A multihospital survey of radiation exposure and image quality in pediatric fluoroscopy

  • ORIGINAL ARTICLE
  • Published:
Pediatric Radiology Aims and scope Submit manuscript

Abstract

Background. Traditionally, pediatric radiologists have been advocates of fluoroscopy systems that provide diagnostic images at the lowest possible radiation dose to the pediatric patient. Manufacturers of fluoroscopic equipment vary as to their claims of “low radiation“ exposures.¶Objectives. To obtain comparative data on radiation exposure and image quality from four pediatric hospitals, across variants of fluoroscopic equipment (such as pulsed versus continuous fluoroscopy).¶Materials and methods. Images were acquired from phantoms that simulated the size of a 3-year-old child. Phantom results, both stationary and rotating dynamic, were evaluated for radiation exposure and for image resolution of high- and low-contrast objects.¶Results. Radiation exposure from the four fluoro units varied widely; the lowest-dose selectable fluoro mode produced exposures varying between 34 and 590 mrads/min among the four fluoro units, and the highest-dose selectable fluoro mode produced 540–2230 mrads/min. The lowest radiation exposures were produced by pulsed fluoro units, and the very lowest radiation exposure was produced by a fluoroscope that had been especially optimized for pediatric imaging. There was only a small variation in image quality among the hospitals for visualization of stationary objects. A wide variability was noted for detection of objects on the moving phantom.¶Conclusions. The variability in the number of detected objects was considerably smaller than the variability in radiation exposure. Pulsed fluoroscopy provides improved resolution for moving objects. Optimization of one hospital's fluoroscope especially for pediatric imaging produced the best ratio of image quality to radiation exposure.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 29 June 1999/Accepted: 23 August 1999

Rights and permissions

Reprints and permissions

About this article

Cite this article

Brown, P., Silberberg, P., Thomas, R. et al. A multihospital survey of radiation exposure and image quality in pediatric fluoroscopy. Pediatric Radiology 30, 236–242 (2000). https://doi.org/10.1007/s002470050729

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002470050729

Keywords

Navigation