Summary
In order to determine energy expenditure, the Douglas Bag technique (DB) and Kofranyi-Michaelis respirometers (KM) have been widely used under field conditions for several decades. Some years ago the Oxylog (OX) method was developed, measuring simultaneously the difference of partial oxygen pressure in inspired and expired air (PO2 diff.) by two polarographic oxygen sensors. In order to compare these three methods laboratory experiments (3 test subjects, 5 different bicycle ergometer work loads, 180 measurements per apparatus) were performed. Oxygen uptake (VO2) varied between about 0.9 to 3.01/min. The VO2data obtained by the DB method, which were used as a reference, and those obtained by the KM method agreed fairly well. The recorded data of OX underestimated VO2up to 21%, with the deviation increasing with work intensity. A sufficient accuracy of recorded VO2 was observed only up to moderate work intensity. OX data calculated from ventilation volume of inspired air per minute (V1) and PO2 diff., measured by OX, were always about 19% higher than those recorded by OX. This means that the calculated VO2 values of the OX corresponded fairly well with DB values at heavy work loads. The reason for the differences between recorded and calculated OX data is still unknown. Further research is urgently needed.
References
Ballal MA, Macdonald IA (1982) An evaluation of the oxylog as a portable device with which to measure oxygen consumption. Clin Phys Physiol Meas 3:57–65
Consolatio CF (1971) Energy expenditure studies in military populations using Kofranyi-Michaelis respirometers. Am J Clin Nutr 24:1431–1437
Harrison MH, Brown GA, Belyavin AJ (1982) The “Oxylog”: an evaluation. Ergonomics 25:809–820
Hermansen L, Vokac Z, Lereim P (1972) Respiratory and circulatory response to added air flow resistance during exercise. Ergonomics 15:15–24
Humphrey SJE, Wolff HS (1977) The oxylog. J Physiol 267: 12p
Ikegami Y, Hiruta S, Ikegami H, Miyamura M (1988) Development of a telemetry system for measuring oxygen uptake during sports activities. Eur J Appl Physiol 57:622–626
Louhevaara V, Ilmarinen J, Oja P (1985) Comparison of three field methods for measuring oxygen consumption. Ergonomics 28:463–470
Montoye HJ, van Huss WD, Reineke EP, Cockrell J (1958) An investigation of the Müller-Franz Calorimeter. Int Z Angew Physiol Einschl Arbeitsphysiol 17:28–33
Rutenfranz J, Seliger V, Andersen KL, Ilmarinen J, Flöring R, Rutenfranz M, Klimmer F (1977) Erfahrungen mit einem transportablen Gerät zur kontinuierlichen Registrierung der Herzfrequenz für Zeiten his zu 24 Stunden. Eur J Appl Physiol 36:171–185
Author information
Authors and Affiliations
Additional information
Deceased
Rights and permissions
About this article
Cite this article
Wenzel, C., Wenzel, H.G., Golka, K. et al. A comparative study on different methods for the determination of energy expenditure. Int Arch Occup Environ Health 62, 101–103 (1990). https://doi.org/10.1007/BF00397856
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00397856