Background

There has been no absolute consensus on the optimal implant for fixation of medial clavicle fracture. The purpose of the present study was to test the biomechanical efficacy of inverted lateral clavicle locking compression plate (LCP-LC) in fixation of this specific fracture location by finite element analysis.

Methods

Transverse and comminuted medial clavicle fracture simulated models stabilized by three different devices including inverted LCP-LC, superior clavicle LCP (LCP-SC), and dual reconstruction (LCP-RP) with LCP-SC were investigated biomechanical performance under three loading conditions, i.e., axial compression, inferior bending, and axial torsion.

Results

EQV stress exhibited on implant and elastic strain at fracture site under inferior bending was greater than other loading cases. LCP-SC construct represented the greatest EQV stress and elastic strain. The inverted LCP-LC construct demonstrated lower EQV stress than the LCP-SC construct and was comparable to dual plating. Under axial compression and axial torsion, elastic strain produced from the inverted LCP-LC construct was comparable to dual plating, but greater than dual plating when subjected to inferior bending.

Conclusion

By the results of FE analysis, inverted LCP-LC could be a potential application for fixation of clavicle fracture with short medial fragment.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11

Similar content being viewed by others

Data availability

The datasets generated during the current study are available from the corresponding author on reasonable request.

References

  1. Robinson CM (1998) Fractures of the clavicle in the adult epidemiology and classification. J Bone Joint Surg Br 80(3):476–484

    Article  CAS  PubMed  Google Scholar 

  2. Robinson CM, Court-Brown CM, McQueen MM, Wakefield AE (2004) Estimating the risk of nonunion following nonoperative treatment of a clavicular fracture. J Bone Joint Surg Am 86(7):1359–1365

    Article  PubMed  Google Scholar 

  3. Postacchini F, Gumina S, De Santis P, Albo F (2002) Epidemiology of clavicle fractures. J Shoulder Elbow Surg 11(5):452–456

    Article  PubMed  Google Scholar 

  4. Bakir MS, Unterkofler J, Haralambiev L, Kim S, Carbon R, Ekkernkamp A (2021) Medial injuries of the clavicle: more prevalent than expected? A big data analysis of incidence, age, and gender distribution based on nationwide routine data. Eur J Trauma Emerg Surg 47(4):1175–1182

    Article  PubMed  Google Scholar 

  5. Frima H, van Heijl M, Michelitsch C, van der Meijden BFJP, Houwert RM et al (2020) Clavicle fractures in adults; current concepts. Eur J Trauma Emerg Surg 46(3):519–529

    Article  PubMed  Google Scholar 

  6. Oe K, Gaul L, Hierholzer C, Woltmann A, Miwa M, Kurosaka M et al (2012) Operative management of periarticular medial clavicle fractures-report of 10 cases. J Trauma 72(2):E1–E7

    Google Scholar 

  7. Wang Y, Jiang J, Dou B, Zhang P (2015) Inverted distal clavicle anatomic locking plate for displaced medial clavicle fracture. Arch Orthop Trauma Surg 135(9):1241–1245

    Article  PubMed  Google Scholar 

  8. Vannabouathong C, Chiu C, Patel R, Sreeraman S, Mohamed E, Bhandari M et al (2020) An evaluation of treatment options for medial, midshaft, and distal clavicle fractures: a systematic review and meta-analysis. JSES Int 4(2):256–271

    Article  PubMed  PubMed Central  Google Scholar 

  9. Kim KC, Shin HD, Cha SM (2011) Surgical treatment of displaced medial clavicle fractures using a small T-shaped plate and tension band sutures. Arch Orthop Trauma Surg 131(12):1673–1676

    Article  PubMed  Google Scholar 

  10. Zúñiga DG, García LF, Leal JA (2021) Biplanar osteosynthesis for severely displaced proximal- third clavicle fracture: a case report. JBJS Case Connect 11(2):e2000584

    Article  Google Scholar 

  11. Liu Z, Zhang J, Tian X, Kan S (2019) Displaced medial-end clavicle fractures treated with locking plate osteosynthesis. Med Sci Monit 9(25):7591–7596

    Article  Google Scholar 

  12. Wurm M, Siebenlist S, Zyskowski M, Pflüger P, Biberthaler P, Beirer M et al (2021) Excellent clinical and radiological outcome following locking compression plate fixation of displaced medial clavicle fractures. BMC Musculoskelet Disord 22(1):905

    Article  PubMed  PubMed Central  Google Scholar 

  13. Frima H, Houwert RM, Sommer C (2020) Displaced medial clavicle fractures: operative treatment with locking compression plate fixation. Eur J Trauma Emerg Surg 46(1):207–213

    Article  PubMed  Google Scholar 

  14. Fedorov A, Beichel R, Kalpathy-Cramer J, Finet J, Fillion-Robin J-C, Pujol S et al (2012) 3D slicer as an image computing platform for the quantitative imaging network. Magn Reson Imaging 30(9):1323–1341

    Article  PubMed  PubMed Central  Google Scholar 

  15. Fontana AD, Hoyen HA, Blauth M, Galm A, Schweizer M, Raas C et al (2020) The variance of clavicular surface morphology is predictable: an analysis of dependent and independent metadata variables. JSES Int 4(3):413–421

