Abstract

Purpose

To evaluate the relationship of tear osmolarity (TO) with tear meniscus curvature and contact angles by anterior segment optical coherence tomography (AS-OCT) in healthy subjects.

Methods

The right eyes of 64 consecutive healthy subjects were included in the study. The eyes were scanned by AS-OCT for the measurements of upper and lower tear menisci. The geometrical components of the upper and lower menisci, including height, depth, area, and radius of the menisci, cornea-meniscus angle (α-angle), meniscus-eyelid angle (β-angle), and curvature angle (θ-angle) were measured. TO was obtained by TearLab. All participants were administered Ocular Surface Disease Index questionnaires (OSDI), and tear film break-up time (TBUT), Schirmer I and II test measurements were also performed.

Results

There was no association of TO with height, depth, and area of both menisci while TO was negatively correlated to θ-angle and radius of the lower eyelid meniscus (r = − 0.41, P < 0.001 and r = − 0.40, P < 0.01, respectively). The θ-angle and the radius of the lower meniscus were also significantly associated with OSDI score, TBUT, Schirmer I and II (P < 0.01 for all). There was a statistically strong correlation between the θ-angle and the radius of the lower meniscus (r = 0.91, P < 0.001).

Conclusion

The curvature angle and radius of the lower meniscus are significantly associated with TO. The curvature angle of the lower meniscus is a useful non-contact measure that may provide information indirectly about the osmolarity and the quality of the tear.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Tomlinson A, Khanal S, Ramaesh K, Diaper C, McFadyen A (2006) Tear film osmolarity: determination of a referent for dry eye diagnosis. Invest Ophthalmol Vis Sci 47:4309–4315. https://doi.org/10.1167/iovs.05-1504

    Article  PubMed  Google Scholar 

  2. Baenninger PB, Voegeli S, Bachmann LM, Faes L, Iselin K, Kaufmann C, Thiel MA (2018) Variability of tear osmolarity measurements with a point-of-care system in healthy subjects-systematic review. Cornea 37:938–945. https://doi.org/10.1097/ICO.0000000000001562

    Article  PubMed  Google Scholar 

  3. Tomlinson A, McCann LC, Pearce EI (2010) Comparison of human tear film osmolarity measured by electrical impedance and freezing point depression techniques. Cornea 29:1036–1041. https://doi.org/10.1097/ICO.0b013e3181cd9a1d

    Article  PubMed  Google Scholar 

  4. Czajkowski G, Kaluzny BJ, Laudencka A, Malukiewicz G, Kaluzny JJ (2012) Tear meniscus measurement by spectral optical coherence tomography. Optom Vis Sci 89:336–342. https://doi.org/10.1097/OPX.0b013e318242042b

    Article  PubMed  Google Scholar 

  5. Fukuda R, Usui T, Miyai T, Yamagami S, Amano S (2013) Tear meniscus evaluation by anterior segment swept-source optical coherence tomography. Am J Ophthalmol 155:620-e621. https://doi.org/10.1016/j.ajo.2012.11.009

    Article  PubMed  Google Scholar 

  6. Zhou S, Li Y, Lu AT, Liu P, Tang M, Yiu SC, Huang D (2009) Reproducibility of tear meniscus measurement by Fourier-domain optical coherence tomography: a pilot study. Ophthalmic Surg Lasers Imaging 40:442–447. https://doi.org/10.3928/15428877-20090901-01

    Article  PubMed  PubMed Central  Google Scholar 

  7. Yokoi N, Bron AJ, Tiffany JM, Kinoshita S (2000) Reflective meniscometry: a new field of dry eye assessment. Cornea 19:S37-43. https://doi.org/10.1097/00003226-200005001-00008

    Article  CAS  PubMed  Google Scholar 

  8. Oguz H, Yokoi N, Kinoshita S (2000) The height and radius of the tear meniscus and methods for examining these parameters. Cornea 19:497–500. https://doi.org/10.1097/00003226-200007000-00019

