Abstract
Due to its low cost, portability, and nonionizing radiation, quantitative ultrasound (QUS) of the heel is an alternative to the measurement with dual X-ray absorptiometry (DXA) in the evaluation of bone status. The objective of the study is to compare in asymptomatic postmenopausal women the ability of QUS and DXA to discriminate between those with and without prevalent vertebral fractures (VFs). The study cohort consists of a population of 295 postmenopausal women aged between 60 and 84 (mean age, weight and BMI of 66.3 years, 72.0 kg and 29.4 kg/m2, respectively). Lateral VFA images and scans of the lumbar spine and proximal femur were obtained by two technologists using a GE Healthcare Lunar Prodigy densitometer. VFs were defined using a combination of Genant semiquantitative (SQ) approach and morphometry. All women had a calcaneous QUS examination. The mean age of the women in our sample was 66.3 (±5.3) years, ranging from 60 to 84 years. Eighty-seven (29.3%) women had VFs Genant grade 2 and 3. Patients with VFs had an age and a number of years of menopause higher to those without VFs, but showed lower height, weight, and BMI. All densitometric and ultrasonometric measurements were significantly reduced in women with VFs. The intercorrelations of BMD at different sites were high, and the correlations of BUA with BMD were lower. BUA correlated weakly with total hip BMD (r = 0.36), lumbar spine BMD (r = 0.32), and much less with femur BMD (r = 0.30); all correlations were significant (P < 0.01). Analysis of the AUC for the ROC curves showed lumbar spine T-score below −2.5 to provide consistently the highest AUC (0.64). Age-adjusted ORs after correction for confounding variables (years of menopause, weight, height, and BMI) for QUS and BMD measurements showed that only lumbar spine T-score below −2.5 could predict significantly the presence of VFs (OR, 1.94; 95%CI, 1.02–3.41). Lumbar spine BMD (and not QUS) was able to discriminate asymptomatic postmenopausal women with prevalent VFs from women without VFs and independently contributed to determining the association with fracture. The combination of QUS and BMD did not improve the diagnostic ability of either individual technique.
Similar content being viewed by others
References
Blake GM, Fogelman I (2007) The role of DXA bone density scans in the diagnosis and treatment of osteoporosis. Postgrad Med J 83:509–517. doi:10.1136/pgmj.2007.057505
El Maghraoui A, Roux C (2008) DXA scanning in clinical practice. QJM 2008
Stewart A, Walker LG, Porter RW, Reid DM, Primrose WR (1999) Predicting a second hip fracture. J Clin Densitom 2:363–370. doi:10.1016/S1094-6950(06)60401-0
Durosier C, Hans D, Krieg MA, Schott AM (2006) Prediction and discrimination of osteoporotic hip fracture in postmenopausal women. J Clin Densitom 9:475–495. doi:10.1016/j.jocd.2006.06.002
El Maghraoui A, Koumba BA, Jroundi I, Achemlal L, Bezza A, Tazi MA (2005) Epidemiology of hip fractures in 2002 in Rabat, Morocco. Osteoporos Int 16:597–602. doi:10.1007/s00198-004-1729-8
Frost ML, Blake GM, Fogelman I (1999) Contact quantitative ultrasound: an evaluation of precision, fracture discrimination, age-related bone loss and applicability of the WHO criteria. Osteoporos Int 10:441–449. doi:10.1007/s001980050252
Gregg EW, Kriska AM, Salamone LM et al (1997) The epidemiology of quantitative ultrasound: a review of the relationships with bone mass, osteoporosis and fracture risk. Osteoporos Int 7:89–99. doi:10.1007/BF01623682
El Maghraoui A, Do Santos Zounon AA, Jroundi I et al (2005) Reproducibility of bone mineral density measurements using dual X-ray absorptiometry in daily clinical practice. Osteoporos Int 16:1742–1748. doi:10.1007/s00198-005-1916-2
El Maghraoui A, Achemlal L, Bezza A (2006) Monitoring of dual-energy X-ray absorptiometry measurement in clinical practice. J Clin Densitom 9:281–286. doi:10.1016/j.jocd.2006.03.014
El Maghraoui A, Guerboub AA, Achemlal L et al (2006) Bone mineral density of the spine and femur in healthy Moroccan women. J Clin Densitom 9:454–460. doi:10.1016/j.jocd.2006.07.001
El Maghraoui A, Guerboub AA, Mounach A et al (2007) Body mass index and gynecological factors as determinants of bone mass in healthy Moroccan women. Maturitas 56:375–382. doi:10.1016/j.maturitas.2006.10.004
Genant HK, Li J, Wu CY, Shepherd JA (2000) Vertebral fractures in osteoporosis: a new method for clinical assessment. J Clin Densitom 3:281–290. doi:10.1385/JCD:3:3:281
Sim MF, Stone MD, Phillips CJ et al (2005) Cost effectiveness analysis of using quantitative ultrasound as a selective pre-screen for bone densitometry. Technol Health Care 13:75–85
Frediani B, Acciai C, Falsetti P et al (2006) Calcaneus ultrasonometry and dual-energy X-ray absorptiometry for the evaluation of vertebral fracture risk. Calcif Tissue Int 79:223–229. doi:10.1007/s00223-005-0098-4
Gluer MG, Minne HW, Gluer CC et al (2005) Prospective identification of postmenopausal osteoporotic women at high vertebral fracture risk by radiography, bone densitometry, quantitative ultrasound, and laboratory findings: results from the PIOS study. J Clin Densitom 8:386–395. doi:10.1385/JCD:8:4:386
