Abstract
A system for on-line preconcentration and determination of lead by flame atomic absorption spectrometry (FAAS) was proposed. It was based on the sorption of lead(II) ions on a minicolumn of polyurethane foam loaded with 2-(2-thiazolylazo)-5-dimethylaminophenol (TAM). The optimisation step was carried out using two-level full factorial and Doehlert designs for the determination of the optimum conditions for lead preconcentration. The proposed procedure allowed the determination of lead with a detection limit of 2.2 μg L−1, and a precision, calculated as relative standard deviation (RSD), of 2.4 and 6.8 for a lead concentration of 50.0 and 10.0 μg L−1, respectively. A preconcentration factor of 45 and a sampling frequency of 27 samples per hour were obtained. The recovery achieved for lead determination in the presence of several cations demonstrated that this procedure has enough selectivity for analysis of environmental samples. The validation was carried out by analysis of certified reference material. This procedure was applied to lead determination in natural food.
Similar content being viewed by others
References
Neto BB, Scarminio IS, Bruns RE (2001) Como Fazer Experimentos, Unicamp, Campinas, Brazil
Montgomery DC (1997) Design and analysis of experiments, 4th edn. Wiley, New York
Bayne CK, Rubin IB (1986) Practical experimental designs and optimization methods for chemists. VCH, Weinheim
Deming SN, Morgan SL (1987) Experimental design: a chemometrics approach. Elsevier, Amsterdam
Box GEP, Hunter WG, Hunter JS (1978) Statistics for experimenters. Wiley, Chichester
Beveridge GSG, Schechter, (1971) Optimization: theory and practice. McGraw-Hill, New York
Massart DL, Vandeginste BGM, Deming SN, Michotte, Y, Kaufman, F (1988) Chemometrics: a textbook. Elsevier, Amsterdam
Araujo PW, Brereton RG (1996) Trends Anal Chem 15:26
Araujo PW, Brereton RG (1996) Trends Anal Chem 15:63
Zougagh M, Rudner PC, de Torres AG, Pavon JMC (2000) J Anal At Spectrom 15:1589
Gázquez D, Sánchez-Viñas M, Bagur MG, Garcia G (1998) J Anal At Spectrom 13:105
Camino M, Bagur MG, Sánchez-Viñas M, Gázquez D, Romero R (2001) J Anal At Spectrom 16:638
Ferreira SLC, dos Santos HC, Fernandes MS, de Carvalho MS (2002) J Anal At Spectrom 17:115
Delacroix A, Porte C, (1996) Analusis 24:22
Bosque-Sendra JM, Nechar M, Cuadros Rodríguez L, Molina MF (1995) Anal Proc 32:375
Hu Y, Massart DL (1989) J Chromatogr 458:311
Melo MH, Ferreira SLC, Santelli RE (2000) Microchem J 65:59
de Jesus DS, Cassella RJ, Ferreira SLC, Costa ACS, de Carvalho MS, Santelli RE (1998) Anal Chim Acta 366:263
Lemos VA, Santelli RE, Carvalho MS, Ferreira SLC (2000) Spetrochimica Acta Part B 55:1497
Lemos VA, Ferreira SLC (2001) Anal Chim Acta 441:281
Ferreira SLC, dos Santos WNL, Lemos VA (2001) Anal Chim Acta 445:145
Fang Z, Xu Sk, Zhang SC (1987) Anal Chim Acta 200:35
Fang Z (1993) Flow injection separation and preconcentration. VCH Weinheim
Doehlert DH (1970) Appl Stat 19:231
Statistica for Windows (1999) StatSoft, Inc, Tulsa, USA
(2003) Anal Chim Acta (in press)
Analytical Methods Commitee (1994) Analyst 119:2363
Cuadros Rodríguez L, García Campaña AM, Bosque-Sendra JM (1996) Anal Lett 29:1231
IUPAC (1978) Analytical Chemistry Division, Spectrochim Acta B 33:242
Acknowledgements
The authors acknowledge grants from Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) and Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Ferreira, S.L.C., dos Santos, W.N.L., Bezerra, M.A. et al. Use of factorial design and Doehlert matrix for multivariate optimisation of an on-line preconcentration system for lead determination by flame atomic absorption spectrometry. Anal Bioanal Chem 375, 443–449 (2003). https://doi.org/10.1007/s00216-002-1695-y
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00216-002-1695-y