Abstract
Conventional activated sludge system is confidently widely used for biological treatment plants of municipal wastewater but suffering from operation problems that affect their efficiencies and effluent qualities, especially when treating low-strength wastewater with increasing incoming flow. The objective of this study is to evaluate and compare the novel methods used in upgrading conventional activated sludge treatment systems receiving low-strength wastewater to generate good effluent quality. GPS-X Simulator V 8.0 was used for model calibration and plant performance prediction. The calibrated GPS-X model proved that eliminating primary settling from the treatment process does not affect BOD5 and COD removal, while TSS removal is decreased, and NH4-N removal is increased. Increasing the return activated sludge flow from 50 to 150% of influent flow does not affect conventional activated sludge process, while the change of waste activated flow had a vital effect on process performance. The presence of an anoxic zone in conventional activated sludge processes treating low-strength wastewater has no significant impact on plant performance. Also, the model outputs proved that adding filling media to the aeration tank was able to handle an increase of influent flow and a stable performance of BOD5, and NH4-N removal was observed.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
Increasing water supply services in developing countries doesn’t meet development in sanitation services, and most of this water directly discharges to water bodies with insufficient or without treatment (Ren et al., 2010). Egypt is suffering from a lack of sanitation services, and most of the generated sewage is directed to surface water bodies (Nasr et al., 2011; States & utvecklingssamarbete, 2013). Egypt issued law 48/1982 and its amendments to regulate the disposal of treated wastewater in the different water bodies (Abdel-Dayem, 2011). Egypt has large centralized wastewater treatment plants (WWTPs) in greater Cairo, ranging from 330,000 m3/day in Zenien to 2.5 million m3/day in Al-Gabal Al-Asfar, and most of these plants are conventional activated sludge systems (CAS) (Darling & Drake, 1985). The WWTPs are suffering from operation and design problems that affect efficiencies and effluent qualities and do not comply with Egyptian regulations (Wang et al., 2012). All of these WWTPs transfer treated water to surface used water bodies and cause environmental and human health concerns due to the usage of these water (Focazio et al., 2008; Pham & Utsumi, 2018).
The wastewater was characterized as low, medium, and high strength according to the level of contaminations, expressed as chemical oxygen demand, biological oxygen demand, and suspended solids (Metcalf & Eddy, 2014). The municipal wastewater in all of these WWTPs is characterized as medium to low-strength wastewater.
Biological treatment systems have been used for wastewater treatment; conventional activated sludge system confidently is reliably widely used for the biological treatment of municipal wastewater (Hreiz et al., 2015). Sludge bulking was a problem found when treating low-strength wastewater by conventional activated sludge, the low substrate cause sludge flocculent, and predominate filamentous bacteria to cause the sludge bulking phenomenon (Jenkins et al., 2003; Martins et al., 2004; Wei et al., 2015). The major problem in an activated sludge system treating low organic matter concentration is low biomass concentration and poor biomass floc formation in aeration tank, due to insufficient carbonaceous matter for bacterial growth, which leads to a decrease in the removal organic efficiency (Thirumurthi & Orlando, 1976). Also, these WWTPs continuously receive a gradual annual increased incoming flow and contribute to the deterioration of WWTP treated effluents qualities.
The new aerobic granular sludge technology has been used to treat low-strength wastewater (Pronk et al., 2017). Granular aerobic sludge technology, compared with conventional activated sludge, has a compact microbial spherical shape structure, high stability, less sludge production, and good settling ability (Wei et al., 2013). In spite of the advantages of aerobic granular technology, shortage and complexity of substrate associated with low wastewater cause undesirable granular biomass growth. Also, limited research was applied to treat low wastewater, especially in a full-scale plant using aerobic granular technology yet (We et al., 2020). Using granular aerobic sludge technology in existing conventional activated sludge plants is facing the squandering of putting aside both primary and final settling tanks, in addition to the small size of the aeration basin, which isn’t valid to longer operation in sequencing batch reactor mode (Nancharaiah & Reddy, 2018).
Anaerobic wastewater treatment process has been used in treatment of low-strength wastewater (Angenent et al., 2001). The anaerobic treatment systems don’t achieve the desired quality of treatment alone, especially when used for low-strength wastewater treatment (Rodrigues et al., 2001). The problem of odor and clogging associated with anaerobic systems is reducing the tendency to use these technologies especially in inhabited regions and large-scale plants (Manariotis & Grigoropoulos, 2002).
