Combined use of detachable coil against persistent mechanical hemolysis after transcatheter occlusion using Rashkind umbrella device in adult patient with patent ductus arteriosus

  • Case reports
  • Published:
Heart and Vessels Aims and scope Submit manuscript

Summary

Mechanical hemolysis after transcatheter occlusion of the patent ductus arteriosus using the Rashkind umbrella device has been postulated as a rare, but serious complication, even necessitating surgical repair. A rare, case of an adult patient with massive hemolytic anemia, successfully controlled by the combined use of several detachable coil devices is reported. The use of coil devices might be considered as a therapeutic option in such cases.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Hosking MC, Benson LN, Musewe N, Dyck JD, Freedom RM (1991) Transcatheter occlusion of the persistently patent ductus arteriosus: 40-month follow-up and prevalence of residual shunting. Circulation 84:2313–2317

    PubMed  Google Scholar 

  2. Tynan M, Members of the European Registry Group (1992) Transcatheter occlusion of persistent arterial duct: Report of the European Registry. Lancet 340:1062–1066

    PubMed  Google Scholar 

  3. Mullins CE (1990) Interventional techniques for congenital heart disease. State of the Art Reviews. Cardiac surgery 4:375–395

    Google Scholar 

  4. Cambier PA, Kirby WC, Wortham DC, Moore JW (1992) Percutaneous closure of the small patent ductus arteriosus using coil embolization. Am J Cardiol 69:815–816

    PubMed  Google Scholar 

  5. Moore JW, George L, Kirkpatrick SE (1994) Closure of residual patent ductus arteriosus with occluding spring coil after implant of a Rashkind occluder. Am Heart J 127:943–945

    PubMed  Google Scholar 

  6. Hijazi ZM, Geggel RL, Al-Fadley F (1995) Transcatheter closure of the residual patent ductus arteriosus shunting after the Rashkind occluder device using single or multiple Gianturco coils. Cathet Cardiovasc Diagn 36:255–258

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Murakami, H., Tsuchihashi, K., Tomita, H. et al. Combined use of detachable coil against persistent mechanical hemolysis after transcatheter occlusion using Rashkind umbrella device in adult patient with patent ductus arteriosus. Heart Vessels 12, 49–51 (1997). https://doi.org/10.1007/BF01747502

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01747502

Key words

Navigation