Skip to main content

Advertisement

Log in

Biopsy at flexible cystoscopy: is it worthwhile?

  • Original Article
  • Published:
Irish Journal of Medical Science (1971 -) Aims and scope Submit manuscript

Abstract

Introduction

Flexible cystoscopy is the gold standard for diagnosis and surveillance of bladder carcinoma. Most flexible cystoscopes feature a working channel allowing for bladder biopsy and diathermy if a suspicious lesion is observed. However, the working channel permits only small instruments which limit the volume of material retrieved for histological analysis. There are no published standards for quality control of biopsy specimens taken at flexible cystoscopy. We reviewed the diagnostic yield of biopsies taken at flexible cystoscopy at our institution.

Methods

Theatre log books were retrospectively examined to identify cases of flexible cystoscopy where bladder biopsy was performed. Histopathology reports were reviewed. All biopsies were taken using single-use biopsy forceps, diameter 1.8 mm, open cup width 4.5 mm.

Results

From January 2014 to December 2017, a total of 143 biopsies were performed. All biopsies were taken for suspicious lesions where the differential diagnosis included malignancy. Of the 143 samples taken, 27 biopsies showed evidence of malignancy, and 9 cases were high-grade urothelial cancer. A total of 16 samples were inadequate for any histological diagnosis. All remaining samples excluded malignancy within the sample provided. A histopathological diagnosis was provided for almost 89% of cases.

Conclusion

Approximately 18% of biopsies detected malignancy. While only small volumes of tissue are collected at flexible cystoscopy, these can help to distinguish malignancy from benign pathology. Our institution reports a non-diagnostic rate of approximately 11%, and in these cases, when there is still a suspicion of malignancy, a rigid cystoscopy and biopsy should be performed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. Pillai PL, Sooriakumaran P (2009) Flexible cystoscopy: a revolution in urological practice. Br J Hosp Med 70(10):583–585. https://doi.org/10.12968/hmed.2009.70.10.44626

    Article  Google Scholar 

  2. Grasso M, Beaghler M, Bagley DH, Strup S (1993) Actively deflectable, flexible cystoscopes: no longer solely a diagnostic instrument. J Endourol 7(6):527–530. https://doi.org/10.1089/end.1993.7.527

    Article  CAS  PubMed  Google Scholar 

  3. Cicione A, Cantiello F, Damiano R (2013) Cystoscopy in non-muscle-invasive bladder cancer: when and how (rigid or flexible). Urologia 80(Suppl 21):11–15. https://doi.org/10.5301/ru.2013.10858

    Article  PubMed  Google Scholar 

  4. Quayle SS, Ames CD, Lieber D, Yan Y, Landman J (2005) Comparison of optical resolution with digital and standard fiberoptic cystoscopes in an in vitro model. Urology. 66(3):489–493. https://doi.org/10.1016/j.urology.2005.04.009

    Article  PubMed  Google Scholar 

  5. Clinton TN, Lotan Y (2018) The use of blue light flexible cystoscopy with hexaminolevulinate & the diagnosis of bladder cancer. Future Oncol 14:2805–2810. https://doi.org/10.2217/fon-2018-0328

    Article  CAS  PubMed  Google Scholar 

  6. Oude Elferink P, Witjes JA (2014) Blue-light cystoscopy in the evaluation of non-muscle-invasive bladder cancer. Ther Adv Urol 6(1):25–33. https://doi.org/10.1177/1756287213510590

    Article  PubMed  PubMed Central  Google Scholar 

  7. Nkwam N, Trecarten S, Momcilovic S, Bazo A, Mann G, Sherwood B, Parkinson R (2018) Isolated red patches seen during endoscopic surveillance of bladder cancer: incidence of malignancy and when should we biopsy? J Endourol 32(4):324–327. https://doi.org/10.1089/end.2017.0744

    Article  PubMed  Google Scholar 

  8. Hermann GG, Mogensen K, Toft BG, Glenthoj A, Pedersen HM (2012) Outpatient diagnostic of bladder tumours in flexible cystoscopes: evaluation of fluorescence-guided flexible cystoscopy and bladder biopsies. Scand J Urol Nephrol 46(1):31–36. https://doi.org/10.3109/00365599.2011.637954

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jody Khan.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Ethics approval

Ethical approval was granted by the Galway University Hospitals Clinical Research Ethics Committee (Ref C.A. 2230)

Additional information

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Khan, J., Kamal, M.S., D’Arcy, F.T. et al. Biopsy at flexible cystoscopy: is it worthwhile?. Ir J Med Sci 190, 437–439 (2021). https://doi.org/10.1007/s11845-020-02284-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11845-020-02284-6

Keywords

Navigation