, also in view of the modeling of the FDM process (Aho et al., 2015, 2017, Baldi et al., 2014, 2017; Casati et al., 2018; Matijašić et al., 2019b). A strict control over the filament diameter and shape is needed, as dimensional fluctuations cause changes in the flow of material through the nozzle and subsequent potential nonconformities in printed part dimensions and drug content.

  • Exploring tablet design options for tailoring drug release and dose via fused deposition modeling (FDM) 3D printing

    2020, International Journal of Pharmaceutics
    Citation Excerpt :

    On one hand, improved miscibility and lower viscosity at higher processing temperature reduces the load on the equipment and could help mixing. On the other hand, higher temperature could lead to polymer and drug degradation and it could adversely affects filament quality necessary for FDM 3D printing (Aho et al., 2017, Censi et al., 2018, Govender et al., 2020, Kempin et al., 2017, Solanki et al., 2018a, Yang et al., 2016). Moreover, the resulting ASDs have the inherent stability problems due to the tendency for the amorphous forms to recrystallize in time that may influence the performance of the products such as drug dissolution behavior.

  • Holistic QbD approach for hot-melt extrusion process design space evaluation: Linking materials science, experimentation and process modeling

    2019, European Journal of Pharmaceutics and Biopharmaceutics
    Citation Excerpt :

    Specifically, some of the most important material properties are the initial API particle size, matrix polymer and API glass transition temperatures (Tg), the API melting and solubility temperatures (Tm and Ts), the API and matrix degradation temperatures (Td), and the matrix melt viscosity as a function of temperature and shear rate. In addition to being a function of temperature and shear rate, the matrix melt viscosity can also be a function of additional components incorporated within it, such as moisture content, undissolved and dissolved API, surfactant and plasticizer, depending on relative concentrations [9–28]. Characterization of the matrix Tg and melt viscosity have been investigated to identify the minimum processing temperature and extruder torque limitation [29–31,9,32,10,33,34].

View all citing articles on Scopus