Skip to main content

Advertisement

Log in

Determination of right ventricular ejection fraction from reprojected gated blood pool SPET: comparison with first-pass ventriculography

  • Original Article
  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract.

Gated blood pool (GBP) studies are widely available and relatively inexpensive. We have previously published a simple and convenient method for measuring left ventricle ejection fraction (EF) with increased accuracy from single-photon emission tomography (SPET) GBP scans. This paper describes an extension of this method by which right ventricular EF may also be measured. Gated SPET images of the blood pool are acquired and re-oriented in short-axis slices. Counts from the left ventricle are excluded from the short-axis slices, which are then reprojected to give horizontal long-axis images. Time-activity curves are generated from each pixel around the right ventricle, and an image is created with non-ventricular pixels "greyed out". This image is used as a guide in drawing regions of interest around the right ventricle on the end-diastolic and end-systolic long-axis images. In 28 patients, first-pass ventriculography studies were acquired followed by SPET GBP scans. The first-pass images were analysed a total of four times by two observers and the SPET images were analysed three times each by two observers. The agreement between the two techniques was good, with a correlation coefficient of 0.72 and a mean absolute difference between first-pass and reprojected SPET EFs of 4.8 EF units. Only four of the 28 patients had a difference of greater than 8 EF units. Variability was also excellent for SPET right ventricular EF values. Intra-observer variability was significantly lower for SPET than for first-pass EFs: standard error of the estimate (SEE)=5.1 and 7.3 EF units, respectively (P<0.05). Inter-observer variability was comparable in the two techniques (SEE=5.2 and 6.9 EF units for SPET and first-pass ventriculography, respectively).

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received 1 November 2000 and in revised form 18 January 2001

Electronic Publication

Rights and permissions

Reprints and permissions

About this article

Cite this article

Bartlett, M., Seaton, D., McEwan, L. et al. Determination of right ventricular ejection fraction from reprojected gated blood pool SPET: comparison with first-pass ventriculography. Eur J Nucl Med 28, 608–613 (2001). https://doi.org/10.1007/s002590100503

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002590100503

Navigation