Several disinfection processes of ultraviolet (UV), chlorine or UV followed by chlorine were investigated in municipal wastewater according to the inactivation of Escherichia coli, Shigella dysenteriae and toxicity formation. The UV inactivation of the tested pathogenic bacteria was not affected by the quality of water. It was found that the inactivated bacteria were obviously reactivated after one day in dark. Fluorescent light irradiation increased the bacteria repair. The increase of UV dosage could cause more damage to bacteria to inhibit bacteria self-repair. No photoreactivation was detected when the UV dose was up to 80 mJ/cm2 for E. coli DH5a, and 23 mJ/cm2 for S. dysenteriae. Nevertheless, sequential use of 8 mJ/cm2 of UV and low concentration of chlorine (1.5 mg/L) could effectively inhibit the photoreactivation and inactivate E. coli below the detection limits within seven days. Compared to chlorination alone, the sequential disinfection decreased the genotoxicity of treated wastewater, especially for the sample with high NH3-N concentration.

References (21)

There are more references available in the full text version of this article.

Cited by (32)

  • A dose optimization method of disinfection units and synergistic effects of combined disinfection in pilot tests

    2022, Water Research
    Citation Excerpt :

    This results in higher inactivation efficiency of Bacillus subtilis spores and lower formation of trihalomethane and haloacetic acids (Chin and Berube, 2005; Jung et al., 2008). Sequential UV-chlorine (UV irradiation first, then chlorination) and UV/chlorine combined processes can effectively improve stability of water quality, decrease genotoxicity, and inhibit the formation of some DBPs by reducing disinfectant doses or generating advanced oxidation (Jia et al., 2019; Li et al., 2018a, 2016; Wang et al., 2014, 2011, 2012). Furthermore, ozone or UV pretreatment may remove some chlorine-resistant bacteria (Ding et al., 2019; Shekhawat et al., 2021).

  • Radical-promoted formation of dibenzofuran during combined UV-chlorine treatment on mono-substituted diphenyl ether

    2021, Chemical Engineering Journal
    Citation Excerpt :

    Among them, combined UV-chlorine treatment has attracted wide attention. It shows obvious advantages in killing various microorganisms, and can reduce disinfectant demand and ensure lasting disinfection ability [3–5]. Moreover, combined UV-chlorine treatment is also a promising advanced oxidation process.

View all citing articles on Scopus