Dosimetry of small electron fields shaped by lead

  • Technical Report
  • Published:
Australasian Physics & Engineering Sciences in Medicine Aims and scope Submit manuscript

Abstract

Electron radiotherapy fields are commonly used to treat superficial cancers. Field shaping can be achieved by placing lead on the patient surface to minimise the dose to surrounding areas. However, significant dosimetry changes under high density material edges for electron fields have been reported in the literature. This project evaluated the dosimetry of small dimension electron fields shaped with lead placed on the surface. Comparisons were made between circular lead cutouts placed on the skin and low melting point alloy cutouts placed in an applicator. Depth doses, profiles and output factors were measured using a diode detector in a water phantom. Film was also used to determine surface dose delivered when the lead cutouts were placed on the surface. Minimal differences were observed between the different setups for the depth dose curves, although significant differences were seen in the penumbra and the surface doses. The penumbra is smaller for the lead cutouts placed on the surface, however, significant dose increases at the edge of the field were observed for larger fields and energies; this may result in undesirable clinical effects.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Verhaegen, F., Buffa, F. M., Deehan, C.,Quantifying effects of lead shielding in electron beams: a Monte Carlo study, Phys. Med. Biol. 46, 757–69, 2001.

    Article  CAS  PubMed  Google Scholar 

  2. Pohlit, W., Manegold, K. H., inHigh energy photons and electrons S. Kramer, N. Suntharalingam, G. F. Zinninger, Eds. (Wiley, New York, 1976) pp. 243.

    Google Scholar 

  3. Sharma, S. C., Wilson, D. L., Jose, B.,Dosimetry of small fields for Therac 20 electron beams, Med. Phys. 11, 697–702, 1984.

    Article  CAS  PubMed  Google Scholar 

  4. Nair, R. P., Nair, T. K., Wrede, D. E.,Shaped field electron dosimetry for a Philips SL75/10 linear accelerator, Med. Phys. 10, 356–60, 1983.

    Article  CAS  PubMed  Google Scholar 

  5. Rustgi, S. N., Working, K. R.,Dosimetry of small field electron beams, Med. Dosim. 17, 107–10, 1992.

    CAS  PubMed  Google Scholar 

  6. Kapur, A., Ma, C. M., Mok, E. C., Findley, D. O., Boyer, A. L.,Monte Carlo calculations of electron beam output factors for a medical linear accelerator, Phys. Med. Biol. 43, 3479–94, 1998.

    Article  CAS  PubMed  Google Scholar 

  7. Verhaegen, F., Mubata, C., Pettingell, J., Bidmead, A. M., Rosenberg, I., Mockridge, D., Nahum, A. E.,Monte Carlo calculation of output factors for circular, rectangular, and square fields of electron accelerators (6–20 MeV), Med. Phys. 28, 938–49, 2001.

    Article  CAS  PubMed  Google Scholar 

  8. Zhang, G. G., Rogers, D. W., Cygler, J. E., Mackie, T. R.,Monte Carlo investigation of electron beam output factors versus size of square cutout, Med. Phys. 26, 743–50, 1999.

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to M. D. Perez.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Perez, M.D., Hill, R.F., Whitaker, M.K. et al. Dosimetry of small electron fields shaped by lead. Australas. Phys. Eng. Sci. Med. 26, 119–124 (2003). https://doi.org/10.1007/BF03178781

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF03178781

Key words

Navigation