Summary

Capillaries with different inner diameters (50–250 μm) were packed with the same stationary phase and their electrochromatographic performance was studied. Special focus was put on the currents measured in these capillaries and the necessity of controlling temperature, especially in capillaries of larger inner diameter. With a commercial instrument no loss in plate numbers was observed for a capillary with an I.D. of 180 μm and the corresponding Ohm plot was linear.

A test mixture consisting of polar (weakly basic and acidic) and non-polar compounds was separated on packed capillaries with a range of inner diameters. No mass overloading could be observed if sample concentrations up to 5000 ppm were injected. On the other hand, when the injected sample volume exceeds 1% of the packed bed volume a decrease of the separation efficiency occurred.

When the capillary I.D. was changed from 50 μm to 180 μm, peak heights and peak areas increased 5 to 6-fold. As a consequence the detection limits of the 180 μm I.D. capillary were 5.6–7.5 times lower than those obtained in a 50 μm I.D. capillary.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Pretorius, V.; Hopkins, B.J.; Schieke, J.D.J. Chromatogr. 1974,99, 23.

    Article  CAS  Google Scholar 

  2. Knox, J.H.Chromatographia 1988,26, 329.

    Article  CAS  Google Scholar 

  3. Choudhary, G.; Horváth, Cs.J. Chromatogr. A 1997,781, 161.

    Article  CAS  Google Scholar 

  4. Wen, E.; Asiaie, R.; Horváth, Cs.J. Chromatogr. A 1999,855, 349.

    Article  CAS  Google Scholar 

  5. Knox, J.H.; Grant, I.H.Chromatographia 1991,32, 317.

    Article  CAS  Google Scholar 

  6. Knox, J.H.; McCormack, K.A.Chromatographia 1994,38, 207.

    Article  CAS  Google Scholar 

  7. Yamamoto, H.; Baumann, J.; Erni, F.J. Chromatogr. 1992,593, 313.

    Article  CAS  Google Scholar 

  8. Pusecker, K.; Schewitz, J.; Gfrörer, P.; Tseng, L.-H.; Albert, K.; Bayer, E.Anal. Chem. 1998,70, 3280.

    Article  CAS  Google Scholar 

  9. Yan, C.; Schaufelberger, D.; Erni, F.J. Chromatography A 1994,670, 15.

    Article  CAS  Google Scholar 

  10. Rebscher, H.; Pyell, U.Chromatographia 1996,42, 171.

    Article  CAS  Google Scholar 

  11. Chen, J.-R.; Zare, R.N.; Peters, E.C.; Svec, F.; Frechet, J.J.Anal. Chem. 2001,73, 1987.

    Article  CAS  Google Scholar 

  12. Bruin, G.J.M.; Stegeman, G.; van Asten, A.C.; Xu, X.; Kraak, J.C.; Poppe, H.J. Chromatogr. 1991,559, 163.

    Article  CAS  Google Scholar 

  13. Kok, W.Chromatographia 2000,51 (Supplement Vol.), 52.

    Google Scholar 

  14. Boughtflower, R.J.; Underwood, T.; Patterson, C.J.Chromatographia 1995;40, 329.

    Article  CAS  Google Scholar 

  15. Engelhardt, H.; Hafner, F.-T.Chromatographia 2000,52, 769.

    Article  CAS  Google Scholar 

  16. van den Bosch, S.E.; Heemstra, S.; Kraak, J.C.; Poppe, H.J. Chromatogr. A 1996,755, 165.

    Article  Google Scholar 

  17. Pyell, U.; Rebscher, H.; Banholczer, A.J. Chromatogr. A 1997,779, 155.

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Dedicated to Professor Dr. Heinz Engelhardt on the occasion of his 65th birthday.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Scherer, B., Steiner, F. Capillary electrochromatography (CEC) in columns with different inner diameters. Chromatographia 54, 155–162 (2001). https://doi.org/10.1007/BF02492236

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02492236

Key Words

Navigation