According to the issues stated before, it is needed to develop a novel treatment method applicable in conventional activated sludge system. Mathematical modeling becomes popular in design and simulating the wastewater treatment plant process (Copp et al., 2009). The modeling can easily predict system treatment performance (Ai et al., 2012; Pereira, 2014). So, the objective of this study is to evaluate and compare the novel methods that are used in upgrading conventional activated sludge treatment systems receiving low-strength wastewater to generate good effluent quality comply with environmental regulation and reduce pollution load in the receiving water bodies.
Materials and methods
Zenien conventional activated sludge wastewater treatment plant description
The existing Zenien WWTP is a conventional activated sludge system. As shown in Fig. 1 and abridged in Table 1, Zenien WWTP consists of preliminary headworks and three modules for primary and secondary biological treatment; each module consists of four circle primary settling tanks followed by thirty rectangular aeration tanks and then four final settling tanks and contains a return activated pump station. The treated wastewater from all final sedimentation tanks goes towards one chlorine tank and then disposed to agricultural drain, while primary sludge and excess sludge from each module are pumped to one pump station in the plant, which transfers the sludge to handle and dispose it outside, at desert region.
Zenien WWTP is located in Giza governorate, Egypt. Zenien WWTP is constructed in the year 1965 on 96 acres, The design capacity of Zenien WWTP was 330,000 m3/day. Now Zenien WWTP receives a flow of 275,000 to 550,000 m3/day with an average flow (Q) of 385,000 m3/day.
Wastewater characteristics
The influent and effluent wastewater samples of Zenien municipal WWTP were collected and characterized daily using plant lab staff. The samples were taken from the inlet chamber, final effluent channel, primary settling tank effluent, and final settling tank effluent. The influent and effluent samples were analyzed for total suspended solid (TSS), total chemical oxygen demand (COD), total biochemical oxygen demand (BOD5), and ammonia (NH4-N). Sludge samples were collected from aeration tanks of three modules for mixed liquor suspended solid (MLSS), mixed liquor volatile suspended solid (MLVSS), and sludge volume index (SVI) measurements. All parameters were measured according to Standard Methods for the Examination of Water and Wastewater (APHA, 2005). Tables 2 to 4 summarize the wastewater average concentration parameters of inlet and outlet processes units in Zenien municipal WWTP. Zenien plant influent wastewater is considered as a low-strength wastewater, where COD, BOD5, and TSS concentrations conform to Metcalf and Eddy, (2014) as low-strength wastewater.
This research used the historical wastewater analysis data of Zenien WWTP full-scale conventional activated sludge system, Giza, Egypt, from January to November 2019.
Modeling Zenien WWTP using GPS-X simulator
Mathematical models were developed to simulate treatment processes in WWTPs and to predict the performance of these plants under different operating conditions (Gernaey et al., 2004; Ji et al., 2019). Various authors use commercial modeling software to study activated sludge wastewater treatment plants, for instance (Abbasi et al., 2021; Latif et al., 2020; Pereira, 2014; Rivas et al., 2008). GPS-X simulator V 8.0 (Hydromantis Environmental Software Solutions, Inc., Canada) is one of the popular modeling software that contains IWA’s activated sludge models and Hydromantis’s models (Hydromantis, 2019). The simulation of Zenien conventional activated sludge WWTP was conducted using GPS-X Simulator V 8.0 with the help of GPS-X manuals.
Zenien WWTP model construction in GPS-X was based on the plant’s real municipal wastewater characteristics and actual operation data presented previously for 11 months. The model as shown in Fig. 2 consists of raw influent wastewater, primary settling tank, aeration tank, final settling tank, and treated wastewater effluent blocks. The plant flow was divided by twelve to simulate one primary and final sedimentation tank, while this ratio was converted to be used in one aeration tank dimensions. The influent block was used for raw wastewater characteristics; the physical dimensions and operation condition of the plant were assigned as actual plant data in primary, final sedimentation tanks, and aeration tanks, while the effluent block represented treated wastewater outfall. The biological model used to simulate the Zenien WWTP was Hydromantis’s Mantis2, which was used for the organic and nutrient simulation process (Hydromantis, 2019), and the simulation results were obtained using a default kinetics parameter of the model.