    Article  CAS  PubMed  Google Scholar 

  9. Shen M, Li J, Wang J, Ma H, Cai C, Tao A, Yuan Y, Lu F (2009) Upper and lower tear menisci in the diagnosis of dry eye. Invest Ophthalmol Vis Sci 50:2722–2726. https://doi.org/10.1167/iovs.08-2704

    Article  PubMed  Google Scholar 

  10. Napoli PE, Satta GM, Coronella F, Fossarello M (2014) Spectral-domain optical coherence tomography study on dynamic changes of human tears after instillation of artificial tears. Invest Ophthalmol Vis Sci 55:4533–4540. https://doi.org/10.1167/iovs.14-14666

    Article  PubMed  Google Scholar 

  11. Bandlitz S, Purslow C, Murphy PJ, Pult H (2014) Comparison of a new portable digital meniscometer and optical coherence tomography in tear meniscus radius measurement. Acta Ophthalmol 92:e112-118. https://doi.org/10.1111/aos.12275

    Article  PubMed  Google Scholar 

  12. Bandlitz S, Purslow C, Murphy PJ, Pult H (2014) Time course of changes in tear meniscus radius and blink rate after instillation of artificial tears. Invest Ophthalmol Vis Sci 55:5842–5847. https://doi.org/10.1167/iovs.14-14844

    Article  PubMed  Google Scholar 

  13. Yokoi N, Bron AJ, Tiffany JM, Maruyama K, Komuro A, Kinoshita S (2004) Relationship between tear volume and tear meniscus curvature. Arch Ophthalmol 122:1265–1269. https://doi.org/10.1001/archopht.122.9.1265

    Article  PubMed  Google Scholar 

  14. Siebold A, Walliser A, Nardin M, Oppliger M, Schultz J (1997) Capillary rise for thermodynamic characterization of solid particle surface. J Colloid Interface Sci 186:60–70. https://doi.org/10.1006/jcis.1996.4640

    Article  CAS  PubMed  Google Scholar 

  15. Souza AC, Zatz R, de Oliveira RB, Santinho MA, Ribalta M, Romao JE Jr, Elias RM (2015) Is urinary density an adequate predictor of urinary osmolality? BMC Nephrol 16:46. https://doi.org/10.1186/s12882-015-0038-0

    Article  PubMed  PubMed Central  Google Scholar 

  16. Uzunosmanoglu E, Mocan MC, Kocabeyoglu S, Karakaya J, Irkec M (2016) Meibomian gland dysfunction in patients receiving long-term glaucoma medications. Cornea 35:1112–1116. https://doi.org/10.1097/ICO.0000000000000838

    Article  PubMed  Google Scholar 

  17. Doguizi S, Sekeroglu MA, Inanc M, Yilmazbas P (2019) Evaluation of tear meniscus dimensions using anterior segment optical coherence tomography in video terminal display workers. Clin Exp Optom 102:478–484. https://doi.org/10.1111/cxo.12872

    Article  PubMed  Google Scholar 

  18. Stahl U, Willcox M, Stapleton F (2012) Osmolality and tear film dynamics. Clin Exp Optom 95:3–11. https://doi.org/10.1111/j.1444-0938.2011.00634.x

    Article  PubMed  Google Scholar 

  19. Li M, Du C, Zhu D, Shen M, Cui L, Wang J (2012) Daytime variations of tear osmolarity and tear meniscus volume. Eye Contact Lens 38:282–287. https://doi.org/10.1097/ICL.0b013e31825fed57

    Article  PubMed  PubMed Central  Google Scholar 

  20. Gaffney EA, Tiffany JM, Yokoi N, Bron AJ (2010) A mass and solute balance model for tear volume and osmolarity in the normal and the dry eye. Prog Retin Eye Res 29:59–78. https://doi.org/10.1016/j.preteyeres.2009.11.002

    Article  CAS  PubMed  Google Scholar 

  21. Savini G, Barboni P, Zanini M (2006) Tear meniscus evaluation by optical coherence tomography. Ophthalmic Surg Lasers Imaging 37:112–118

