Advanced human heat exposure sensing using two cylinder anemometer and radiometer: introducing CARla

  • Original Paper
  • Published:
International Journal of Biometeorology Aims and scope Submit manuscript

Abstract

The negative health impacts of extreme heat exposure can be mitigated by incorporating hyperlocal biometeorological observations into heat action planning, emergency responses, and heat-reducing urban design. A significant portion of outdoor human heat exposure is radiative, but it is often overlooked due to the absence of affordable, accurate, and user-friendly sensors. We developed a two cylinder anemometer and radiometer (CARla) consisting of unheated and heated gray components, which quantifies wind speed and the total radiation absorbed by the human body. The spectral properties of the gray coating match the standard short- and longwave absorptivity used in mean radiant temperature (MRT) calculations. We optimized the geometrical parameters of the cylinders, including height, wall thickness, and side-mounting, to minimize errors in MRT and wind speed measurements. Experiments were conducted across 15 outdoor sites in Tempe, Arizona, during the record-setting heat wave from August to October 2024. Results demonstrated that the MRT measured using CARla closely matched those measured using 3-way net radiometers. The average error in MRT using the new compact system was 1.3 ± 2.2 °C across a wide MRT range (20 to 75 °C). CARLa represents a significant improvement compared to other low-cost radiometers. The average difference between the CARla and ultrasonic anemometers for wind speed was − 0.05 ± 0.36 m·s−1 in the 0.25 to 3 m·s−1 range, comparable to standard low-cost anemometers. We integrated the CARla sensor with an Arduino-based logger, creating a cost-effective and accurate tool for broadly characterizing human exposure to extreme heat.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+ Basic
$34.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or eBook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

Data availability

All data is included in the manuscript and supporting AQ information.

References

  • ASTM E230/E230-17 (2017) Standard Specification for Temperature-Electromotive Force (emf) Tables for Standardized Thermocouples

  • Bergman TL, Lavine AS, Incropera FP, Dewitt DP (2011) Fundamentals of heat and mass transfer. John Wiley & Sons, Inc, New York

    Google Scholar 

  • Brown RD (2019) Correcting the Error in Measuring Radiation received by a person: introducing Cylindrical Radiometers. Sensors 19:5085

    Google Scholar 

  • Brown RD, Gillespie TJ (1986) Estimating outdoor thermal comfort using a cylindrical radiation thermometer and an energy budget model. Int J Biometeorol 30:43–52

    CAS  Google Scholar 

  • Budd GM (2008) Wet-bulb globe temperature (WBGT) - its history and its limitations. J Sci Med Sport 11:20

    Google Scholar 

  • Cureau RJ, Pigliautile I, Pisello AL (2022) A new wearable system for sensing outdoor environmental conditions for monitoring hyper-microclimate. Sensors 22:502

    CAS  Google Scholar 

  • De Dear R (1988) Ping-pong globe thermometers for mean radiant temperatures. H V Eng 60:10–11

    Google Scholar 

  • Dzyuban Y, Hondula DM, Vanos JK et al (2022) Evidence of alliesthesia during a neighborhood thermal walk in a hot and dry city. Sci Total Environ 834:155294

    CAS  Google Scholar 

  • Fiala D, Havenith G (2015) Modelling human heat transfer and temperature regulation. The mechanobiology and mechanophysiology of military-related injuries. Springer, pp 265–302

    Google Scholar 

  • Fiala D, Lomas KJ, Stohrer M (1999) A computer model of human thermoregulation for a wide range of environmental conditions: the passive system. J Appl Physiol

    Google Scholar 

  • Hilpert R (1933) Heat transfer from cylinders. Forsch Geb Ingenieurwes 4:215

    CAS  Google Scholar 

  • Höppe P (1992) Ein Neues Verfahren Zur Bestimmung Der Mittleren Strahlungstemperatur Im Freien. Wetter und Leben 44:147–151

    Google Scholar 

  • Joshi A, Viswanathan SH, Jaiswal AK et al (2024) Characterization of human extreme heat exposure using an outdoor thermal manikin. Sci Total Environ 923:171525

    CAS  Google Scholar 

  • Kántor N, Unger J (2011) The most problematic variable in the course of human-biometeorological comfort assessment—the mean radiant temperature. Cent Eur J Geosci 3:90–100

    Google Scholar 

  • Karanja J, Vanos J, Joshi A et al (2024) Impact of tent shade on heat exposures and simulated heat strain for people experiencing homelessness. Int J Biometeorol 1–14

  • Kenny NA, Warland JS, Brown RD, Gillespie TJ (2008) Estimating the radiation absorbed by a human. Int J Biometeorol 52:491–503

    Google Scholar 

  • Kulkarni KK, Schneider FA, Gowda T et al (2022) MaRTiny—A low-cost Biometeorological sensing device with Embedded Computer Vision for Urban Climate Research. Front Environ Sci 10:866240

    Google Scholar 

  • Lau KK-L, Shi Y, Ng EY-Y (2019) Dynamic response of pedestrian thermal comfort under outdoor transient conditions. Int J Biometeorol 63:979–989

