Experimental study on the early efficacy of excimer laser with adjunctive balloon angioplasty in dog’s femoral artery

  • Published:
Journal of Tongji Medical University Aims and scope Submit manuscript

Summary

The effect of domestically-manufactured excimer laser with adjunctive balloon angioplasty in achieving revascularization and reduction of residual stenosis was assessed. 20 femoral arteries with thrombosis and occlusion from 12 dogs were subject to angiography. At first excimer laser angioplasty was done followed by balloon angioplasty. The diameter and residual stenosis of revascularized vessel were measured. The result showed that 17 out of 20 vessels (85 %) were revascularized. The diameter of revascularized vessel by excimer laser were 1. 22 ±0. 14 mm, while residual stenoses were 54 %±5 %. After adjunctive balloon angioplasty the diameter and residual stenoses were 2. 04±0.16 mm and 20 %±7 % respectively (P< 0. 05 andP< 0. 01). Complication in form of vasoperforation occurred in 3/20 vessels(15%). It is concluded that Chinamanufactured excimer laser angioplasty is effective when used for revascularization. While the reduction of narrowing and residual stenoses was enhanced after adjunction of balloon angioplasty. This method can be employed in treating peripheral occlusive disease effectively and safely.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Forrester J S, Litvack F, Gruundest Wet al. The excimer laser current knowledge and future prospects. J Intervent Cardiol, 1988, 1: 75

    Article  Google Scholar 

  2. Savage M P, Goldberg S, Hirshfeld J Wet al. Clinical and angiographic determinants of primary coronary angioplasty success. JACC, 1991, 17: 22

    PubMed  CAS  Google Scholar 

  3. Meier B. Interventional Cardiology. NY: Hogrefe & Huber Publishers, 1990. 243–260

    Google Scholar 

  4. Lee G, Ikeda R M, Chen M Cet al. Limitation, Risks and Complication of laser recanalization: a cautious approach warranted. Am J Cardiol, 1985, 56: 181

    Article  PubMed  CAS  Google Scholar 

  5. Yu S, Wang D W, Hu X Jet al. Choice of lasers for laser angioplasty. J Tongji Med Univ, 1989, 9(3): 181

    PubMed  CAS  Google Scholar 

  6. Ben Shachar G, Spector M L, Morse D Eet al. Hazardous by — products of laser irradiation: a qualitation and quantitative study (abstract). Circulation, 1986, 7: 46A

    Google Scholar 

  7. Meier B. Interventional Cardiology. NY: Hogrefe & Huber Publishers, 1990. 261–266

    Google Scholar 

  8. Barbieri E, Perbellini A, Taddei Get al. Three years experience with thermal and excimer lasers in the treatment of peripheral artery disease. Lasers in Medical Science, 1991, 6: 297

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hesong, Z., Shu, Y., Huaiming, G. et al. Experimental study on the early efficacy of excimer laser with adjunctive balloon angioplasty in dog’s femoral artery. Journal of Tongji Medical University 16, 87–90 (1996). https://doi.org/10.1007/BF02887964

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02887964

Key words

Navigation