Abstract
Between August 2016 and January 2017 nine shallow earthquakes ranging from 5.0 and 6.5 of moment magnitude affected Central Italy, involving several municipalities wherein unreinforced masonry buildings are more than three quarters of all constructions. Damage state has been very severe, with sixteen settlements belonging to the municipalities of Amatrice, Arquata del Tronto, Accumoli, Castelsantangelo sul Nera and Norcia experiencing a cumulative European macroseismic scale intensity larger than IX. Ground motion demand in terms of peak ground velocity was approximately two or three times what expected for a 475 years return period while the pseudoacceleration response spectra showed values between once and twice gravity acceleration for the period range typical of two and three storeys unreinforced masonry buildings. Moreover, since October 2016, such large seismic demand acted on structures damaged from previous shocks testifying the effects of damage accumulation, too. The significant shaking alone cannot explain the extremely severe damage of some settlements, with large portions of whole blocks completely collapsed, highlighting the need for investigating the specific vulnerability factors and construction features of unreinforced masonry buildings in the affected area. In fact, although some deficiencies already highlighted in previous Italian earthquakes (e.g. inadequate structural connections) have been surveyed also during this sequence, a marked vulnerability of masonry and its mortar has been noticed, in particular in the area between Amatrice and Arquata del Tronto. On the contrary, the historical constructions in Norcia performed much better, as a result of the 1860 seismic code and of the retrofitting interventions implemented after the different earthquakes occurred in the last two centuries. Finally, a number of demolished and rebuilt constructions performed very well, and this was also the case also of modern hollow clay blockwork buildings that protected not only human life, but also cost of construction and continuity of use.
Similar content being viewed by others
References
Allen TI, Wald DJ (2009) On the use of high-resolution topographic data as a proxy for seismic site conditions (VS30). Bull Seismol Soc Am 99:935–943. https://doi.org/10.1785/0120080255
Artioli G, Secco M, Mazzoli C et al (2010) Characterization of stone masonry panels consolidated by injection of grouts in buildings damaged by the 2009 Abruzzo earthquake. In: Valek J, Groot C, Hughes J (eds) 2nd historic mortars conference and RILEM TC 203-RHM “repair mortars for historic masonry” final workshop, Prague, Czech Republic, 22–24 September 2010. RILEM Publications, Bagneux, pp 871–881
Artioli G, Casarin F, Dalla Benetta M et al (2011) Restoration of historic masonry structures damaged by the 2009 Abruzzo earthquake through injection grouts. In: Ingham J, Dhanasekar M, Masia M (eds) 9th Australasian masonry conference. Queenstown, New Zealand, 15–18 February 2011
Augenti N, Parisi F (2010) Learning from construction failures due to the 2009 L’Aquila, Italy, earthquake. J Perform Constr Facil 24:536–555. https://doi.org/10.1061/(ASCE)CF.1943-5509.0000122
Azzaro R, Barbano MS, D’Amico S et al (2011) The L’Aquila 2009 earthquake: an application of the European Macroseismic Scale to the damage survey in the epicentral area. Boll di Geofis Teor ed Appl 52:561–581. https://doi.org/10.4430/bgta0012
Azzaro R, Tertulliani A, Bernardini F et al (2016) The 24 August 2016 Amatrice earthquake: macroseismic survey in the damage area and EMS intensity assessment. Ann Geophys 59:1–10. https://doi.org/10.4401/ag-7203
Binda L, Cardani G, Saisi A (2005) Application of a multidisciplinary investigation to study the vulnerability of Castelluccio (Umbria). Struct Stud repairs Maint Herit Archit IX 83:311–322
Booth E (2007) The estimation of peak ground-motion parameters from spectral ordinates. J Earthq Eng. https://doi.org/10.1080/13632460601123156
Boschi E, Guidoboni E, Ferrari G, Valensise G (1998) I terremoti dell’Appenino Umbro – Marchigiano. Compositori, Bologna
Camassi R, Azzaro R, Tertulliani A (2008) Macroseismology: The lessons learnt from the 1997/1998 colfiorito siesmic sequence
Cattari S, degli Abbati s, Ferretti D et al (2012) The seismic behaviour of ancient masonry buildings after the earthquake in Emilia (Italy) on May 20th and 29th. Ing Sismica—Int J Earthq Eng 23:87–111
