Seminar on clinical application of techniques to measure blood flow in man. Part II
Measurement of blood flow by thermodilution

https://doi.org/10.1016/0002-9149(72)90635-2Get rights and content

Abstract

In thermodilution a known change in heat content of the blood is induced at one point of the circulation and the resultant change in temperature detected at a point downstream. When cardiac output is measured, a bolus of cool liquid is injected into the upper right atrium and the temperature change detected in the pulmonary artery. When flow in single blood vessels is measured, the distance between the site of injection and the site of detection is small; therefore, mixing must be attained by the kinetic energy of the injectate. The continuous constant rate injection technique is most suitable for measurement of venous flow. Since the blood flow in arteries can be markedly and unpredictably altered by the injection or the injectate, this technique is not suitable to measure flow in arteries. Measurement of venous flow by the bolus injection technique is tedious and time-consuming because of the complex formula. Minimal recirculation, simple and accurate calibration, intravascular detection of temperature and simple equipment are the advantages of the thermodilution technique.

References (32)

  • HH Khalil

    Determination of cardiac output in man by a new method based on thermodilution

    Lancet

    (1963)
  • W Ganz et al.

    A new technique for measurement of cardiac output by thermodilution in man

    Amer J Cardiol

    (1971)
  • G Fegler

    Measurement of cardiac output in anesthetized animals by a thermodilution method

    Quart J Exp Physiol

    (1954)
  • HH Khalil

    Determination of cardiac output in man by a new method based on thermo-dilution (abstr)

  • S Afonso

    A thermodilution flowmeter

    J Appl Physiol

    (1966)
  • A Fronek et al.

    Measurement of flow in single blood vessels including cardiac output by thermodilution

    Circ Res

    (1960)
  • KF Hosie

    Thermal dilution technics

    Circ Res

    (1962)
  • AVN Goodyer et al.

    Thermal dilution curves in the intact animal

    Circ Res

    (1959)
  • E Rappaport et al.

    The measurement of cardiac output by thermodilution method

    Clin Res

    (1958)
  • K Pavek et al.

    Measurement of cardiac output by thermodilution with constant rate injection of indicator

    Circ Res

    (1964)
  • HH Khalil et al.

    Measurement of cardiac output by thermal-dilution and direct Fick methods in dogs

    J Appl Physiol

    (1966)
  • MA Branthwaite et al.

    Measurement of cardiac output by thermal dilution in man

    J Appl Physiol

    (1968)
  • HA Solomon et al.

    Cardiac output determination: superiority of thermal dilution

  • R Single et al.

    Simultaneous determinations of cardiac output by thermal dilution, fiberoptic and dye-dilution methods

    Amer J Cardiol

    (1970)
  • S Afonso et al.

    Temperature variations in the venous system of dogs

    Amer J Physiol

    (1962)
  • S Afonso et al.

    Intravascular and intracardiac blood temperatures in man

    J Appl Physiol

    (1962)
  • Cited by (0)

    This work was supported in part by National Institutes of Health Grant HE-12337, Los Angeles County Heart Association Grant 412, United Hostesses, Eagles Fund, National Institutes of Health Contract PH-43-681333 (Myocardial Infarction Research Unit), and U. S. Public Health Service Grant 5 SO1 RR05468.

    View full text