Calibration and validation of GPS-X model
The simulation results of Zenien WWTP model in GPS-X were compared with the actual plant results in Tables 2, 3, and 4. The GPS-X Zenien model was calibrated and validated to allow the simulated results to fit the actual plant results (Abou-Elela et al., 2016), in which the reliance was 95%, using one-way ANOVA statistical between real and simulated results (Mu’azu et al., 2020).
Applying novel treatment methods in Zenien conventional activated sludge plant
Calibrated GPS-X model of Zenien CAS WWTP was used for applying a novel treatment method for studying and enhancement of plant performance. Through the calibrated model, GPS-X was used to create five scenarios: (a) bypassing primary settling from plant process, (b) effect of return activated sludge (Qr) and waste sludge (Qw) flows, (c) effect of anoxic/oxic (A/O) zones, (d) effect of adding media to the aeration tank; and (e) effect of increasing influent flow.
Results and discussions
Zenien CAS WWTP model calibration and validation
The simulation results of Zenien WWTP model using GPS-X simulator were obtained by default kinetics parameter of the model; we found that the simulation results are different from the real plant result effluents in terms of COD, BOD5, and NH4-N; thus, the model calibration was essential.
The most sensitive kinetic parameters of the biological model were investigated by the researchers, Latif et al. (2020) who found a change of aerobic heterotrophic yield (YH) and aerobic heterotrophic decay rate (bH) values, which affect the model in terms of COD and BOD5 effluent concentrations; change maximum growth rate for ammonia oxidizer (μA), ammonia oxidizer aerobic decay rate (bA), and oxygen saturation for ammonia oxidizer (KO) values; and affect the model in term NH4-N effluent concentration. Moretti et al. (2018) found (μA), (bA), and (KO) were most sensitive model parameter for ammonia removal. Liwarska-Bizukojc et al. (2011) found (μA), (bA), and (KO); substrate (NH4-N) half-saturation constant (KNH4); maximum growth rate of heterotrophic organisms (μH); and substrate (COD) half-saturation constant (KS), (bH), and (YH) were sensitively model parameters for COD, BOD5, and NH4-N removals. Hu et al. (2014) found (μH), (YH) (KS), (bH), (μA), (KNH4), and (bA) were sensitive parameters related to COD and NH4-N effluent concentrations.
The used Hydromantis’s Mantis2 model contains over 50 kinetic and stoichiometric parameters. In order to conduct sensitivity analysis in GPS-X simulator for the determination of sensitive parameters that will be used for model calibration, it will take a long time so, based on the most sensitive parameters that were found in the literature (μH, YH, bH, μA, KO, bA, and KNH4) which were considered sensitively acceptable parameters used in model calibration.
Model calibration and validation in GPS-X simulator were performed by adjusting model kinetic parameters; Table 5 shows kinetic parameters (default, adjusted, and reported in the literature) values. Figure 3 shows an average effluent concentration of real plant results versus calibrated model results, where the model results fit with real plant results in terms of TSS, BOD5, COD, and NH4-N effluent concentrations. The results demonstrate validation of the model comparing with real plant results through eleven months, which no significant difference between simulated and real results for TSS, BOD5, COD, and NH4-N effluent concentrations (Petersen et al., 2003).
Applying novel treatment methods in Zenien conventional activated sludge plant
Bypassing primary settling from plant process scenario
Bypassing primary settling from the plant process scenario was simulated using the calibrated model to predict and test the plant performance without primary settling. Figure 4 shows the flow diagram of bypassing primary settling from plant process scenario in GPS-X simulator. Figure 5 shows effluent concentrations of TSS, BOD5, COD, and NH4-N corresponding to removal efficiency of 74.3, 89, 78.3, and 78.3%, respectively, in case of plant without primary settling and no significant difference between removal efficiency for BOD5 and COD with and without primary settling, in which the average removal efficiency of BOD5 and COD was 88.4 and 83.7% at real record results of plant with primary settling. TSS removal efficiency decreased from 86.6 to 74.3% and NH4-N removal efficiency increased from 52.5 to 78.3%, clearly significant between with and without primary settling scenarios. The decrease of TSS removal may be ascribed to the elimination of primary settling, while the increase of ammonia removal may be ascribed to increase nitrifier bacteria, due to an increase of biomass concentration in aeration tank with the elimination of primary settling (Gerardi, 2011).