Gonnelli S, Cepollaro C, Gennari L et al (2005) Quantitative ultrasound and dual-energy X-ray absorptiometry in the prediction of fragility fracture in men. Osteoporos Int 16:963–968. doi:10.1007/s00198-004-1771-6
Schott AM, Kassai Koupai B, Hans D et al (2004) Should age influence the choice of quantitative bone assessment technique in elderly women? The EPIDOS study. Osteoporos Int 15:196–203. doi:10.1007/s00198-003-1505-1
Gluer CC, Eastell R, Reid DM et al (2004) Association of five quantitative ultrasound devices and bone densitometry with osteoporotic vertebral fractures in a population-based sample: the OPUS Study. J Bone Miner Res 19:782–793. doi:10.1359/JBMR.040304
Knapp KM, Blake GM, Fogelman I, Doyle DV, Spector TD (2002) Multisite quantitative ultrasound: Colles’ fracture discrimination in postmenopausal women. Osteoporos Int 13:474–479. doi:10.1007/s001980200057
Hartl F, Tyndall A, Kraenzlin M et al (2002) Discriminatory ability of quantitative ultrasound parameters and bone mineral density in a population-based sample of postmenopausal women with vertebral fractures: results of the Basel Osteoporosis Study. J Bone Miner Res 17:321–330. doi:10.1359/jbmr.2002.17.2.321
Frost ML, Blake GM, Fogelman I (2002) A comparison of fracture discrimination using calcaneal quantitative ultrasound and dual X-ray absorptiometry in women with a history of fracture at sites other than the spine and hip. Calcif Tissue Int 71:207–211. doi:10.1007/s00223-001-2074-y
Frost ML, Blake GM, Fogelman I (2001) Does the combination of quantitative ultrasound and dual-energy X-ray absorptiometry improve fracture discrimination? Osteoporos Int 12:471–477. doi:10.1007/s001980170092
Briot K, Roux C (2005) What is the role of DXA, QUS and bone markers in fracture prediction, treatment allocation and monitoring? Best Pract Res Clin Rheumatol 19:951–964. doi:10.1016/j.berh.2005.06.004
Cummings SR, Black DM, Nevitt MC et al (1993) Bone density at various sites for prediction of hip fractures. The Study of Osteoporotic Fractures Research Group. Lancet 341:72–75. doi:10.1016/0140-6736(93)92555-8
Pinheiro MM, Castro CH, Frisoli A Jr, Szejnfeld VL (2003) Discriminatory ability of quantitative ultrasound measurements is similar to dual-energy X-ray absorptiometry in a Brazilian women population with osteoporotic fracture. Calcif Tissue Int 73:555–564. doi:10.1007/s00223-002-1096-4
Peretz A, De Maertelaer V, Moris M, Wouters M, Bergmann P (1999) Evaluation of quantitative ultrasound and dual X-Ray absorptiometry measurements in women with and without fractures. J Clin Densitom 2:127–133. doi:10.1385/JCD:2:2:127
Trone DW, Kritz-Silverstein D, von Muhlen DG, Wingard DL, Barrett-Connor E (2007) Is radiographic vertebral fracture a risk factor for mortality? Am J Epidemiol 166:1191–1197. doi:10.1093/aje/kwm206
Nevitt MC, Cummings SR, Stone KL et al (2005) Risk factors for a first-incident radiographic vertebral fracture in women > or = 65 years of age: the study of osteoporotic fractures. J Bone Miner Res 20:131–140
Frost ML, Blake GM, Fogelman I (2001) Quantitative ultrasound and bone mineral density are equally strongly associated with risk factors for osteoporosis. J Bone Miner Res 16:406–416. doi:10.1359/jbmr.2001.16.2.406
Pearson D, Masud T, Sahota O, Earnshaw S, Hosking D (2003) A comparison of calcaneal dual-energy X-ray absorptiometry and calcaneal ultrasound for predicting the diagnosis of osteoporosis from hip and spine bone densitometry. J Clin Densitom 6:345–352. doi:10.1385/JCD:6:4:345
Wuster C, Heilmann P, Pereira-Lima J, Schlegel J, Anstatt K, Soballa T (1998) Quantitative ultrasonometry (QUS) for the evaluation of osteoporosis risk: reference data for various measurement sites, limitations and application possibilities. Exp Clin Endocrinol Diabetes 106:277–288
Damiano J, Kolta S, Porcher R, Tournoux C, Dougados M, Roux C (2006) Diagnosis of vertebral fractures by vertebral fracture assessment. J Clin Densitom 9:66–71. doi:10.1016/j.jocd.2005.11.002
Chapurlat RD, Duboeuf F, Marion-Audibert HO, Kalpakcioglu B, Mitlak BH, Delmas PD (2006) Effectiveness of instant vertebral assessment to detect prevalent vertebral fracture. Osteoporos Int 17:1189–1195. doi:10.1007/s00198-006-0121-2
Clowes JA, Eastell R, Peel NF (2005) The discriminative ability of peripheral and axial bone measurements to identify proximal femoral, vertebral, distal forearm and proximal humeral fractures: a case control study. Osteoporos Int 16:1794–1802. doi:10.1007/s00198-005-1931-3
Acknowledgments
The authors thank the staff at the bone densitometer centre and all the rheumatologists that participated in the study. We thank Dr. Rabea Alaoui and Dr. Abdellatif Saada for their help. This research was supported by a Grant of Sanofi-Aventis, Morocco.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
El Maghraoui, A., Morjane, F., Mounach, A. et al. Performance of calcaneus quantitative ultrasound and dual-energy X-ray absorptiometry in the discrimination of prevalent asymptomatic osteoporotic fractures in postmenopausal women. Rheumatol Int 29, 551–556 (2009). https://doi.org/10.1007/s00296-008-0751-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00296-008-0751-0