    Article  PubMed  PubMed Central  Google Scholar 

  16. Wu DK, Chen WC, Lin KJ, Tsai CL, Lin KP, Wei HW (2021) Advantage of multi-directional stability of spiral clavicle plate in treatment of middle one-third clavicle fracture: a finite element study. J Med Biol Eng 41(4):405–411

    Article  Google Scholar 

  17. Chantarapanich N, Sitthiseripratip K, Mahaisavariya B, Siribodhi P (2016) Biomechanical performance of retrograde nail for supracondylar fractures stabilization. Med Biol Eng Comput 54(6):939–952

    Article  PubMed  Google Scholar 

  18. Zhang F, Chen F, Qi Y, Qian Z, Ni S, Zhong Z et al (2020) Finite element analysis of dual small plate fixation and single plate fixation for treatment of midshaft clavicle fractures. J Orthop Surg Res 15(1):148

    Article  PubMed  PubMed Central  Google Scholar 

  19. Pengrung N, Lakdee N, Puncreobutr C, Lohwongwatana B, Sa-Ngasoongsong P (2019) Finite element analysis comparison between superior clavicle locking plate with and without screw holes above fracture zone in midshaft clavicular fracture. BMC Musculoskelet Disord 20(1):465

    Article  PubMed  PubMed Central  Google Scholar 

  20. Shih KS, Hsu CC, Shih BY (2020) A biomechanical study of various fixation strategies for the treatment of clavicle fractures using three-dimensional upper-body musculoskeletal finite element models. Appl Sci 10(16):5651

    Article  CAS  Google Scholar 

  21. Sasaki Y, Lee SY, Iwakura T, Tomoaki F, Keisuke O, Tomoyuki M (2019) Medial clavicle pseudarthrosis successfully treated with an inverted distal clavicle locking plate. Ann Med Surg (Lond) 6(44):1–4

    Google Scholar 

  22. Asadollahi S, Bucknill A (2019) Acute medial clavicle fracture in adults: a systematic review of demographics, clinical features and treatment outcomes in 220 patients. J Orthop Traumatol 20(1):24

    Article  PubMed  PubMed Central  Google Scholar 

  23. Throckmorton T, Kuhn JE (2017) Fractures of the medial end of the clavicle. J Shoulder Elbow Surg 16(1):49–54

    Article  Google Scholar 

  24. Bartoníček J, Frič V, Pacovský V (2010) Displaced fractures of the medial end of the clavicle: report of five cases. J Orthop Trauma 24(4):e31–e35

    Article  PubMed  Google Scholar 

  25. Fransen P, Bourgeois S, Rommens J (2007) Kirschner wire migration causing spinal cord injury one year after internal fixation of a clavicle fracture. Acta Orthop Belg 73(3):390–392

    PubMed  Google Scholar 

  26. Feng WL, Cai X, Li SH, Li ZJ, Zhang K, Wang H et al (2020) Balser plate stabilization for traumatic sternoclavicular instabilities or medial clavicle fractures: a case series and literature review. Orthop Surg 12(6):1627–1634

    Article  PubMed  PubMed Central  Google Scholar 

  27. Sinha A, EdwinSreeharsha JB, Bhalaik V, Brownson P (2011) A radiological study to define safe zones for drilling during plating of clavicle fractures. J Bone Joint Surg Br 93(9):1247–1252

    Article  CAS  PubMed  Google Scholar 

  28. Titchener A, See A, Van Rensburg L, Tytherleigh-Strong G (2019) Displaced medial end clavicular fractures treated with an inverted distal clavicle plate contoured through 90 degrees. J Shoulder Elbow Surg 28(4):e97–e103

    Article  PubMed  Google Scholar 

  29. Meeuwis MA, Pull Ter Gunne AF, Verhofstad MH, van der Heijden FH (2017) Construct failure after open reduction and plate fixation of displaced midshaft clavicular fractures. Injury 48(3):715–719

    Article  CAS  PubMed  Google Scholar 

Download references

Funding

There was no source of funding for this research.

Author information

Authors and Affiliations

Authors

Contributions

AK, SJ, and NC were involved in drafting and revising the manuscript for content, including the medical writing for the content, the study concept and design, the analysis and interpretation of the data, as well as the acquisition of the data. KA, AG, CP, and PD were involved in revising the manuscript for content as well as the analysis and interpretation of the data.

Corresponding author

Correspondence to Nattapon Chantarapanich.

Ethics declarations

Conflicts of interest

A. Kritsaneephaiboon, S. Jitprapaikulsarn, *N. Chantarapanich, P. Klabklay, A. Gromprasit, C. Patamamongkonchai, and P. Dissaneewate declare that they have no conflict of interest.

Ethical approval

This study has been approved by the ethical committees of Buddhachinaraj Hospital in accordance with the Declaration of Helsinki.

Consent to participate

Informed consent was obtained from all individual participants included in the study.

Consent to publish

The authors affirm that human research participants provided informed consent for publication of the images in all figures.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kritsaneephaiboon, A., Jitprapaikulsarn, S., Chantarapanich, N. et al. The application of inverted lateral clavicle locking compression plate for medial clavicle fractures: biomechanical study and clinical implementation. Eur J Orthop Surg Traumatol 34, 1465–1478 (2024). https://doi.org/10.1007/s00590-023-03826-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00590-023-03826-1

Keywords

Navigation