Deep sclerectomy: results with and without collagen implant

  • Published:
International Ophthalmology Aims and scope Submit manuscript

Abstract

Purpose: To study the need, the safety and the success rate of collagen implant in eyes that underwent deep sclerectomy, a new non penetrating filtration procedure, we compared the results of deep sclerectomy with (DSCI) and without (DS) collagen implant. Methods: Of 168 patients (168 eyes) with various types of medically uncontrolled open angle glaucoma, 86 (86 eyes) underwent DSCI, and 82 (82 eyes) underwent DS. Visual acuity, slit lamp examination, intraocular pressure (IOP) measurements were performed before surgery and prospectively at days 1 and 7 and months, 1, 2, 3, 6, 9, 12, 15, 18, and 24 after surgery. Deep sclerectomy was performed according to Kozlov's original technique. The collagen implant drainage device was radially secured in the center of the deep sclerectomy dissection. Results: The mean follow-up period was 9.7 ± 6.5 months for DSCI, and 9.0 ± 4.8 months for DS. The mean preoperative IOP was 26.9 ± 8.8 mmHg for DSCI and 25.8 ± 8.5 mmHg for DS. The mean postoperative IOP and visual acuity were similar between the two groups. Complete and qualified success rates were better when the collagen implant was used (Log-Rank test: p = 0.0002 and 0.033 for complete and qualified success respectively). The need for postoperative glaucoma medications was significantly lower when the collagen implant was used (0.2 ± 0.5 versus 0.5 ± 0.7 medication per patient in the DSCI and DS respectively, Student's t test: p = 0.0038). There was significantly less bleb fibrosis when the collagen implant was used (2% and 11% in DSCI and DS respectively, p = 0.029). Conclusion: The collagen implant device is safe, increases the success rate of deep sclerectomy, and lowers the need for postoperative glaucoma medications.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Kozlov VI et al. Nonpenetrating deep sclerectomy with collagen. Ophthal Surg 1990; 3: 44–6.

    Google Scholar 

  2. Fyodorov SN, Koslov VI et al. Nonpenetrating deep sclerectomy in open angle glaucoma. Ophthal Surg 1990; 3: 52–5.

    Google Scholar 

  3. Zimmerman TJ, Kooner KS, Ford VJ et al. Effectiveness of nonpenetrating trabeculectomy in aphakic patients with glaucoma. Ophthal Surg 1984; 15: 44–9.

    Google Scholar 

  4. Zimmerman TJ, Kooner KS, Ford VJ et al. Trabeculectomy vs. nonpenetrating trabeculectomy: a retrospective study of two procedures in phakic patients with glaucoma. Ophthal Surg 1984; 15: 734–40.

    Google Scholar 

  5. Arenas E. Trabeculectomy ab externo. Highlights Ophthalmol Lett 1991; XIX: 9.

    Google Scholar 

  6. Gierek A, Szymanski A. Results of deep sclerectomy for open angle glaucoma. Folia Ophthalmol, Leipzig 1987; 12 (4): 227–9.

    Google Scholar 

  7. Tavano G, Chabin T, Barrut JM. Hémitrabéculectomie ab externo non invasive. Bull Soc Opht France 1993; 8–9 XCIII: 749–50.

    Google Scholar 

  8. Sickenberg M, Chiou AGY, Bigar F, Mermoud A. Deep sclerectomy with collagen implant: A new non-penetrating filtering study. Ophthalmology 1995; 102 (9A): 134.

    Google Scholar 

  9. Demailly P, Jeanteur-Lunel MN, Berkani M et al. Sclérectomie profonde non perforante associée à la pose d'un implant de collagène dans le glaucome primitif à angle ouvert. Ophtalmologie 1995; 9: 66–70.

    Google Scholar 

  10. Watson P, Jakeman C. The complications of trabeculectomy (a 20-year follow-up). Eye 1990; 4: 425–38.

    Google Scholar 

  11. Kao SF, Lichter PR, Musch DC. Anterior chamber depth following filtration surgery. Ophthal Surg 1989; 20: 332.

    Google Scholar 

  12. Stewart WC, Shields MB. Management of anterior chamber depth after trabeculectomy. Am J Ophthalmol 1988; 106: 41.

    Google Scholar 

  13. Brubaker RF, Pederson JE. Ciliochoroidal detachment. Surv Ophthal 1983; 27: 281.

    Google Scholar 

  14. Gressel MG, Parrish RK, Heuer DK. Delayed nonexpulsive suprachoroidal hemorrhage. Arch Ophthalmol 1984; 102: 1757.

    Google Scholar 

  15. Ruderman JM, Harbin TS Jr, Campbell DG. Postoperative suprachoroidal hemorrhage following filtration procedures. Arch Ophthalmol 1986; 104: 201.

    Google Scholar 

  16. Freedman J, Gupta M, Bunke A. Endophthalmitis after trabeculectomy. Arch Ophthalmol 1978; 6: 1017.

    Google Scholar 

  17. Chiou AGY, Mermoud A, Hédiguer SEA, Schnyder CC, Faggioni R. Ultrasound biomicroscopy of eyes undergoing deep sclerectomy with collagen implant using an ultrasound biomicroscope. Br J Ophthalmol 1996; 80; 541–544.

    Google Scholar 

  18. Mermoud A, Faggioni R, Schnyder CC, Sickenberg M, Chiou AGY, Hédiguer SEA, Sanchez E. Nd-Yag goniopuncture after deep sclerectomy with collagen implant. Invest Ophthalmol Vis Sci 1996; 37 (3): 1167.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Sanchez, E., Schnyder, C.C., Sickenberg, M. et al. Deep sclerectomy: results with and without collagen implant. Int Ophthalmol 20, 157–162 (1996). https://doi.org/10.1007/BF00212963

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00212963

Key words

Navigation