Risk factors in cutout of sliding hip screw in intertrochanteric fractures: an evaluation of 937 patients

International Orthopaedics Aims and scope Submit manuscript

An Erratum to this article was published on 13 November 2011

Abstract

The aim of this study was designed to assess the risk factors of lag-screw cutout in the treatment of intertrochanteric fracture with a dynamic hip screw (DHS). From 2003 to 2007, 1,150 patients who had acute unilateral intertrochanteric fractures of the femur were enrolled to the study. All fractures were managed by closed reduction and internal fixation with 135° DHS devices. Patient demographics, fracture patterns, reduction and fixation and perioperative course parameters were all recorded. The follow-up period was 38 months on average (range 16–60 months). Finally, 937 patients were available for evaluation of final results in which we focused on lag-screw cutout. Excluding complications not related to screw position, 64 patients (6.8%) with screw cutout were encountered, and the remaining 873 patients had uneventful union, with the average union time of 17.5 weeks (range15–24 weeks). Upon analysis with logistic regression, the tip−apex distance (TAD) was shown to be the most important predictive factor for cutout, followed by screw position, fracture pattern, reduction and patient age. In order to decrease the risk of lag-screw cutout, it is important to ensure good fracture reduction and to place the lag screw in either the middle/middle or inferior/middle position with appropriate TAD.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2

References

  1. American Society of Anesthesiologists (2009) New classification of physical status. Anesthesiology 24:111

    Google Scholar 

  2. Baumgaertner MR, Curtin SL, Lindskog DM, Keggi JM (1995) The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip. J Bone Joint Surg Am 77:1058–1064

    PubMed  CAS  Google Scholar 

  3. Baumgaertner MR, Solberg BD (1997) Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip. J Bone Joint Surg Br 79:969–971

    Article  PubMed  CAS  Google Scholar 

  4. Bonamo JJ, Accettola AB (1982) Treatment of intertrochanteric fractures with a sliding nail-plate. J Trauma 22:205–215

    Article  PubMed  CAS  Google Scholar 

  5. Cleveland M, Bosworth DM, Thompson FR, Wilson HJ Jr, Ishizuka T (1959) A ten-year analysis of intertrochanteric fractures of the femur. J Bone Joint Surg Am 41:1399–1408

    PubMed  Google Scholar 

  6. Davis TR, Sher JL, Horsman A, Simpson M, Porter BB, Checketts RG (1990) Intertrochanteric femoral fractures: mechanical failures after internal fixation. J Bone Joint Surg Br 72:26–31

    PubMed  CAS  Google Scholar 

  7. Evans EM (1951) Trochanteric fractures: a review of 110 cases treated by nail-plate fixation. J Bone Joint Surg Br 33:192–204

    Google Scholar 

  8. Garden RS (1961) Low-angle fixation in fractures of the femoral neck. J Bone Joint Surg Br 43:647–663

    Google Scholar 

  9. Kaufer H, Mattews LS, Sonstegard D (1974) Stable fixation of intertrochanteric fracture. A biomechanical evaluation. J Bone Joint Surg Am 56:899–907

    PubMed  CAS  Google Scholar 

  10. Kyle RF (1994) Fractures of the proximal part of the femur. J Bone Joint Surg Am 76:924–950

    Google Scholar 

  11. Kyle RF, Gustilo RB, Premer RF (1976) Analysis of six hundred and twenty-two intertrochanteric hip fractures. A retrospective and prospective study. J Bone Joint Surg Am 61:216–221

    Google Scholar 

  12. Geller JA, Saifi C, Morrison TA, Macaulay W (2009) Tip-apex distance of intramedullary devices as a predictor of cut-out failure in the treatment of peritrochanteric elderly hip fractures. Int Orthop. doi:10.1007/s00264-009-0837-7

    PubMed  Google Scholar 

  13. Larsson S, Friberg S, Hansson LI (1990) Trochanteric fractures. Influence of reduction and implant position on impaction and complications. Clin Orthop 259:130–139

    PubMed  Google Scholar 

  14. Madsen JE, Naess L, Aune AK, Alho A, Ekeland A, Strømsøe K (1998) Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures. A comparative study with Gamma nail and compression hip screw. J Orthop Trauma 12:241–248

    Article  PubMed  CAS  Google Scholar 

  15. Mainds CC, Newman RJ (1989) Implant failures in patients with proximal fractures of the femur treated with a sliding screw device. Injury 20:98–100

    Article  PubMed  CAS  Google Scholar 

  16. Liu M, Yang Z, Pei F, Huang F, Chen S, Xiang Z (2009) A meta-analysis of the Gamma nail and dynamic hip screw in treating peritrochanteric fractures. Int Orthop. doi:10.1007/s00264-009-0783-4, April Online Published

    Google Scholar 

  17. Parker MJ (1992) Cutting-out of the dynamic hip screw related to its position. J Bone Joint Surg Br 74:625

    PubMed  CAS  Google Scholar 

  18. Nordin S, Zulkifli O, Faisham WI (2001) Mechanical failure of dynamic Hip Screw (DHS) fixation in intertrochanteric fracture of the femur. Med J Malaysia 56:12–17

    PubMed  Google Scholar 

  19. Parker MJ, Handoll HH (2008) Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults. Cochrane Database Syst Rev 16(3):CD000093

    Google Scholar 

  20. Parker MJ (1993) Valgus reduction of trochanteric fractures. Injury 24:313–316

    Article  PubMed  CAS  Google Scholar 

  21. Pervez H, Parker MJ, Vowler S (2004) Prediction of fixation failure after sliding hip screw fixation. Injury 35:994–998

    Article  PubMed  Google Scholar 

  22. Gundle R, Gargan MF, Simpson AH (1995) How to minimize failure of fixation of unstable intertrochanteric fractures. Injury 26:611–614

    Article  PubMed  CAS  Google Scholar 

  23. Saarenpää I, Heikkinen T, Ristiniemi J, Hyvönen P, Leppilahti J, Jalovaara P (2009) Functional comparison of the dynamic hip screw and the Gamma locking nail in trochanteric hip fractures: a matched-pair study of 268 patients. Int Orthop 33:255–260

    Article  PubMed  Google Scholar 

  24. Simpson AH, Varty K, Dodd CAF (1989) Sliding hip screw: modes of failure. Injury 20:227–231

    Article  PubMed  CAS  Google Scholar 

  25. Wu CC, Shih CH, Lee MY, MS TCL (1996) Biomechanical analysis of location of lag screw of a dynamic hip screw in treatment of unstable intertrochanteric fracture. J Trauma 41:699–702

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Fang-Yao Chiu.

Additional information

An erratum to this article can be found at http://dx.doi.org/10.1007/s00264-011-1405-5

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hsueh, KK., Fang, CK., Chen, CM. et al. Risk factors in cutout of sliding hip screw in intertrochanteric fractures: an evaluation of 937 patients. International Orthopaedics (SICOT) 34, 1273–1276 (2010). https://doi.org/10.1007/s00264-009-0866-2

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00264-009-0866-2

Keywords

Navigation