Abstract
Objectives
To determine whether a combination of different types of elastography could improve the accuracy of elastography-aided downgrading ultrasound (US) Breast Imaging-Reporting and Data System (BI-RADS) category 4a lesions.
Materials and methods
From January 2016 to May 2018, 458 consecutive women with 494 US BI-RADS category 4a breast lesions were enrolled in the prospective study. These lesions were subject to conventional US supplemented with strain elastography of elasticity imaging (EI), virtual touch tissue imaging (VTI), and shear wave elastography of virtual touch imaging quantification (VTIQ). Diagnostic performances were calculated for BI-RADS, EI, VTI, and VTIQ as well as the combination of EI, VTI, and VTIQ (combination of EI and VTI [EI + VTI], combination of EI and VTIQ [EI + VTIQ], and combination of VTI and VTIQ [VTI + VTIQ]).
Results
Pathologically, 445 lesions (90.1%) were benign, and 49 (9.9%) were malignant. The specificities of EI, VTI, and VTIQ were significantly higher than those of BI-RADS (69.9%, 83.8%, 75.5% vs. 0, respectively, P < 0.001), while their sensitivities were significantly lower than those of BI-RADS (83.7%, 73.5%, 65.3% vs. 100%, respectively, P < 0.05). Among the combinations, EI + VTI and EI + VTIQ showed similar sensitivity to BI-RADS (98% vs 100%, P = 1.000; 93.9% vs 100%, P = 0.25), while the specificity of EI + VTI was significantly higher than that of EI + VTIQ and BI-RADS (P < 0.001). When using EI + VTI to downgrade lesions, 58.7% of these lesions were downgraded, among those 99.7% were benign.
Conclusions
Combinations of EI and VTI to downgrade BI-RADS category 4a lesions may reduce the misdiagnosis of breast cancers and the number of unnecessary biopsies.
Similar content being viewed by others
Abbreviations
- US:
-
Ultrasound
- BI-RADS:
-
Breast Imaging-Reporting and Data System
- EI:
-
Elastic imaging
- VTI:
-
Virtual touch tissue imaging
- VTIQ:
-
Virtual touch imaging quantification
- SWV:
-
Shear wave velocity
- AUC:
-
Area under the receiver operating characteristic curve
- EI + VTI:
-
Combination of EI and VTI
- EI + VTIQ:
-
Combination of EI and VTIQ
- VTI + VTIQ:
-
Combination of VTI and VTIQ
References
Siegel RL, Miller KD, Jemal A (2018) Cancer statistics, 2018. CA Cancer J Clin 68:7–30
Hille H, Jung I, Park J et al (2016) Is mammography superior to breast ultrasound? Some remarks to: Moon HJ. Ultraschall in Med 2015 36:255–263
Moon HJ, Jung I, Park SJ, Kim MJ, Youk JH, Kim EK (2015) Comparison of cancer yields and diagnostic performance of screening mammography vs. supplemental screening ultrasound in 4394 women with average risk for breast cancer. Ultraschall Med 36:255–263
Berg WA, Zhang Z, Lehrer D et al (2012) Detection of breast cancer with addition of annual screening ultrasound or a single screening MRI to mammography in women with elevated breast cancer risk. JAMA 307:1394–1404
Yi A, Cho N, Chang JM, Koo HR, La Yun B, Moon WK (2012) Sonoelastography for 1,786 non-palpable breast masses: diagnostic value in the decision to biopsy. Eur Radiol 22:1033–1040
Lee SH, Chang JM, Kim WH et al (2014) Added value of shear-wave elastography for evaluation of breast masses detected with screening US imaging. Radiology 273:61–69
Berg WA, Cosgrove DO, Dore CJ et al (2012) Shear-wave elastography improves the specificity of breast US: the BE1 multinational study of 939 masses. Radiology 262:435–449
Berg WA (2018) Can optoacoustic imaging safely reduce benign breast biopsies? Radiology 287:413–415
Itoh A, Ueno E, Tohno E et al (2006) Breast disease: clinical application of US elastography for diagnosis. Radiology 239:341–350
Garra BS, Cespedes EI, Ophir J et al (1997) Elastography of breast lesions: initial clinical results. Radiology 202:79–86
Plecha DM, Pham RM, Klein N, Coffey A, Sattar A, Marshall H (2014) Addition of shear-wave elastography during second-look MR imaging-directed breast US: effect on lesion detection and biopsy targeting. Radiology 272:657–664
Zhou J, Zhan W, Chang C et al (2014) Breast lesions: evaluation with shear wave elastography, with special emphasis on the “stiff rim” sign. Radiology 272:63–72
Lee SH, Cho N, Chang JM et al (2013) Two-view versus single-view shear-wave elastography: comparison of observer performance in differentiating benign from malignant breast masses. Radiology 270:344–353