Effect of return activated sludge and excess sludge flows scenario
A study of the effect of return activated sludge and excess sludge flows scenario was carried out also without primary settling using the same flow diagram shown in Fig. 4. Figure 6 shows the effect of return activated sludge percent in terms of TSS, BOD5, COD, and NH4-N effluent concentrations. The simulation results of this scenario proved that no significant difference between TSS, BOD5, COD, and NH4-N effluent concentration with the change of return activated sludge percentage between 0.25 and 1.5 of influent flow, except ammonia at 0.25 value, which has a significant removal decrease than other values, and this could be ascribed to lower nitrifier bacteria concentration at 0.25 value than other values. The Qr/Q of 0.5 is considered optimum from the economic view.
Study of the effect of waste sludge flow scenario was carried out also without primary settling at 50% return activated sludge flow. The waste sludge flows were 50, 100, 150, 200, 250, 300, 350, and 400 m3/day corresponding to (Qw/Qr) of 0.31, 0.63, 0.94, 1.25, 1.56, 1.88, 2.19, and 2.5% and SRT of 16, 15, 14, 12, 11, 9, 8, and 7 days, respectively.
Figure 7 shows the effect of waste sludge flow in terms of TSS, BOD5, COD, and NH4-N effluent concentrations. The simulation results of this scenario proved that variation of waste sludge between 50 and 400 m3/day doesn’t significantly affect BOD5 removal.
Increased waste flow from 50 to 200 m3/day significantly improved COD and TSS removal, where no significant effect was observed when waste flow increased up to 400 m3/day.
Increased waste flow from 50 to 200 m3/day does not significantly affect NH4-N removal, while increasing the waste flow to 400 m3/day significantly decreases NH4-N removal.
The optimum value for excess sludge flow is considered 200 m3/day with regard to the economic and removal view.
Effect of introducing anoxic zone scenario
The effect of introducing an anoxic zone with internal recycling on conventional activated sludge process was tested using calibrated GPS-X model. Figure 8 shows the flow diagram of anoxic/oxic zones scenario in GPS-X simulator. Primary settling was bypassed, internal recycle was 200% of influent flow, the anoxic zone was 25% of aeration tank volume, waste sludge flow was 200 m3/day, and return activated sludge percent was 50% of the influent flow.
Figure 9 shows effluent concentrations of TSS, BOD5, COD, and NH4-N; the results prove no significant removal rate between removal efficiency for BOD5 and COD with and without the anoxic zone in case of bypassing primary settling, while TSS removal efficiency significantly increased, and NH4-N removal efficiency significantly decreased. It is concluded that introducing an anoxic zone to the conventional activated sludge process improves TSS, BOD5, and COD removal and slightly decreases the NH4-N removal in case of bypassing primary settling and no significant impact TSS, BOD5, and COD removal in case of existing the primary settling.
Effect of filling media scenario
The effect of filling aeration tank with plastic media was investigated using calibrated GPS-X model. Primary settling was bypassed, waste sludge was 200 m3/day, return activated sludge percent was 50% of influent flow, the filling ratio was 50% of aeration tank volume, and media surface area was 500 m2/m3. Figure 10 shows the flow diagram of aeration tank with filling media scenario in GPS-X simulator.
Figure 11 shows effluent concentrations of TSS, BOD5, COD, and NH4-N; the results prove no significant difference between removal efficiency for BOD5 and COD with and without filling media in case of bypassing primary settling, while TSS and NH4-N removal efficiency significantly increased. It is concluded that adding filling media to aeration tank of conventional activated sludge process significantly improves NH4-N removal.
Effect of increasing influent flow scenario
The effect of increasing influent on aeration tank was investigated as shown in Figs. 12, 13; the influent flow was increased from 100 to 200%, applying to aeration tank in the previous scenarios (with and without adding media) using the same flow diagram shown in Fig. 10. It was proved, as shown in Fig. 12, that increasing influent flow from 125 to 200% significantly decreases removal of TSS, BOD5, COD, and NH4-N, and this decrease is ascribed to low hydraulic retention time with the increasing influent flow (Aghapour et al., 2013; Sirianuntapiboon et al., 2005). As shown in Fig. 13, it was proved that increasing influent flow had no significant effect in terms of BOD5 and NH4-N removal; this may be ascribed to the activity of biomass attached to the media in aeration tank that supports the addition of both heterotrophic and nitrifier bacteria (Randall & Sen, 1996; Sirianuntapiboon & Yommee, 2006), but a significant effect in terms of TSS and COD removal was observed, and this could be ascribed to complex degradation of low-strength substrate (Mannina et al., 2017).