    Google Scholar 

  • Lindner-Cendrowska K, Kuchcik M (2024) The impact of wind speed measurement method on MRT and PET values in limited air flow conditions on warm, sunny days. Int J Biometeorol 68:807–810

    Google Scholar 

  • Maricopa County Department of Public Health (2023) 2022 Heat Deaths Report. Phoenix

  • Middel A, Krayenhoff ES (2019) Micrometeorological determinants of pedestrian thermal exposure during record-breaking heat in Tempe, Arizona: introducing the MaRTy observational platform. Sci Total Environ 687:137–151

    CAS  Google Scholar 

  • Nakayoshi M, Kanda M, de Dear R (2015) Globe Anemo-Radiometer. Bound Layer Meteorol 155:209–227

    Google Scholar 

  • Nakayoshi M, Kanda M, Shi R, de Dear R (2015) Outdoor thermal physiology along human pathways: a study using a wearable measurement system. Int J Biometeorol 59:503–515

    Google Scholar 

  • Parsons K (2014) Human thermal environments: the effects of hot, moderate, and cold environments on human health, comfort, and performance. CRC

    Google Scholar 

  • Parsons K (2019) Human heat stress. CRC

    Google Scholar 

  • Peng Z, Bardhan R, Ellard C, Steemers K (2022) Urban climate walk: a stop-and-go assessment of the dynamic thermal sensation and perception in two waterfront districts in Rome, Italy. Build Environ 221:109267

    Google Scholar 

  • Rykaczewski K, Bartels L, Martinez DM, Viswanathan SH (2022) Human body radiation area factors for diverse adult population. Int J Biometeorol 66:2357–2367

    Google Scholar 

  • Rykaczewski K, Vanos JK, Middel A (2022) Anisotropic radiation source models for computational thermal manikin simulations based on common radiation field measurements. Build Environ 208:108636

    Google Scholar 

  • Rykaczewski K, Joshi A, Viswanathan SH et al (2024) A simple three-cylinder radiometer and low-speed anemometer to characterize human extreme heat exposure. Int J Biometeorol 68:1081–1092

    Google Scholar 

  • Staiger H, Matzarakis A (2020) Accuracy of mean radiant temperature derived from active and passive radiometry. Atmos (Basel) 11:805

    CAS  Google Scholar 

  • Thorsson S, Lindberg F, Eliasson I, Holmer B (2007) Different methods for estimating the mean radiant temperature in an outdoor urban setting. Int J Climatol 27:1983–1993

    Google Scholar 

  • Vanos JK, Rykaczewski K, Middel A et al (2021) Improved methods for estimating mean radiant temperature in hot and sunny outdoor settings. Int J Biometeorol 65:967–983

    Google Scholar 

  • Vasilikou C, Nikolopoulou M (2020) Outdoor thermal comfort for pedestrians in movement: thermal walks in complex urban morphology. Int J Biometeorol 64:277–291

    Google Scholar 

  • Viswanathan SH, Martinez DM, Bartels L et al (2023) Impact of human body shape on forced convection heat transfer. Int J Biometeorol 67:865–873

    Google Scholar 

Download references

Acknowledgements

Authors gratefully acknowledge the use of spectroscopy equipment within the Eyring Center for Solid State Science at Arizona State University.

Funding

This research was supported by the National Science Foundation Leading Engineering for America’s Prosperity, Health, and Infrastructure (LEAP HI) #2152468 award. Dr. Sylwester Wereski’s participation in the research was possible thanks to funding from the National Science Center in Poland under the MINIATURA 5 grant “The occurrence of strong heat stress in hot and dry climate condition” (2021/05/X/ST10/00587).

Author information

Authors and Affiliations

Authors

Contributions

KR: conceptualization, experiments, analysis; AJ, SHV, SW: field experiments and analysis; KS: field experiments and optical property characterization; SSG, MP, ID, EP, MG, GP, SW: fabrication, wind tunnel experiments and analysis; JKV and AM: analysis, conceptualization; All authors contributed to manuscript writing and editing; All authors read and approved the final manuscript.

Corresponding author

Correspondence to Konrad Rykaczewski.

Ethics declarations

Conflicts of interest

None.

Ethics approval

Nothing to declare.

Consent for publication

Nothing to declare.

Consent to participate

Nothing to declare.

Declaration of generative AI and AI-assisted technologies in the writing process

During the preparation of this work the author(s) used ChatGPT in order to improve the manuscript draft. After using this tool/service, the author(s) reviewed and edited the content as needed and take(s) full responsibility for the content of the publication.

Additional information

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Below is the link to the electronic supplementary material.

ESM 1

(PDF 1.35 MB)

Rights and permissions

Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Rykaczewski, K., Joshi, A., Viswanathan, S.H. et al. Advanced human heat exposure sensing using two cylinder anemometer and radiometer: introducing CARla. Int J Biometeorol 69, 835–848 (2025). https://doi.org/10.1007/s00484-025-02860-4

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00484-025-02860-4

Keywords