    Article  Google Scholar 

  22. Li J, Shen M, Wang J, Ma H, Tao A, Xu S, Lu F (2012) Clinical significance of tear menisci in dry eye. Eye Contact Lens 38:183–187. https://doi.org/10.1097/ICL.0b013e318252ce0c

    Article  PubMed  Google Scholar 

  23. Garcia-Resua C, Pena-Verdeal H, Remeseiro B, Giraldez MJ, Yebra-Pimentel E (2014) Correlation between tear osmolarity and tear meniscus. Optom Vis Sci 91:1419–1429. https://doi.org/10.1097/OPX.0000000000000412

    Article  PubMed  Google Scholar 

  24. Tukenmez-Dikmen N, Yildiz EH, Imamoglu S, Turan-Vural E, Sevim MS (2016) Correlation of dry eye workshop dry eye severity grading system with tear meniscus measurement by optical coherence tomography and tear osmolarity. Eye Contact Lens 42:153–157. https://doi.org/10.1097/ICL.0000000000000168

    Article  PubMed  Google Scholar 

  25. Zhang L, Sun X, Yu Y, Xiong Y, Cui Y, Wang Q, Hu L (2016) The correlations between corneal sensation, tear meniscus volume, and tear film osmolarity after femtosecond laser-assisted LASIK. Zhonghua Yan Ke Za Zhi 52:30–35. https://doi.org/10.3760/cma.j.issn.0412-4081.2016.01.009

    Article  PubMed  Google Scholar 

  26. Yokoi N, Kato H, Kinoshita S (2014) Facilitation of tear fluid secretion by 3% diquafosol ophthalmic solution in normal human eyes. Am J Ophthalmol 157(85–92):e81. https://doi.org/10.1016/j.ajo.2013.09.009

    Article  CAS  Google Scholar 

  27. Wang J, Simmons P, Aquavella J, Vehige J, Palakuru J, Chung S, Feng C (2008) Dynamic distribution of artificial tears on the ocular surface. Arch Ophthalmol 126:619–625. https://doi.org/10.1001/archopht.126.5.619

    Article  PubMed  Google Scholar 

  28. Montero de Hijes P, Shi K, Noya EG, Santiso EE, Gubbins KE, Sanz E, Vega C (2020) The Young-Laplace equation for a solid-liquid interface. J Chem Phys 153:191102. https://doi.org/10.1063/5.0032602

    Article  CAS  PubMed  Google Scholar 

  29. Wang J, Palakuru JR, Aquavella JV (2008) Correlations among upper and lower tear menisci, noninvasive tear break-up time, and the Schirmer test. Am J Ophthalmol 145:795–800. https://doi.org/10.1016/j.ajo.2007.12.035

    Article  PubMed  PubMed Central  Google Scholar 

  30. Wang J, Aquavella J, Palakuru J, Chung S, Feng C (2006) Relationships between central tear film thickness and tear menisci of the upper and lower eyelids. Invest Ophthalmol Vis Sci 47:4349–4355. https://doi.org/10.1167/iovs.05-1654

    Article  PubMed  Google Scholar 

  31. Sarac O, Soyugelen G, Gurdal C, Bostanci-Ceran B, Can I (2011) Tear meniscus analysis with Fourier-domain optical coherence tomography in keratoconus. Curr Eye Res 36:528–533. https://doi.org/10.3109/02713683.2011.569869

    Article  PubMed  Google Scholar 

Download references

Funding

There is no received funding for this work.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Volkan Yeter.

Ethics declarations

Conflict of interest

The authors have no financial interest or disclosures.

Ethical approval

All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 declaration of HELSINKI and its later amendments or comparable ethical standards.

Informed consent

Informed consent was obtained from all individual participants included in the study.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Yeter, V., Koçak, N., Kalyoncu, M. et al. The relationship of tear osmolarity with tear meniscus curvature and contact angles in healthy subjects: anterior segment optical coherence tomography study. Int Ophthalmol 42, 261–268 (2022). https://doi.org/10.1007/s10792-021-02022-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10792-021-02022-6

Keywords

Navigation