Skip to main content

Advertisement

Log in

Resurfacing knee arthroplasty in patients with allergic sensitivity to metals

  • Original Article
  • Published:
Archives of Orthopaedic and Trauma Surgery Aims and scope Submit manuscript

Abstract

Background. The problem of metal sensitivity (Ni, Cr, and Co) in arthroplasty is still unsolved. To prevent the risk of allergy in cases with proved metal allergy in an epicutaneous test, a Natural Knee total knee arthroplasty, made totally from titanium (Ti-6Al-4V) and polyethylene, can be implanted. The results of this device have to be compared to the results of normal knee arthroplasty designed with a femoral component out of CrCoNi alloy. The mechanical resistance of this alloy is much higher than that of titanium, and therefore it is the standard for the femoral components of most knee-resurfacing devices.

Methods. Thirty-five patients with a titanium Natural Knee were examined retrospectively after a mean follow-up of 2 years and 5 months (range 6 months to 5 years and 4 months). In comparison, 36 patients with a Genesis-I knee with a CrCoNi alloy femoral component were studied after a mean follow-up of 2 years and 4 months (range 8 months to 6 years and 2 months).

Results. In spite of the lower mechanical resistance of titanium, the Natural Knee showed better results (knee score 84.1 points, function score 77.7 points, HSS score 80.1 points, 82.9% excellent and good results) than the Genesis-I knee (knee score 80.6 points, function score 76.4 points, HSS score 76.4 points, 68.5% excellent and good results), although these differences had no statistical significance.

Conclusions. The titanium Natural Knee prosthesis has proven to be a reliable knee joint replacement in the medium term.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Electronic Publication

Rights and permissions

Reprints and permissions

About this article

Cite this article

Pellengahr, .C., Mayer, .W., Maier, .M. et al. Resurfacing knee arthroplasty in patients with allergic sensitivity to metals. Arch Orthop Trauma Surg 123, 139–143 (2003). https://doi.org/10.1007/s00402-002-0429-0

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00402-002-0429-0

Navigation