Conclusions
-
The calibrated GPS-X model was used to predict the effect of eliminating primary settling from conventional activated sludge process when treating low-strength wastewater. The model outputs proved that eliminating primary settling from the treatment process did not affect BOD5 and COD removal, while TSS removal is decreased, and NH4-N removal is increased.
-
The model outputs proved that increasing the return activated sludge flow from 50 to 150 of influent flow didn’t affect conventional activated sludge process, while change waste activated flow had a vital effect on process performance.
-
The model outputs proved that the presence of anoxic phase in conventional activated sludge process treating low-strength wastewater has no significant impact on plant performance
-
The model outputs proved that adding filling media to the aeration tank in conventional activated sludge process treating low-strength wastewater will enable to handle increase influent flow with stable performance for BOD5 and NH4-N removal, as was observed, rather than the system without media.
Data availability
All data analyzed during this study are included in this article. The raw data that support the findings of this study are available on request from the author.
Change history
24 June 2024
A Correction to this paper has been published: https://doi.org/10.1007/s10661-024-12828-3
References
Abbasi, N., Ahmadi, M., & Naseri, M. (2021). Quality and cost analysis of a wastewater treatment plant using GPS-X and CapdetWorks simulation programs. Journal of Environmental Management, 284, 111993.
Abdel-Dayem, S. (2011). Water quality management in Egypt. International Journal of Water Resources Development, 27(1), 181–202.
Abou-Elela, S. I., Hamdy, O., & El Monayeri, O. (2016). Modeling and simulation of hybrid anaerobic/aerobic wastewater treatment system. International Journal of Environmental Science and Technology, 13(5), 1289–1298.
Afonso, P., & da Conceição Cunha, M. (2002). Assessing parameter identifiability of activated sludge model number 1. Journal of Environmental Engineering, 128(8), 748–754.
Aghapour, A. A., Moussavi, G., & Yaghmaeian, K. (2013). Biological degradation of catechol in wastewater using the sequencing continuous-inflow reactor (SCR). Journal of Environmental Health Science and Engineering, 11(1), 1–10.
Ai, H. N., Li, M. L., & He, Q. (2012). Simulation and optimization of denitrifying phosphorus removal in A2/O. Advanced Materials Research, 374, 553–559.
Angenent, L. T., Banik, G. C., & Sung, S. (2001). Anaerobic migrating blanket reactor treatment of low-strength wastewater at low temperatures. Water Environment Research, 73(5), 567–574.
A. P. H. A., Federation, W. E., & Association, A. P. H. (2005). Standard methods for the examination of water and wastewater. American Public Health Association (APHA).
Boontian, N. (2012). A calibration approach towards reducing ASM2d parameter subsets in phosphorus removal processes. World Academy of Science, Engineering and Technology, 64, 984–990.
Copp, J. B., Johnson, B. R., Shaw, A., Burbano, M. S., Narayanan, B., Frank, K., Kinnear, D., Melcer, H., & Brischke, K. (2009). A balancing act: The consulting engineers’ pragmatic view of process modelling. Water Science and Technology, 59(4), 763–769.
Darling, R. S., & Drake, J. (1985). Greater Cairo wastewater project: Studies and master plan. Proceedings of the Institution of Civil Engineers, 78(4), 745–763.
Focazio, M. J., Kolpin, D. W., Barnes, K. K., Furlong, E. T., Meyer, M. T., Zaugg, S. D., Barber, L. B., & Thurman, M. E. (2008). A national reconnaissance for pharmaceuticals and other organic wastewater contaminants in the United States—II) Untreated drinking water sources. Science of the Total Environment, 402(2–3), 201–216.
Gerardi, M. H. (2011). Troubleshooting the sequencing batch reactor (Vol. 11). John Wiley & Sons.