Hooley RJ, Scoutt LM, Philpotts LE (2013) Breast ultrasonography: state of the art. Radiology 268:642–659
Cosgrove DO, Berg WA, Dore CJ et al (2012) Shear wave elastography for breast masses is highly reproducible. Eur Radiol 22:1023–1032
Xiao X, Jiang Q, Wu H, Guan X, Qin W, Luo B (2017) Diagnosis of sub-centimetre breast lesions: combining BI-RADS-US with strain elastography and contrast-enhanced ultrasound-a preliminary study in China. Eur Radiol 27:2443–2450
Ianculescu V, Ciolovan LM, Dunant A et al (2014) Added value of virtual touch IQ shear wave elastography in the ultrasound assessment of breast lesions. Eur J Radiol 83:773–777
Li XL, Xu HX, Bo XW et al (2016) Value of virtual touch tissue imaging quantification for evaluation of ultrasound Breast Imaging-Reporting and Data System Category 4 Lesions. Ultrasound Med Biol 42:2050–2057
Li DD, Xu HX, Guo LH et al (2016) Combination of two-dimensional shear wave elastography with ultrasound breast imaging reporting and data system in the diagnosis of breast lesions: a new method to increase the diagnostic performance. Eur Radiol 26:3290–3300
Lee SH, Chung J, Choi HY et al (2017) Evaluation of screening US-detected breast masses by combined use of elastography and color doppler US with B-Mode US in women with dense breasts: A multicenter prospective study. Radiology 285:660–669
Teke M, Goya C, Teke F et al (2015) Combination of virtual touch tissue imaging and virtual touch tissue quantification for differential diagnosis of breast lesions. J Ultrasound Med 34:1201–1208
Shikhman R, Keppke AL (2018) Breast, Imaging, Reporting and Data System (BI RADS)
Zhi H, Ou B, Xiao XY et al (2013) Ultrasound elastography of breast lesions in chinese women: a multicenter study in China. Clin Breast Cancer 13:392–400
Zhang YF, He Y, Xu HX et al (2014) Virtual touch tissue imaging on acoustic radiation force impulse elastography: a new technique for differential diagnosis between benign and malignant thyroid nodules. J Ultrasound Med 33:585–595
Yoon JH, Jung HK, Lee JT, Ko KH (2013) Shear-wave elastography in the diagnosis of solid breast masses: what leads to false-negative or false-positive results? Eur Radiol 23:2432–2440
Youk JH, Gweon HM, Son EJ, Han KH, Kim JA (2013) Diagnostic value of commercially available shear-wave elastography for breast cancers: integration into BI-RADS classification with subcategories of category 4. Eur Radiol 23:2695–2704
Barr RG, Nakashima K, Amy D et al (2015) WFUMB guidelines and recommendations for clinical use of ultrasound elastography: Part 2: breast. Ultrasound Med Biol 41:1148–1160
Shiina T, Nightingale KR, Palmeri ML et al (2015) WFUMB guidelines and recommendations for clinical use of ultrasound elastography: Part 1: basic principles and terminology. Ultrasound Med Biol 41:1126–1147
Lee JH, Kim SH, Kang BJ et al (2011) Role and clinical usefulness of elastography in small breast masses. Acad Radiol 18:74–80
Barr RG, Zhang Z, Cormack JB, Mendelson EB, Berg WA (2013) Probably benign lesions at screening breast US in a population with elevated risk: prevalence and rate of malignancy in the ACRIN 6666 trial. Radiology 269:701–712
Berg WA, Mendelson EB (2014) Technologist-performed handheld screening breast US imaging: how is it performed and what are the outcomes to date? Radiology 272:12–27
Chae EY, Cha JH, Shin HJ, Choi WJ, Kim HH (2016) Reassessment and follow-up results of BI-RADS category 3 lesions detected on screening breast ultrasound. AJR Am J Roentgenol 206:666–672
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Ethical approval
All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards. The experiments comply with the current laws of China.
Informed consent
Verbal informed consent was obtained from all individual participants included in the study.
Rights and permissions
About this article
Cite this article
Zheng, X., Huang, Y., Wang, Y. et al. Combination of different types of elastography in downgrading ultrasound Breast Imaging-Reporting and Data System category 4a breast lesions. Breast Cancer Res Treat 174, 423–432 (2019). https://doi.org/10.1007/s10549-018-05072-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10549-018-05072-0