Effects of temporary arterial occlusion on somatosensory evoked responses in aneurysm surgery☆
References (15)
- et al.
Relationship between the cortical evoked potential and local cortical blood flow following acute middle cerebral artery occlusion in the baboon
Exp Neurol
(1974) - et al.
Cortical evoked potential and extracellular K+ and H+ at critical level of brain ischaemia
Stroke
(1977) - et al.
Comparison of the effects of ischemia on early components of somatosensory evoked potential in brainstem, thalamus, and cerebral cortex
J Cereb Blood Flow Metab
(1984) - et al.
Recovery of the cortical evoked response following temporary middle cerebral artery occlusion in baboons: relation to local blood flow and PO2
Stroke
(1976) - et al.
Central conduction time in primate brain ischaemia: a study in baboons
Stroke
(1980) - et al.
Cortical neural function during ischaemia: effects of occlusion of one cerebral artery on single-unit activity in cats
Arch Neurol
(1976) - et al.
Surgical risk as related to time of intervention in the repair of intracranial aneurysms
J Neurosurg
(1968)
Cited by (79)
Intraoperative neurophysiologic monitoring in brain aneurysm surgery
2018, Intracranial AneurysmsPerioperative stroke after cerebral aneurysm clipping: Risk factors and postoperative impact
2017, Journal of Clinical NeuroscienceCitation Excerpt :The H/H scale is used to estimate the severity of aneurysmal subarachnoid hemorrhage based on patient clinical condition [29]. This study suggests that patients presenting with H/H grade 5 aneurysm ruptures can be further stratified for increased risk of perioperative stroke, which is consistent with a higher frequency of vasospasm in patients with high-grade H/H and Fisher (CT-based evaluation of subarachnoid blood load) scores [30–32]. However, this finding is limited by the small number of patients (n = 5) presenting with H/H grade 5 aSAH.
Ischemia changes and tolerance ratio of evoked potential monitoring in intracranial aneurysm surgery
2013, Clinical Neurology and NeurosurgeryCitation Excerpt :Because there is a close relationship between reduction in SEP amplitude and reduced cerebral blood flow, SEP monitoring is widely used to detect cerebral ischemia [6,7]. Intraoperative SEP monitoring is considered particularly useful during cases involving temporary occlusion and can predict the cortical ischemia [8]. Due to their small size and other complicating factors, there is a significant risk of accidentally clamping perforating vessels in intracranial aneurysm surgery; promptly detecting these errors and correcting them is key to minimizing postoperative neurological deficits.
Monitoring techniques for prevention of procedure-related ischemic damage in aneurysm surgery
2012, World NeurosurgeryANESTHETIC MANAGEMENT OF CEREBRAL ANEURYSM SURGERY
2010, Cottrell and Young's Neuroanesthesia: Fifth EditionComplications in Interventional Neuroradiology of the Head and Neck
2009, Complications in Head and Neck Surgery with CD Image Bank
- ☆
This work was supported by grants from the Wellcome Foundation and the Medical Research Council.