Skip to main content
Log in

Clinical performance of a low cost near infrared sensor for continuous glucose monitoring applied with subcutaneous microdialysis

  • Published:
Biomedical Microdevices Aims and scope Submit manuscript

Abstract

In this work we present a low cost, minimally invasive, and chip-based near infrared (NIR) sensor, combined with subcutaneous microdialysis, for continuous glucose monitoring (CGM). The sensor principle is based on difference absorption spectroscopy in the 1st overtone band known to be dominated by glucose-specific absorption features. The device comprises a multi-emitter LED and InGaAs-photodiodes, which are located on a single electronic board (non-disposable part), connected to a personal computer via Bluetooth. The disposable part consists of a chip containing the fluidic connections for microdialysis, two fluidic channels acting as optical transmission cells and total internally reflecting mirrors for in- and out-coupling of the light to the chip and to the detectors. The use of the sensor in conjunction with a subcutaneous microdialysis catheter to separate the glucose from the cells and proteins has been demonstrated to be extremely useful and advantageous for obtaining continuous glucose monitoring data and detecting glycemic levels in real time for a long period. Several in vitro and in vivo experiments were conducted to test the reliability of the device. In vitro measurements showed a linear relationship between glucose concentration and the integrated difference signal with a coefficient of determination of 99 % at the physiological concentration range. Clinical trial on 6 subjects with Type 1 diabetes showed that the NIR-CGM sensor data reflects the blood reference values adequately, if a proper calibration and signal drift compensation is applied. The MARD (mean absolute relative difference) value taken on retrospective data over all subjects is 8.5 % (range 6–11.5 %).

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9

Similar content being viewed by others

References

  • K. Amerov, J. Chen, M.A. Arnold, Appl. Spectrosc. 58, 1195–1204 (2004)

    Article  Google Scholar 

  • T. Bailey, H. Zisser, A. Chang, Diabetes Technol. Ther. 11(12), 749–755 (2009)

    Article  Google Scholar 

  • L. Ben Mohammadi, S. Sigloch, I. Frese, V. Stein, K. Welzel, F. Schmitz, T. Klotzbücher, Proc. SPIE 8427, Biophotonics: Photonic Solutions for Better Health Care III, 84270K (2012). doi:10.1117/12.922381

  • L. Ben Mohammadi, T. Klotzbücher, S. Sigloch, K. Welzel, M. Göddel, T.R. Pieber, L. Schaupp, Biosens. Bioelectron. 53, 99–104 (2014). doi:10.1016/j.bios.2013.09.043

    Article  Google Scholar 

  • L. Benmohammadi, S. Sigloch, I. Frese, K. Welzel, M. Göddel, T. Klotzbücher, Proc. SPIE 9129, Biophotonics: Photonic Solutions for Better Health Care IV, 912929 (2014). doi: 10.1117/12.2052216

  • J. Bolinder, E. Hangstrom, U. Ungerstedt, P. Arner, Scand. J. Clin. Lab. Invest. 49, 465–474 (1989)

    Article  Google Scholar 

  • J. Bolinder, U. Ungerstedtm, P. Arner, Diabetologia 35, 1177–1180 (1992)

    Article  Google Scholar 

  • J. Brauker, Diabetes Technol. Ther. 11(Suppl 1), S25–S36 (2009). doi:10.1089/dia.2008.0137

    Google Scholar 

  • P.M. Bungay, P.F. Morrison, R.L. Dedrick, Life Sci. 46, 105–119 (1990)

    Article  Google Scholar 

  • W.L. Clarke, D. Cox, L.A. Gonder-Frederick, W. Carter, S.L. Pohl, Diabetes Care 10, 622–628 (1987)

    Article  Google Scholar 

  • K.H. Hazen, M.A. Arnold, G.W. Small, Appl. Spectrosc. 52(12), 1597–1605 (1998a)

    Article  Google Scholar 

  • K.H. Hazen, M.A. Arnold, G.W. Small, Anal. Chim. Acta 371(1–2), 255–267 (1998b)

    Article  Google Scholar 

  • International Diabetes Federation, IDF Diabetes Atlas, 6th edn. (International Diabetes Federation, Brussels, 2013). http://www.idf.org/diabetesatlas . Accessed 30 November 2014

  • JDRF CGM Study Group, Diabetes Technol. Ther. 10, 310–321 (2008)

    Article  Google Scholar 

  • JDRF CGM Study Group, Diabetes Care 32(11), 1947–1953 (2009). doi:10.2337/dc09-0889

    Article  Google Scholar 

  • J. Kehr, J. Neurosci. Methods 48, 251–261 (1993)

    Article  Google Scholar 

  • M. Langendam, YM. Luijf, L. Hooft, JH. DeVries, AH Mudde, R. JPM Scholten, Cochrane Database Syst. Rev. Issue 1. Art. No.: CD008101 (2012). doi: 10.1002/14651858.CD008101.pub2

  • M.K.K. Lee, L. Di, Pharm. Anal. Acta 5, 276 (2014). doi:10.4172/2153-2435.1000276

    Google Scholar 

  • J.T. Olesberg, C. Cao, J.R. Yager, J.P. Prineas, C. Coretsopoulos, M.A. Arnold, L.J. Olafsen, M. Santilli, Proc. SPIE 6094, 16–25 (2006)

    Google Scholar 

  • J.C. Pickup, S.C. Freeman, A.J. Sutton, BMJ 343, d3805 (2011). doi:10.1136/bmj.d3805

    Article  Google Scholar 

  • L. Schaupp, M. Ellmerer, G.A. Brunner, A. Wutte, G. Sendlhofer, Z. Trajanoski, F. Skrabal, T.R. Pieber, P. Wach, Am. J. Physiol. 276(2), E401–E408 (1999)

    Google Scholar 

  • J. A. Stenken, in In Vivo Glucose Sensing, ed. by D. D. Cunningham and J. A. Stenken (Wiley, 2009), pp. 157–190

  • A. Trabelsi, M. Boukadoum, M. Siaj, Am. J. Biomed. Eng. 1(2), 62–67 (2011). doi:10.5923/j.ajbe.20110102.11

    Article  Google Scholar 

  • U. Ungerstedt, J. Intern. Med. 230, 365–373 (1991)

    Article  Google Scholar 

  • H.C. Zisser, T.S. Bailey, S. Schwartz, R.E. Ratner, J. Wise, J Diabetes Sci. Technol. 3(5), 1146–1154 (2009)

    Article  Google Scholar 

Download references

Acknowledgments

Financial support by the European Union in the seventh framework program (Grant agreement No.: FP7 248590) is gratefully acknowledged. The staff of the Clinical Research Center at Medical University of Graz is thankfully acknowledged for support in performing the clinical studies. We are indebted to the dedicated subjects who participated in this research project.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Lhoucine Ben Mohammadi.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ben Mohammadi, L., Klotzbuecher, T., Sigloch, S. et al. Clinical performance of a low cost near infrared sensor for continuous glucose monitoring applied with subcutaneous microdialysis. Biomed Microdevices 17, 73 (2015). https://doi.org/10.1007/s10544-015-9983-4

Download citation

  • Published:

  • DOI: https://doi.org/10.1007/s10544-015-9983-4

Keywords

Navigation