Gernaey, K. V., van Loosdrecht, M. C. M., Henze, M., Lind, M., & Jørgensen, S. B. (2004). Activated sludge wastewater treatment plant modelling and simulation: State of the art. Environmental Modelling & Software, 19(9), 763–783.
Hreiz, R., Latifi, M. A., & Roche, N. (2015). Optimal design and operation of activated sludge processes: State-of-the-art. Chemical Engineering Journal, 281, 900–920.
Hu, X., Xie, L., Mi, C., & Yang, D. (2014). Calibration and validation of an activated sludge model for a pilot-scale anoxic/anaerobic/aerobic/post-anoxic process. Journal of Zhejiang University SCIENCE A, 15(9), 743–752.
Hydromantis. (2019). Inc., GPS-X Technical Reference, Hydromantis, Inc., Consulting Engineers: Hamilton, ON, Canada. Inc.: Hamilton, ON, Canada.
Jenkins, D., Richard, M. G., & Daigger, G. T. (2003). Manual on the causes and control of activated sludge bulking, foaming, and other solids separation problems. Crc Press.
Jeppsson, U. (1996). Modelling aspects of wastewater treatment processes. Lund Institute of Technology Sweden.
Ji, X., Liu, Y., Zhang, J., Huang, D., Zhou, P., & Zheng, Z. (2019). Development of model simulation based on BioWin and dynamic analyses on advanced nitrate nitrogen removal in deep bed denitrification filter. Bioprocess and Biosystems Engineering, 42(2), 199–212.
Latif, E. F., Elmolla, E. S., Mahmoud, U. F., & Saleh, M. M. (2020). Intermittent cycle extended aeration system pilot scale (ICEAS-PS) for wastewater treatment: Experimental results and process simulation. International Journal of Environmental Science and Technology, 17(6), 3261–3270.
Liwarska-Bizukojc, E., Olejnik, D., Biernacki, R., & Ledakowicz, S. (2011). Calibration of a complex activated sludge model for the full-scale wastewater treatment plant. Bioprocess and Biosystems Engineering, 34(6), 659–670.
Manariotis, I. D., & Grigoropoulos, S. G. (2002). Low-strength wastewater treatment using an anaerobic baffled reactor. Water Environment Research, 74(2), 170–176.
Mannina, G., Capodici, M., Cosenza, A., Cina, P., Di Trapani, D., Puglia, A. M., & Ekama, G. A. (2017). Bacterial community structure and removal performances in IFAS-MBRs: A pilot plant case study. Journal of Environmental Management, 198, 122–131.
Martins, A. M. P., Pagilla, K., Heijnen, J. J., & van Loosdrecht, M. C. M. (2004). Filamentous bulking sludge—A critical review. Water Research, 38(4), 793–817.
Metcalf & Eddy, Abu-Orf, M., Bowden, G., Pfrang, W., & Tchobanoglous, G. (2014). Wastewater engineering: Treatment and resource recovery. McGraw-Hill Education.
Moretti, P., Choubert, J.-M., Canler, J.-P., Buffière, P., Pétrimaux, O., & Lessard, P. (2018). Dynamic modeling of nitrogen removal for a three-stage integrated fixed-film activated sludge process treating municipal wastewater. Bioprocess and Biosystems Engineering, 41(2), 237–247.
Mu’azu, N. D., Alagha, O., & Anil, I. (2020). Systematic modeling of municipal wastewater activated sludge process and treatment plant capacity analysis using GPS-X. Sustainability, 12(19), 8182.
Mulas, M. (2006). Modelling and control of activated sludge processes. Università Degli Studi Di Cagliari.
Nancharaiah, Y. V., & Reddy, G. K. K. (2018). Aerobic granular sludge technology: Mechanisms of granulation and biotechnological applications. Bioresource Technology, 247, 1128–1143.
Nasr, M. S., Moustafa, M. A. E., Seif, H. A. E., & El Kobrosy, G. (2011). Modelling and simulation of German BIOGEST/EL-AGAMY wastewater treatment plants–Egypt using GPS-X simulator. Alexandria Engineering Journal, 50(4), 351–357.
Pereira, S. F. (2014). Modelling of a wastewater treatment plant using GPS-X. Faculdade de Ciências e Tecnologia.
Petersen, B., Gernaey, K., Henze, M., & Vanrolleghem, P. A. (2003). Calibration of activated sludge models: A critical review of experimental designs. Biotechnology for the Environment: Wastewater Treatment and Modeling, Waste Gas Handling, 101–186.
