Abstract
A novel MEMS-based cantilever sensor with slender geometry is designed and fabricated to be implemented for determining personal exposure to carbon engineered nanoparticles (NPs). The function principle of the sensor is detecting the cumulative mass of NPs deposited on the cantilever surface as a shift in its resonant frequency. A self-sensing method with an integrated full Wheatstone bridge on the cantilever as a piezoresistive strain gauge is introduced for signal readout replacing optical sensing method. For trapping NPs to the cantilever surface, an electrostatic field is used. The calculated equivalent mass-induced resonant frequency shift due to NPs sampling is measured to be 11.78 ± 0.01 ng. The proposed sensor exhibits a mass sensitivity of 8.33 Hz/ng, a quality factor of 1,230.68 ± 78.67, and a temperature coefficient of the resonant frequency (TC f ) of −28.6 ppm/°C. These results and analysis indicate that miniaturized sensors based on self-sensing piezoresistive microcantilever can offer the performance to fulfill the requirements of real-time monitoring of NPs-exposed personnel.












Similar content being viewed by others
References
Balbus JM, Florini K, Denison RA, Walsh SA (2007) Protecting workers and the environment: an environmental NGO’s perspective on nanotechnology. J Nanopart Res 9(1):11–22
Black J, Elium A, White R, Apte M, Gundel L, Cambie R (2007) MEMS-enabled miniaturized particulate matter monitor employing 1.6 GHz aluminum nitride thin-film bulk acoustic wave resonator and thermophoretic precipitator. In: Proc IEEE Ultrasonics Symposium, pp 476–479
Craighead H (2007) Nanomechanical Systems: measuring more than mass. Nat Nanotechnol 2:18–19
Ekinci KL, Yang YT, Roukes ML (2004) Ultimate limits to inertial mass sensing based upon nanoelectromechanical systems. J Appl Phys 95:2682–2689
Elder A, Gelein R, Silva V, Feikert T, Opanashuk L, Carter J, Potter R, Maynard A, Ito Y, Finkelstein J, Oberdörster G (2006) Translocation of inhaled ultrafine manganese oxide particles to the central nervous system. Environ Health Perspect 114(8):1172–1178
Gwinn MR, Vallyathan V (2006) Nanoparticles: health effects—Pros and cons. Environ Health Perspect 114(2):1818–1825
Hajjam A, Wilson JC, Rahafrooz A (2010) Fabrication and characterization of resonant aerosol particle mass sensor. In: Proc 23rd IEEE Intern Conf Micro Electro Mechanical System (MEMS 2010), pp 863–866
Hajjam A, Wilson JC, Rahafrooz A, Pourkamali S (2011) Self-Sustained Micromechanical Resonant Particulate Microbalance/Counters. In: Proc 24th IEEE Intern Conf Micro Electro Mechanical System (MEMS 2011), pp 629–632
Ilic B, Krylov S, Kondratovich M, Craighead HG (2007) Optically actuated nanoelectromechanical oscillators. IEEE J Sel Top Quantum Electron 12(2):392–399
Lavrik NV, Sepaniak MJ, Datskos PG (2004) Cantilever transducers as a platform for chemical and biological sensors. Rev Sci Instrum 75(7):2229–2253
Lübbe J, Temmen M, Schnieder H, Reichling M (2011) Measurement and modelling of non-contact atomic force microscope cantilever properties from ultra-high vacuum to normal pressure conditions. Meas Sci Technol 22:055501 (6pp)
Marijnissen J, Gradoń L (2010) Nanoparticles in medicine and environment: inhalation and health effects. J Aerosol Med Pulm Drug Deliv 23(5):339–341
Merzsch S, Wasisto HS, Sökmen Ü, Waag A, Uhde E, Salthammer T, Peiner E (2010) Mass measurement of nanoscale aerosol particles using a piezoelectrically actuated resonant sensor. IEEE Sens Conf open poster
Merzsch S, Wasisto HS, Waag A, Kirsch I, Uhde E, Salthammer T, Peiner E (2011) Low-weight electrostatic sampler for airborne nanoparticles. In: Proc IEEE Sens Conf, pp 1177–1180
Nel A, Xia T, Mädler L, Li N (2006) Toxic potential of materials at the nanolevel. Science 311:622–627
Nordström M, Zauner DA, Calleja M, Hubner J, Boisen A (2007) Integrated optical readout for miniaturization of cantilever-based sensor system. Appl Phys Lett 91:103512
Paprotny I, Doering F, White RM (2010) MEMS particulate matter (PM) monitor for cellular deployment. In: Proc IEEE Sensors Conf, pp 2435–2440
Peiner E, Balke M, Doering L (2008) Slender tactile sensor for contour and roughness measurements within deep and narrow holes. IEEE Sens J 8(12):1960–1967
Peiner E, Doering L, Stranz A (2010) Surface finish improvement of deep micro bores monitored using an active MEMS cantilever probe. In: Proc Intern Conf Industrial Technol, pp 297–302 (IEEE-ICIT 2010)
Pethig R (2010) Review article—Dielectrophoresis: status of the theory, technology, and applications. Biomicrofluidics 4:022811
Sandberg R, Svendsen W, Molhave K, Boisen A (2005) Temperature and pressure dependence of resonant in multi-layer microcantilevers. J Micromech Microeng 15:1454–1458
Sökmen Ü, Stranz A, Waag A, Ababneh A, Seidel H, Schmid U, Peiner E (2010) Evaluation of resonating Si cantilevers sputter-deposited with AlN piezoelectric thin films for mass sensing applications. J Micromech Microeng 20:064007
Wasisto HS, Merzsch S, Stranz A, Waag A, Kirsch I, Uhde E, Salthammer T, Peiner E (2011a) A resonant cantilever sensor for monitoring airborne nanoparticles. In: Proc 16th Intern Conf Solid-State Sens, Actuat Microsyst, pp 1116–1119 (Transducers’11)
Wasisto HS, Merzsch S, Waag A, Kirsch I, Uhde E, Salthammer T, Peiner E (2011b) Enhanced airborne nanoparticles mass sensing using a high-mode resonant silicon cantilever sensor. In: Proc IEEE Sens Conf, pp 736–739
Wasisto HS, Doering L, Merzsch S, Waag A, Uhde E, Peiner E (2011c) Self-exciting and self-sensing resonant cantilever sensors for improved monitoring of airborne nanoparticles exposure. In: Proc IEEE Sens Conf, pp 728–731
Zinoviev K, Dominguez C, Plaza JA, Busto VJC, Lechuga LM (2006) A novel optical waveguide microcantilever sensor for the detection of nanomechanical forces. J Lightwave Technol 24(5):2132–2138
Acknowledgments
The authors would like to thank K. H. Lachmund, J. Arens, and D. Rümmler for their valuable technical assistances. This work is performed in the collaborative project “NanoExpo” funded by the German Federal Ministry of Education and Research (BMBF) within the cluster “NanoCare” under no. 03X0098A.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Wasisto, H.S., Merzsch, S., Waag, A. et al. Determination of exposure to engineered carbon nanoparticles using a self-sensing piezoresistive silicon cantilever sensor. Microsyst Technol 18, 905–915 (2012). https://doi.org/10.1007/s00542-011-1405-9
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00542-011-1405-9