Elsevier

Ultrasound in Medicine & Biology

Volume 11, Issue 1, January–February 1985, Pages 13-26
Ultrasound in Medicine & Biology

Original contribution
Hemodynamics of the normal human carotid bifurcation: In vitro and in vivo studies

https://doi.org/10.1016/0301-5629(85)90003-1Get rights and content

Abstract

The spatial and temporal characteristics of blood flow in the normal adult human carotid bifurcation are investigated by two different methods: in vitro pulsatile flow model experiments using laser Doppler anemometry and in vivo studies employing pulsed Doppler velocity measurements obtained with an ultrasound duplex scanner. Glass and Plexiglas models based upon arteriographic measurements were evaluated with laser Doppler anemometer methods for pulsatile flow. A similarity approach permits the model study to be geometrically and hydrodynamically accurate with respect to the human carotid bifurcation. These parallel but separate approaches were originally performed by the principal authors without knowledge of each others' work.

Normal flow patterns in the proximal internal carotid artery are demonstrated to include: unidirectional, helical, transient reversal, and low velocity regions of flows. The characterization of these complex temporal and spatially variant flow fields required the high sample volume resolution afforded by the model study. Pulsed Doppler ultrasound and a novel method of positioning the sample volume permitted a qualitative description of the complex flow velocity fields in the normal human bifurcation. Results of the two methods are compared and a striking similarity between the two methods is observed for the primary and secondary flow features.

The problem of associating blood flow velocity disturbances with the presence of intralumenal disease is addressed in the discussion. It is suggested that the flow disturbances associated with the normal carotid bifurcation are different from those associated with intraluminal disease and further, that the secondary flow structures can be usefully employed to establish normalcy.

References (26)

  • M.A. Brandestini

    Topoflow-a digital full range Doppler velocity meter

    IEEE Trans. Sonics Ultrasonics

    (1978)
  • P.J. Breslau et al.

    Ultrasonic duplex scanning with spectral analysis in extracranial carotid artery disease

    Vascular Diag. and Therapy

    (1982)
  • R.E. Daigle

    Aortic flow sensing using an ultrasonic esophageal probe

  • Cited by (160)

    • Computational analysis of the coronary artery hemodynamics with different anatomical variations

      2020, Informatics in Medicine Unlocked
      Citation Excerpt :

      Low values of TAWSS promote atherogenic endothelial phenotype, where high values of TAWSS can be thrombogenic [42]. The OSI is a dimensionless hemodynamic parameter commonly used to identify the atheroprone regions of the artery [37]. RRT is a descriptor used to pinpoint the region of oscillatory and low WSS [38].

    • Artificial stenoses for computational hemodynamics

      2018, Applied Mathematical Modelling
      Citation Excerpt :

      Malek et al. [15] associated specific regions of the arterial tree prone to atherosclerosis with low wall shear stress magnitude (< 0.4 Pa) and concluded that the typical value of WSS in blood vessels varies between 1.5 and 2.0 Pa. For both normal and stenosed vessels, analytical, numerical, and experimental studies are recognised to help in the prediction, prevention and better understanding of atherosclerosis disease [12,16–19]. There are several studies based on idealized geometries using stenoses with idealized shapes (e.g. half spheres, ellipsoids, toroids) [17,20–22].

    View all citing articles on Scopus

    Address for reprints: D. J. Phillips, Department of Surgery, RF-25. University of Washington, Seattle, WA 98195. U.S.A.

    View full text