Acquired cardiovascular disease
Transapical transcatheter aortic valve implantation: Follow-up to 3 years

Read at the Thirty-fifth Annual Meeting of The Western Thoracic Surgical Association, Banff, Alberta, Canada, June 24–27, 2009.
https://doi.org/10.1016/j.jtcvs.2009.10.056Get rights and content
Under an Elsevier user license
open archive

Background

We performed the first human case of successful transapical transcatheter aortic valve implantation on a beating heart in October 2005, and therefore we have the longest follow-up on transapical aortic valve implantation in humans. We now report clinical and echocardiographic outcomes of transapical aortic valve implantation in 71 patients.

Methods

Between October 2005 and February 2009, 71 patients (44 female) underwent transcatheter transapical aortic valve implantation with either 23- or 26-mm Edwards Lifesciences transcatheter bioprostheses. All patients with symptomatic aortic stenosis were declined for conventional aortic valve replacement owing to unacceptable operative risks and were not candidates for transfemoral aortic valve implantation because of poor arterial access. Clinical and echocardiographic follow-ups were performed before discharge, at 1 and 6 months, and then yearly. The mean follow-up was 12.9 ± 11.5 months with a total of 917.3 months of follow-up.

Results

Mean age was 80.0 ± 8.1 years and predicted operative mortality was 34.5% ± 20.4% by logistic EuroSCORE and 12.1% ± 7.7% by The Society of Thoracic Surgeons Risk Calculator. Valves were successfully implanted in all patients. Twelve patients died within 30 days (30-day mortality: 16.9% in all patients, 33% in the first 15 patients, and 12.5% in the remainder), and 10 patients died subsequently. Overall survival at 24 and 36 months was 66.3% ± 6.4% and 58.0% ± 9.5%, respectively. Among 59 patients who survived at least 30 days, 24- and 36-month survivals were 79.8% ± 6.4% and 69.8% ± 10.9%, respectively. Late valve-related complications were rare. New York Heart Association functional class improved significantly from preoperative 3.3 ± 0.8 to 1.8 ± 0.8 at 24 months. The aortic valve area and mean gradient remained stable at 24 months (1.6 ± 0.3 cm2 and 10.3 ± 5.9 mm Hg, respectively).

Conclusion

Our outcome suggests that transapical transcatheter aortic valve implantation provides sustained clinical and hemodynamic benefits for up to 36 months in selected high-risk patients with symptomatic severe aortic stenosis.

CTSNet classification

28
35

Abbreviations and Acronyms

AVI
aortic valve implantation
AVR
aortic valve replacement
CPB
cardiopulmonary bypass
NYHA
New York Heart Association
STS
The Society of Thoracic Surgeons

Cited by (0)

Disclosures: Drs Ye, Webb, Munt, and Cheung are consultants to Edwards Lifesciences Inc, Irvine, California. Dr Webb has also received financial support for research from Edwards Lifesciences Inc. Dr Moss has received honoraria from Edwards. The remaining authors have no financial relationship to disclose.