Skip to main content
Log in

Visualisation of intracerebral haemorrhage with flat-detector CT compared to multislice CT: results in 44 cases

  • Computer Tomography
  • Published:
European Radiology Aims and scope Submit manuscript

Abstract

The aim of the study was to test the reliability of intracerebral haemorrhage (ICH) detection with C-arm-mounted flat-detector computed tomography (FD-CT) in the angio suite as compared to multislice CT (MSCT). In this study 44 patients with 45 ICH were included. All patients were investigated with MSCT and FD-CT during angiographic evaluation. As a control group we included 16 patients without ICH. In each haematoma we assessed volumetric data of the ICH and counted the numbers of ICH-positive slices. Using interobserver ratings, we additionally investigated the potential of FD-CT to serve as a diagnostic tool to detect ICH. In FD-CT three haematomas were not detected because of motion and beam-hardening artefacts in the region close to the skull base. The r value for the degree of interobserver agreement for the number of slices was 0.95 for MSCT and 0.94 for FD-CT. Measurements of the area and the calculated volume of the ICH showed high inter- and intraobserver agreement. Our results indicate that FD-CT is a helpful tool in the daily emergency management of ICH patients as detection of ICH was found to be nearly as reliable as in MSCT. Limitations of this technology are motion and beam-hardening artefacts that may mask small haematomas located in the posterior fossa or the skull base.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

References

  1. Sahni R, Weinberger J (2007) Management of intracerebral hemorrhage. Vasc Health Risk Manag 3(5):701–709

    CAS  PubMed  Google Scholar 

  2. Hänggi D, Steiger HJ (2008) Spontaneous intracerebral haemorrhage in adults: a literature overview. Acta Neurochir 150:371–379

    Article  Google Scholar 

  3. Brisman JL, Niimi Y, Song JK, Berenstein A (2005) Aneurysmal rupture during coiling: low incidence and good outcomes at a single large volume centre. Neurosurgery 57:1103–1109

    Article  PubMed  Google Scholar 

  4. Carvi y Nievas M, Haas E, Höllerhage HG (2007) Severe intracranial bleedings during endovascular procedures: outcome of surgically treated patients. Neurol Res 29(1):81–90

    Article  PubMed  Google Scholar 

  5. Kalender WA, Kyriakou Y (2007) Flat-detector computed tomography (FD-CT). Eur Radiol 17:2767–2779

    Article  PubMed  Google Scholar 

  6. Schumacher M, Kutluk K, Ott D (1989) Digital rotational radiography in neuroradiology. Am J Neuroradiol 10:644–649

    CAS  PubMed  Google Scholar 

  7. Kalender WA (2003) [The use of flat-panel detectors for CT imaging]. Radiologe 43:379–387

    Article  CAS  PubMed  Google Scholar 

  8. Loose R, Wucherer M, Brunner T, Adamus R, Simmler R (2005) Visualization of 3D low contrast objects by CT cone-beam reconstruction of a rotational angiography with a dynamic solid body detector. Roefo S1:PO 160

  9. Heran NS, Song JK, Namba K, Smith W, Niimi Y, Berenstein A (2006) The utility of DynaCT in neuroendovascular procedures. Am J Neuroradiol 27:330–332

    CAS  PubMed  Google Scholar 

  10. Arakawa H, Marks MP, Do HM, Bouley DM, Strobel N, Moore T, Fahrig R (2008) Experimental study of intracranial hematoma detection with flat panel detector C-arm CT. Am J Neuroradiol 29(4):766–772

    Article  CAS  PubMed  Google Scholar 

  11. Kwak R, Kadoya S, Suzuke T (1983) Factors affecting the prognosis of thalamic hemorrhage. Stroke 14:493–500

    CAS  PubMed  Google Scholar 

  12. Richter G, Engelhorn T, Struffert T, Doelken M, Ganslandt O, Hornegger J, Kalender WA, Doerfler A (2007) Flat panel detector angiographic CT for stent-assisted coil embolization of broad-based cerebral aneurysms. Am J Neuroradiol 28(19):1902–1908

    Article  CAS  PubMed  Google Scholar 

  13. Engelhorn T, Rennert J, Richter G, Struffert T, Ganslandt O, Doerfler A (2007) Myelography using flat panel volumetric computed tomography: a comparative study in patients with lumbar spinal stenosis. Spine 32(18):E523–E527

    Article  PubMed  Google Scholar 

  14. Doelken M, Struffert T, Richter G, Engelhorn T, Nimsky C, Ganslandt O, Hammen T, Doerfler A (2008) Flat-panel detector volumetric CT for visualization of subarachnoid hemorrhage and ventricles: preliminary results compared to conventional CT. Neuroradiology 50(6):517–523

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Tobias Struffert.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Struffert, T., Richter, G., Engelhorn, T. et al. Visualisation of intracerebral haemorrhage with flat-detector CT compared to multislice CT: results in 44 cases. Eur Radiol 19, 619–625 (2009). https://doi.org/10.1007/s00330-008-1183-7

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00330-008-1183-7

Keywords

Navigation