Abstract
In the present study, a sensitive and competitive chemiluminescence immunoassay (CLIA) was developed in order to detect human serum albumin (HSA) in urine specimen. The method utilizes a home-made monoclonal anti-albumin antibody conjugated to horseradish peroxidase enzyme (mAb-HRP). Sensitivity, specificity and linearity of the assay were evaluated. According to the results, the proper concentration of HSA and mAb-HRP conjugates was 800 ng/100 μl and 1:200 respectively. In optimal conditions, this method could detect HSA in a high linear range of 10–200 μg ml−1 with the low detection limit of 0.025 μg ml−1. No evidence of interference with presence of probable substances in the urine samples indicated its high specificity and selectivity. Moreover, high reproducibility as well as high sensitivity and specificity of the test were confirmed using diabetic and non-diabetic samples. Significant concordance was observed between CLIA and immunoturbidimetry assay regarding detection of HSA. The results of the present study can be considered in accordance with the current demands such as reliability, accuracy, convenience and high speed of performance for a precise protein detection method. Furthermore, it may be regarded as a more rapid, simpler and cheaper alternative compared to other sophisticated assays.
Similar content being viewed by others
References
Weir MR (2004) Microalbuminuria in type 2 diabetics: an important, overlooked cardiovascular risk factor. J Clin Hypertens 6:134–141
Gerstein HC, Mann JF, Yi Q et al (2001) Albuminuria and risk of cardiovascular events, death, and heart failure in diabetic and nondiabetic individuals. JAMA 286:421–426
Hillege HL, Janssen WM, Bak AA et al (2001) Microalbuminuria is common, also in a nondiabetic, nonhypertensive population, and an independent indicator of cardiovascular risk factors and cardiovascular morbidity. J Intern Med Jun 249(6):519–526
Hillege HL, Fidler V, Diercks GF et al (2002) Mortality in general population urinary albumin excretion predicts cardiovascular and noncardiovascular. Circulation 106(14):1777–1782
Bannett PH, Haffner S, Kaisiske BL (1995) Screening and management of microalbuminoria in patients with diabetes mellitus: recommendations to the Scientific Advisory Bord of the National Kidney Foundation from an ad hoc committee of the Council on Diabetes mellitus of the National Kidney Foundation. Am J Kidney Dis 25:107–112
Gelamo EL, Tabak M (2000) Spectrochim spectroscopic studies on the interaction of bovine (BSA) and human (HSA) serum albumins with ionic surfactants. Biophys J 56(11):2255–2271
Mogensen CE, Keane WF, Bennett PH, Striker GE, Jerums G, Parving HH, Passa P, Steffes MW, Viberti GC (1995) Prevention of diabetic renal disease with special reference to microalbuminuria. Lancet 346:1080–1084
Comper WD, Osicka TM, Jermus G (2003) High prevalence of immuno-uneractive intact albumin in urine of diabetic patients. Am J Kidney Dis 4:33–42
Owen WE, Roberts WL (2005) Performance characteristics of an HPLC assay for urinary albumin. Am J Clin Pathol 124:219–225
Sviridov D, Meilinger B, Drake SK, Hoehn GT, Hortin GL (2006) Coelution of other proteins with albumin during size-exclusion HPLC: implications for analysis of urinary albumin. Clin Chem 52:389–397
Laiwattanapaisal W, Songjaroen T, Maturos T, Lomas T, Sappat A, Tuantranont A (2009) On-Chip immunoassay for determination of urinary albumin. Sensors 9(12):10066–10079
Mohhamadnejad J, Rasaee MJ, Paknejad M, Saghafi B, Rahbarizadeh F, Omidfar K (2006) New competitive enzyme linked immunosorbent assay (MR P83-CA 15–3) for MUC1 measurement. J Immunoassay Immunochem 27:139–149
Woo J, Floyd M, Cannon DC, Kahan B (1978) Radioimmunoassay for urinary albumin. Clin Chem 24:1464–1467
Thakkar H, Newman DJ, Holownia P, Davey CL, Wang CC, Lloyd J, Craig AR, Price CP (1997) Development and validation of a particle-enhanced turbidimetric inhibition assay for urine albumin on the Dade aca analyzer. Clin Chem 43:109–113
Stamp RJ (1988) Measurement of albumin in urine by end-point immunonephelometry. Ann Clin Biochem 25:442–443
Omidfar K, Dehdast A, Zarei H, Sourkohi BK, Larijani B (2011) Development of urinary albumin immunosensor based on colloidal AuNP and PVA. Biosens Bioelectron 26(10):4177–4183
Gross JL, Azevedo MJ, Silveiro SP, Canani LH, Caramori ML, Zelmanovitz T (2005) Diabetic nephropathy: diagnosis, prevention, and treatment. Diabetes Care 28:164–176
Aoyagi S, Iwata T, Miyasaka T, Sakai K (2001) Determination of human serum albumin by chemiluminescence immunoassay with luminol using a platinum-immobilized flow-cell. Anal Chim Acta 436:103–108
Omidfar K, Khorsand B, Larijani B (2012) Development of a new sensitive immunostrip assay based on mesoporous silica and colloidal Au nanoparticles. Mol Biol Rep 39(2):1253–1259
Omidfar K, Kia S, Kashania S, Paknejad M, Besharatie A, Kashanian S, Larijani B (2010) Colloidal nanogold-based immunochromatographic strip test for the detection of digoxin toxicity. Appl Biochem Biotechnol 160(3):843–855
Pegoraro AA, Peracha W, Hasnain M, Ranginwala N, Shaykh M, Singh AK, Arruda JAL, Dunea G (2000) Evaluation of a new fluorescent dye method to measure urinary albumin in lieu of urinary total protein. Am J Kidney Dis 35:739–744
Ga′miz-Gracia L, Garcı′a-Campan˜a AM, Soto-Chinchilla JJ, Huertas-Pe′rez J, Gonza′lez-Casado A (2005) Analysis of pesticides by chemiluminescence detection in the liquid phase. Trends Anal Chem 24(11):927–942
Omidfar K, Kashanian S, Paknejad M, Kashanian S, Larijani B, Roshanfekr H (2007) Production and characterization of monoclonal antibody against human serum albumin. Hybridoma 26:217–222
Horton JK, Davies M, Woodhead JS, Weeks I (1989) A rapid and sensitive method for estimating low concentrations of albumin in human urine. Clin Chim Acta 186:45–51
Bagazgoitia FJ, Garcia JL, Ibarra JM, Patiño R, Diéquez C, Weeks I, Woodhead JS (1989) Chemiluminescent immunoassay (CLIA) for urinary albumin. J Biolumin Chemilumin 3(4):169–174
Omidfar K, Rasaee MJ, Zaraee AB, Amir MP, Rahbarizadeh F (2002) Stabilization of penicillinase–hapten conjugate for enzyme immunoassay. J Immunoassay Immunochem 23:385–398
Acknowledgments
This research has been supported by the Endocrinology Metabolism Research Center of Tehran University of Medical Sciences, Tehran, and I.R. Iran.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Meibodi, E.S.A., Azizi, M.D., Paknejad, M. et al. Development of an enhanced chemiluminescence immunoassay (CLIA) for detecting urinary albumin. Mol Biol Rep 39, 10851–10858 (2012). https://doi.org/10.1007/s11033-012-1981-5
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11033-012-1981-5