D’Ayala DF, Paganoni S (2011) Assessment and analysis of damage in L’Aquila historic city centre after 6th April 2009. Bull Earthq Eng 9:81–104. https://doi.org/10.1007/s10518-010-9224-4
Decanini L, De Sortis A, Goretti A et al (2004) Performance of masonry buildings during the 2002 Molise, Italy, earthquake. Earthq Spectra 20:S191–S220. https://doi.org/10.1193/1.1765106
DM (1983) Decreto Ministeriale 10 febbraio 1983. Aggiornamento delle zone sismiche della regione Marche. Gazzetta Ufficiale 23 marzo 1983, n.80
DMI (2008) Decreto del Ministro delle Infrastrutture 14 gennaio 2008. Approvazione delle nuove norme tecniche per le costruzioni. Gazzetta Ufficiale della Repubblica Italiana, n. 29 del 4 febbraio 2008, Supplemento Ordinario n. 30
DMLP (1987) Decreto del Ministro dei Lavori Pubblici. Norme tecniche per la progettazione, esecuzione e collaudo degli edifici in muratura e per il loro consolidamento. Gazzetta Ufficiale della Repubblica Italiana 5 dicembre 1987 n.285
DMLP (1996) Decreto del Ministro dei Lavori Pubblici del 16 gennaio 1996. Norme Tecniche per le Costruzioni in Zone Sismiche. Gazzetta Ufficiale della Repubblica Italiana, 5 febbraio 1996, n. 19
EC8-1 (2004) Eurocode 8: design of structures for earthquake resistance—Part 1: general rules, seismic actions and rules for buildings. European Committee for Standardization, Brussels
Favali P, Giovani I, Spadea MC, Vecchi M (1980) Il terremoto della Valnerina del 19 settembre 1979. Ann di Geofis 33:67–100
Fumagalli F, Liberatore D, Monti G, Sorrentino L (2017) Building features of Accumoli and Amatrice in a pre-earthquake survey. In: Proceedings of the 17th Italian national conference on earthquake engineering, Pistoia, 17–21 September, pp SG03.45–SG03.54
Galli P, Molin D (2004) Macroseismic survey of the 2002 Molise, Italy, earthquake and historical seismicity of San Giuliano di Puglia. Earthq. Spectra 20:S39–S52
Giaretton M, Valluzzi M, Mazzon N, Modena C (2017) Out-of-plane shake-table test of strengthened multi-leaf stone masonry walls. Bull Earthq Eng. https://doi.org/10.1007/s10518-017-0125-7
Grünthal G (1998) Cahiers du Centre Européen de Géodynamique et de Séismologie: Volume 15—European Macroseismic Scale 1998. European Center for Geodynamics and Seismology, Luxembourg
ISTAT (2001) Istituto Nazionale di Statistica. 14° Censimento generale della popolazione e delle abitazioni. http://gisportal.istat.it/bt.viewer/
ISTAT (2011) Istituto Nazionale di Statistica. 15° Censimento generale della popolazione e delle abitazioni. http://dati-censimentopopolazione.istat.it/
L (1962) Legge 1684. Provvedimenti per l’edilizia con particolari prescrizioni per le zone sismiche. Gazzetta Ufficiale della Repubblica Italiana, 22 dicembre 1962, No. 326
Liberatore D, Masini N, Sorrentino L et al (2016) Static penetration test for historical masonry mortar. Constr Build Mater 122:810–822. https://doi.org/10.1016/j.conbuildmat.2016.07.097
Locati M, Camassi R, Rovida A et al (2016) DBMI15, the 2015 version of the Italian Macroseismic database
Magenes G, Penna A, Senaldi I et al (2014) Shaking table test of a strengthened full-scale stone masonry building with flexible diaphragms. Int J Archit Herit 8:349–375. https://doi.org/10.1080/15583058.2013.826299
Margottini C, Molin D, Narcisi B, Serva L (1987) Intensity vs. acceleration: Italian data. In: Margottini C, Serva L (ed) Proceedings of the workshop on historical seismicity of the central-eastern mediterranean region. ENEA-IAEA, Rome
Mollaioli F, AlShawa O, Liberatore L et al (2018) Seismic demand of the 2016–2017 Central Italy Earthquakes. Bull Earthq Eng (submitted for this issue)
Mosele F (2017) Central Italy earthquakes 2016: reconnaissance of modern clay masonry buildings and considerations about the seismic classification of buildings. In: Proceedings of the 17th Italian national conference on earthquake engineering, Pistoia, 17–21 September, pp SS02.14–SS02.21 (in Italian)
Mouyiannou A, Penna A, Rota M et al (2014) Implications of cumulated seismic damage on the seismic performance of unreinforced masonry buildings. Bull New Zeal Soc Earthq Eng 47:157–170
Penazzi D, Valluzzi MR, Cardani G et al (2000) Behaviour of historic masonry buildings in seismic areas: lessons learned from the Umbria-Marche earthquake. In: 12th International brick/block masonry conference, Madrid, Spain, pp 217–235
Penna A, Morandi P, Rota M et al (2014) Performance of masonry buildings during the Emilia 2012 earthquake. Bull Earthq Eng 12:2255–2273. https://doi.org/10.1007/s10518-013-9496-6
