Abstract
The γ-ray spectrum of241Am was reinvestigated by using intense sources. A purified solution source was used to make sure that the γ-lines presents in the spectrum come from the α-decay of241Am. The γ-spectrometer consists of 40% relative efficiency HPGe detector and 8192-channel ADC. Out of 137 γ-lines that are presents in the spectrum 46 are new.
References
Michaelis, Z. Phys. 194 (1966) 395.
C. M. Lederer, J. K. Poggenburg, F. Asaro, J. O. Rasmussen, I. Perlman, Nucl. Phys., 84 (1966) 481.
A. Genoux-Lubain, G. Ardisson, Radiochem. Radioanal. Letters, 33 (1978) 59.
A. Genoux-Lubain, G. Ardisson, C. R. Acad. Sci. Paris, 287B (1978) 13.
C. Ardisson, A. Genoux-Lubain, V. Barci, G. Ardisson, Radiochem. Radioanal. Letters 40 (1979) 207.
J. Stanicek, P. Povinec, Acta Phys. Univ. Comen, 28 (1987) 91.
S. U. El-Kameesy, Acta Phys. Hung., 71 (1992) 15.
Y. A. Ellis-Akovali, N. D. S. A=237. 74, 461 (1995), p. 493.
E. Browne, R. B. Firestone, Table of Radioactive Isotopes,V. S. Shirly (Ed.), 1996, p. 237–1.
E. Browne, R. B. Firestone, Table of Radioactive Isotopes,V. S. Shirly (Ed.), 1986, p. 233–3.
E. Browne, R. B. Firestone, Table of Radioactive Isotopes,V. S. Shirly (Ed.), 1986, p. 233–2.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Abdul-Hadi, A. Gamma-spectrum of241Am. J Radioanal Nucl Chem 231, 147–152 (1998). https://doi.org/10.1007/BF02388022