Skip to main content
Log in

Design and fabrication of a fully-compliant mechanism for control of cellular injection arrays

  • Assembly
  • Published:
Production Engineering Aims and scope Submit manuscript

Abstract

This paper reports on the design, fabrication, and testing of a fully-compliant mechanism designed for precise parallel guidance. The mechanism is designed to guide arrays of micro-scale needles for straight-line injections of thousands of culture cells simultaneously. During injection, the needle array is to be lowered into the cell culture dish. It must be guided carefully during insertion of the needles into the cells because any rotation or transverse motion of the needles during insertion can lead to tearing of the delicate cell membranes, leading to cell death. The injection system consists of a fully-compliant mechanism designed for straight-line motion, while resisting motions in other direction. Successive prototypes are shown to illustrate the process of design, and to illustrate the benefits of the final system. Prototypes were demonstrated using deep reactive ion etching of silicon wafers, as well as rapid prototyping using a three-dimensional printer in ABS polymer. The final system consists of a single, 3-D-printed part that incorporates compliance to guide the needle array over a distance of about 1.5 mm while restraining transverse deflections or rotations. Testing shows that injections performed using the system result in high cell viability, suggesting that the system appropriately restrains off-axis motions. While the system demonstrated here is designed specifically for biological research, it may be adapted to manufacturing, position control, or any other application requiring straight-line motion while minimizing transverse deflections or rotations.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8

Similar content being viewed by others

References

  1. Duarte RM, Howells MR, Hussain Z, Lauritzen T, McGill R, Moler EJ, Spring J (1997) A linear motion machine for soft X-ray interferometry. In: Proceedings of SPIE, optomechanical design and precision instruments 3132, San Diego, CA, USA, pp 224–232. doi:10.1117/12.279100 [online]

  2. Zhao J-S, Chu F, Feng Z-J (2008) Synthesis of rectilinear motion generating spatial mechanism with application to automotive suspension. J Mech Des Trans ASME 130(6):0650011–0650018. doi:10.1115/1.2901157 [online]

    Article  Google Scholar 

  3. Zhao J-S, Chu F, Feng Z-J, Zhao S (2009) Synthesis of a rear wheel suspension mechanism with pure rectilinear motion. J Mech Des Trans ASME 131(10):1010071–1010079. doi:10.1115/1.3179153 [online]

    Google Scholar 

  4. Seggelen J, Rosielle P, Schellekens P, Spaan H, Bergmans R, Kotte G (2005) An elastically guided machine axis with nanometer repeatability. CIRP Ann Manuf Technol 54(1):487–490

    Article  Google Scholar 

  5. Helma T, Datseris P (1986) Design of mechanisms which generate straight-line and parallel motion; robot gripper design applications. In: Proceedings of 1986 design engineering technical conferences, Columbus, OH, USA, ASME, New York, NY, USA

  6. Mehdigholi H, Akbarnejad S (2012) Optimization of watt’s six-bar linkage to generate straight and parallel leg motion. Int J Adv Robot Syst 9. doi:10.5772/50917 [online]

  7. Zhao H, Bi S, Yu J (2012) A novel compliant linear-motion mechanism based on parasitic motion compensation. Mech Mach Theory 50:15–28 [online]. doi:10.1016/j.mechmachtheory.2011.11.009

    Google Scholar 

  8. Rosenberg EJ, Radaelli G, Herder JL (2010) An energy approach to a 2d of compliant parallel mechanism with self-guiding statically-balanced straight-line behavior. In: Proceedings of ASME 2010 international design engineering technical conferences and computers and information in engineering conference 2, Montreal, QC, Canada, pp 455–464

  9. Howell LL (2001) Compliant mechanisms, Wiley, London

    Google Scholar 

  10. Aten Q, Jensen B, Tamowski S, Wilson A, Howell L, Burnett S (2012) Nanoinjection: pronuclear DNA delivery using a charged lance. Transgenic Res, pp 1–12. doi:10.1007/s11248-012-9610-6 [online]

  11. Parise JJ, Howell LL, Magleby SP (2001) Ortho-planar linear-motion springs. Mech Mach Theory 36:1281–1299

    Article  MATH  Google Scholar 

  12. Cook RD, Young WC (1999) Advanced mechanics of materials, 2nd edn, Prentice Hall, Upper Saddle River, NJ

    Google Scholar 

  13. Namazu T, Isono Y, Tanaka T (2000) Evaluation of size effect on mechanical properties of single crystal silicon by nanoscale bending test using AFM. J Microelectromech Syst 9(4):450–459

    Article  Google Scholar 

Download references

Acknowledgments

The authors thank Steve Brewer for his assistance creating and simulating the finite element model of the suspension. This work is supported by a National Science Foundation Graduate Research Fellowship (Grant No. DGE-0750759) to the first author, and by National Science Foundation Grant No. ECCS-1055916). Any opinions, findings, and conclusions or recommendations expressed in this material are those of the authors and do not necessarily reflect the views of the National Science Foundation.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Brian D. Jensen.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Teichert, G.H., Jensen, B.D. Design and fabrication of a fully-compliant mechanism for control of cellular injection arrays. Prod. Eng. Res. Devel. 7, 561–568 (2013). https://doi.org/10.1007/s11740-013-0475-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11740-013-0475-1

Keywords

Navigation