Perrone D, Calvi P, Nascimbene R et al (2018) Seismic performance of non-structural elements during the 2016 Central Italy Earthquake. Bull Earthq Eng. https://doi.org/10.1007/s10518-018-0361-5
RDL (1915) Regio Decreto Legge 29 aprile 1915 n. 573, che riguarda le norme tecniche ed igieniche da osservarsi per i lavori edilizi nelle località colpite dal terremoto del 13 gennaio 1915. Gazzetta Ufficiale n.117, 11 maggio 1915
RDL (1927) Regio Decreto Legge 13 marzo 1927 n. 431, norme tecniche ed igieniche di edilizia per le località colpite dai terremoti. Gazzetta Ufficiale n.82, 8 aprile 1927
Reale C, Scheibel B, Vignoli F et al (2004) Il Regolamento edilizio di Norcia del 1860: fra storia sismica e storia urbanistica. In: Proceedings of the 11th Italian national earthquake engineering conference, Genoa, 25–29 January, paper C1–08
Rota M, Penna A, Strobbia CL (2008) Processing Italian damage data to derive typological fragility curves. Soil Dyn Earthq Eng 28:933–947. https://doi.org/10.1016/j.soildyn.2007.10.010
Rovida A, Locati M, Camassi R et al (2016) CPTI15, the 2015 version of the parametric catalogue of Italian earthquakes. http://emidius.mi.ingv.it/CPTI15-DBMI15/query_eq/
Secchi A (1860) Escursione scientifica fatta a Norcia ad occasione dei terremoti del 22 agosto 1859. Atti dell’Accademia Pontif de’ nuovi Lincei 13:63–104
Senaldi I, Magenes G, Penna A et al (2014) The effect of stiffened floor and roof diaphragms on the experimental seismic response of a full-scale unreinforced stone masonry building. J Earthq Eng 18:407–443. https://doi.org/10.1080/13632469.2013.876946
Sieberg A (1930) Geologie der Erdbeben. In: Gutenberg B (ed) Handbuch der Geophysik. Gebruder Borntraeger, Berlin, pp 526–686
Silva B, Dalla Benetta M, Da Porto F, Modena C (2014) Experimental assessment of in-plane behaviour of three-leaf stone masonry walls. Constr Build Mater 53:149–161. https://doi.org/10.1016/j.conbuildmat.2013.11.084
Sisti R, Di Ludovico M, Borri A, Prota A (2018) Damage assessment and the effectiveness of prevention: the response in buildings in Norcia. Bull Earthq Eng (submitted for this issue)
Sorrentino L (2007) The early entrance of dynamics in earthquake engineering: Arturo Danusso’s contribution. ISET J Earthq Technol 44:1–24
Sorrentino L, Tocci C (2008) The structural strengthening of early and mid 20th century reinforced concrete diaphragms. In: Sixth international conference on structural analysis of historic construction, 2–4 July, Bath, pp 1431–1439
Sorrentino L, Bruccoleri D, Antonini M (2008) Structural interpretation of post-earthquake (19th century) retrofitting on the Santa Maria degli Angeli Basilica, Assisi, Italy. In: Sixth international conference on structural analysis of historic construction, 2–4 July, Bath, pp 217–225
Sorrentino L, Liberatore L, Decanini LD, Liberatore D (2014) The performance of churches in the 2012 Emilia earthquakes. Bull Earthq Eng 12:2299–2331. https://doi.org/10.1007/s10518-013-9519-3
Sorrentino L, D’Ayala D, de Felice G et al (2017) Review of out-of-plane seismic assessment techniques applied to existing masonry buildings. Int J Archit Herit 11:2–21. https://doi.org/10.1080/15583058.2016.1237586
Spence R, D’Ayala D (1999) Damage assessment and analysis of the 1997 Umbria-Marche earthquakes. Struct Eng Int J Int Assoc Bridg Struct Eng 9:229–233
Tertulliani A, Azzaro R (2016) QUEST–Rilievo macrosismico per i terremoti nell’Italia centrale. Aggiornamento dopo le scosse del 26 e 30 ottobre 2016. Roma
Tertulliani A, Arcoraci L, Berardi M et al (2012) The Emilia 2012 sequence: a macroseismic survey. Ann Geophys 55:679–687. https://doi.org/10.4401/ag-6140
Zucconi M, Sorrentino L, Ferlito R (2017) Principal component analysis for a seismic usability model of unreinforced masonry buildings. Soil Dyn Earthq Eng 96:64–75. https://doi.org/10.1016/j.soildyn.2017.02.014
Acknowledgements
This work has been partially carried out under the programs “Dipartimento della Protezione Civile—Consorzio RELUIS”, signed on the 24th February 2017, Research Line Masonry Structures. The opinions expressed in this publication are those of the authors and are not necessarily endorsed by the Dipartimento della Protezione Civile.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Sorrentino, L., Cattari, S., da Porto, F. et al. Seismic behaviour of ordinary masonry buildings during the 2016 central Italy earthquakes. Bull Earthquake Eng 17, 5583–5607 (2019). https://doi.org/10.1007/s10518-018-0370-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10518-018-0370-4