Skip to main content
Log in

Synchronization and Alignment of Follow-up Examinations: a Practical and Educational Approach Using the DICOM Reference Coordinate System

  • Published:
Journal of Digital Imaging Aims and scope Submit manuscript

Abstract

This work presents an approach for synchronization and alignment of Digital Imaging and Communications in Medicine (DICOM) series from different studies that allows, e.g., easier reading of follow-up examinations. The proposed concept developed within the DICOM’s patient-based reference coordinate system allows to synchronize all image data of two different studies/examinations based on a single registration. The most suitable DICOM series for registration could be set as default per protocol. Necessary basics regarding the DICOM standard and the used mathematical transformations are presented in an educative way to allow straightforward implementation in Picture Archiving And Communications Systems (PACS) and other DICOM tools. The proposed method for alignment of DICOM images is potentially also useful for various scientific tasks and machine-learning applications.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

Similar content being viewed by others

References

  1. Haak D, Page C-E, Deserno TM: A survey of DICOM viewer software to integrate clinical research and medical imaging. J Digit Imaging 29.2: 206–215, 2016

  2. Grood ES, Suntay WJ: A joint coordinate system for the clinical description of Three-Dimensional motions: Application to the knee. ASME. J Biomech Eng 105 (2): 136–144, 1983. https://doi.org/10.1115/1.3138397

  3. NEMA PS3 / ISO 12052, Digital Imaging and Communications in Medicine (DICOM) Standard, National Electrical Manufacturers Association, Rosslyn, VA, USA (available free at http://medical.nema.org/), 2018

  4. National Electrical Manufacturers Association: Digital Imaging and Communications in Medicine (DICOM) Part 3: Information Object Definitions: 7.6.2 Image Plane Module, 2011, pp 408– 410

  5. National Electrical Manufacturers Association:Digital Imaging and Communications in Medicine (DICOM) Part 3: Information Object Definitions : 3.17.1 Reference Coordinate System, 2011, p 55

  6. Xiangrui L, Morgan PS, Ashburner J, Smith J, Rorden C: The first step for neuroimaging data analysis: DICOM to NIfTI conversion. J Neurosci Methods 264: 47–56, 2016

  7. Gan J, Oyama E, Rosales E, Hu H: A complete analytical solution to the inverse kinematics of the Pioneer 2 robotic arm. Robotica 23: 123–129, 2005. https://doi.org/10.1017/S0263574704000529

  8. Ostuni JL, Santha AK, Mattay VS, Weinberger DR, Levin RL, Frank JA: Analysis of interpolation effects in the reslicing of functional MR images. J Comput Assist Tomogr 21 (5): 803–810, 1997

  9. Medical image registration. In: (Hajnal J, Hill DLG, Hawkes DJ, Eds.) Boca Raton: CRC Press, 2001

  10. Pluim JPW, Antoine Maintz JB, Viergever MA Mutual-information-based registration of medical images: a survey. IEEE transactions on medical imaging, 2003, pp 986–1004

  11. Malinsky M, Peter R, Hodneland E, Lundervold J., Lundervold A, Jan J: Registration of FA and T1-Weighted MRI data of healthy human brain based on template matching and normalized Cross-Correlation. J Digit Imaging 26: 774–785, 2013

  12. Jenkinson M, Bannister P, Brady M, Smith S: Improved optimization for the robust and accurate linear registration and motion correction of brain images. NeuroImage 17: 825–841, 2002. https://doi.org/10.1006/nimg.2002.1132

  13. Hoseini F, Shahbahrami A, Bayat P An efficient implementation of deep convolutional neural networks for MRI segmentation j digit imaging, 2018. https://doi.org/10.1007/S10278-018-0062-2

  14. Menze Bjoern H, et al. The multimodal brain tumor image segmentation benchmark (BRATS). IEEE transactions on medical imaging 34.10, 2015, pp 1993–2024

  15. Glocker B, Sotiras A, Komodakis N, Paragios N: Deformable medical image registration: setting the state of the art with discrete methods. Annu Rev Biomed Eng 13: 219–244, 2011

  16. Schnabel JA, Rueckert D, Quist M, Blackall JM, Castellano-Smith AD, Hartkens T, Gerritsen FA: A generic framework for non-rigid registration based on non-uniform multi-level free-form deformations.. In: International Conference on Medical Image Computing and Computer-Assisted Intervention. Springer, Berlin, 2001, pp 573–581

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Alois M Sprinkart.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Nowak, S., Sprinkart, A.M. Synchronization and Alignment of Follow-up Examinations: a Practical and Educational Approach Using the DICOM Reference Coordinate System. J Digit Imaging 32, 68–74 (2019). https://doi.org/10.1007/s10278-018-0117-4

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10278-018-0117-4

Keywords

Navigation