Pham, T.-L., & Utsumi, M. (2018). An overview of the accumulation of microcystins in aquatic ecosystems. Journal of Environmental Management, 213, 520–529.
Pronk, M., Giesen, A., Thompson, A., Robertson, S., & Van Loosdrecht, M. (2017). Aerobic granular biomass technology: Advancements in design, applications and further developments. Water Practice & Technology, 12(4), 987–996.
Randall, C. W., & Sen, D. (1996). Full-scale evaluation of an integrated fixed-film activated sludge (IFAS) process for enhanced nitrogen removal. Water Science and Technology, 33(12), 155–162.
Ren, X., Shon, H. K., Jang, N., Lee, Y. G., Bae, M., Lee, J., Cho, K., & Kim, I. S. (2010). Novel membrane bioreactor (MBR) coupled with a nonwoven fabric filter for household wastewater treatment. Water Research, 44(3), 751–760.
Rivas, A., Irizar, I., & Ayesa, E. (2008). Model-based optimisation of wastewater treatment plants design. Environmental Modelling & Software, 23(4), 435–450.
Rodrigues, A. C., Brito, A. G., & Melo, L. F. (2001). Posttreatment of a brewery wastewater using a sequencing batch reactor. Water Environment Research, 73(1), 45–51.
Sirianuntapiboon, S., Jeeyachok, N., & Larplai, R. (2005). Sequencing batch reactor biofilm system for treatment of milk industry wastewater. Journal of Environmental Management, 76(2), 177–183.
Sirianuntapiboon, S., & Yommee, S. (2006). Application of a new type of moving bio-film in aerobic sequencing batch reactor (aerobic-SBR). Journal of Environmental Management, 78(2), 149–156.
Soliman, M., & Eldyasti, A. (2018). Ammonia-oxidizing bacteria (AOB): Opportunities and applications—A review. Reviews in Environmental Science and Bio/technology, 17(2), 285–321.
States, U. N. D. P. R. B. for A., & utvecklingssamarbete, S. S. för internationellt (2013). Water governance in the Arab region: managing scarcity and securing the future. United Nations Publications.
Thirumurthi, D., & Orlando, J. R. (1976). Biochemical and physical-chemical treatment of weak municipal wastewater. Journal (Water Pollution Control Federation), 2708–2722.
Wang, Y.-K., Sheng, G.-P., Li, W.-W., & Yu, H.-Q. (2012). A pilot investigation into membrane bioreactor using mesh filter for treating low-strength municipal wastewater. Bioresource Technology, 122, 17–21.
We, A. C. E., Aris, A., & Zain, N. A. M. (2020). A review of the treatment of low–medium strength domestic wastewater using aerobic granulation technology. Environmental Science: Water Research & Technology, 6(3), 464–490.
Wei, D., Qiao, Z., Zhang, Y., Hao, L., Si, W., Du, B., & Wei, Q. (2013). Effect of COD/N ratio on cultivation of aerobic granular sludge in a pilot-scale sequencing batch reactor. Applied Microbiology and Biotechnology, 97(4), 1745–1753.
Wei, D., Wang, B., Ngo, H. H., Guo, W., Han, F., Wang, X., Du, B., & Wei, Q. (2015). Role of extracellular polymeric substances in biosorption of dye wastewater using aerobic granular sludge. Bioresource Technology, 185, 14–20.
Weijers, S. R., & Vanrolleghem, P. A. (1997). A procedure for selecting best identifiable parameters in calibrating activated sludge model no. 1 to full-scale plant data. Water Science and Technology, 36(5), 69–79.
Acknowledgements
The author is thankful to the authorities and management of Zenien wastewater treatment plant management team for providing wastewater analysis data of the plant.
Funding
Open access funding provided by The Science, Technology & Innovation Funding Authority (STDF) in cooperation with The Egyptian Knowledge Bank (EKB).
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Competing interests
The author declares no competing interests.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Latif, E.F. Applying novel methods in conventional activated sludge plants to treat low-strength wastewater. Environ Monit Assess 194, 323 (2022). https://doi.org/10.1007/s10661-022-09968-9
Received:
Accepted:
Published:
DOI: https://doi.org/10.1007/s10661-022-09968-9