Skip to main content
Log in

Mechanical behavior of pressurized in vitro prearteriolar vessels determined with a video system

  • Mechanical Behavior of Vascular Smooth Muscle Papers Presented at a Biomedical Engineering Society Symposium, April 14, 1983, Chicago, Illinois
  • Published:
Annals of Biomedical Engineering Aims and scope Submit manuscript

Abstract

The muscular resistance arteries of the mesentery and brain serve two different control functions in the cardiovascular system. The former are representative vessels of vascular beds that influence total peripheral resistance and blood pressure; the latter are a good model of vessels in beds that demonstrate blood flow autoregulation. Our purpose was to develop a versatile myographic system appropriate for the in vitro study of 75–250 μm diameter vessels and to explore different physiological properties of cerebral and mesenteric arteries. In this paper the system is described in detail, examples of its use in determining the dynamic responses of the vessels to electrical stimulation are provided, and certain measures indicative of the extent of myogenic behavior are characterized.

Cylindrical artery segments about 3-mm long were dissected from Wistar-Kyoto rats and mounted in a chamber filled with physiological saline solution maintained at 37°C. The same solution was perfused via a syringe into one end of the vessel through a microcannula. The other end was then occluded so that experiments could be made over a wide range of transmural pressures without flow. The vessel was viewed through a microscope coupled with a TV camera, and the video output signal of a selected scan line was processed by an electronic dimension analyzing system. This permitted simultaneous digital presentation and analog voltage outputs of the vessel wall thicknesses and lumen diameter. We further incorporated servo control of the syringe using a motor drive. In this way, vessel tests could be carried out at constant pressure or constant diameter, and vessel responses could be obtained following either pressure or diameter command signals.

Using the methods presented in this study, small vessels can be maintained under conditions that approximate their in vivo state more closely than other in vitro techniques using ring segments on wires. We also find that the opto-electronic instrumentation is ideally suited for studying the dynamic vessel properties that underlie the control of vascular smooth muscle.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Assmann, R. and H. Henrich. A video-angiometer for simultaneous and continuous measurement of inner and outer vessel diameters.Pflügers Arch. 376:263–266, 1978.

    Article  CAS  PubMed  Google Scholar 

  2. Auer, L. A method for continuous monitoring of pial vessel diameter changes and its value for dynamic studies of the regulation of cerebral circulation. A preliminary report.Pflügers Arch. 373:195–198, 1978.

    Article  Google Scholar 

  3. Baez, S. Recording of microvascular dimensions with an imagesplitter television microscope.J. Appl. Physiol. 21:299–301, 1966.

    CAS  PubMed  Google Scholar 

  4. Bevan, J.A. and J.V. Osher, A direct method for recording tension changes in the wall of small blood vessels in vitro.Agents Actions. 2:257–260, 1972.

    Article  CAS  PubMed  Google Scholar 

  5. Brayden, J.E., W. Halpern, and L.R. Brann. Biochemical and mechanical properties of resistance arteries from normotensive and hypertensive rats.Hypertension. 5:17–25, 1983.

    CAS  PubMed  Google Scholar 

  6. Gotoh, F., F. Muramatsu, Y. Fukuuchi, H. Okaysu, K. Tanaka, N. Suzuki, and M. Kobari. Video camera method for simultaneous measurement of blood flow velocity and pial vessel diameter.J. Cereb. Blood Flow Metab. 2:421–428, 1982.

    CAS  PubMed  Google Scholar 

  7. Halpern, W., S.A. Mongeon, and D.T. Root. Stress, tension and myogenic aspects of small isolated extraparenchymal rat arteries. InSmooth Muscle Contraction, edited by N.L. Stephens. New York: Dekker, 1984, pp. 427–456.

    Google Scholar 

  8. Halpern, W., M.J. Mulvany, and D.M. Warshaw. Mechanical properties of smooth muscle cells in the walls of arterial resistance vessels.J. Physiol. 275:85–101, 1978.

    CAS  PubMed  Google Scholar 

  9. Heistad, D.D. Effects of nerves on cerebral vessels in stroke, cerebral edema, and hypertension.J. Lab. Clin. Med. 99:139–147, 1982.

    CAS  PubMed  Google Scholar 

  10. Intaglietta, M., N.R. Silverman, and W.R. Tompkins. Capillary flow velocity measurements in vivo and in situ by television methods.Microvasc. Res. 10:165–179, 1975.

    Article  CAS  PubMed  Google Scholar 

  11. Intaglietta, M. and W.R. Tompkins. On-line measurement of microvascular dimensions by television microscopy.J. Appl. Physiol. 32:546–551, 1972.

    CAS  PubMed  Google Scholar 

  12. Johnson, P.C. Measurement of microvascular dimensions in vivo.J. Appl. Physiol. 23:593–596, 1967.

    CAS  PubMed  Google Scholar 

  13. Johnson, P.C. The myogenic response. InHandbook of Physiology, Sect. 2, Vol. II. The Cardiovascular System, edited by D.F. Bohr, A.P. Somlyo, and H.V. Sparks, Jr. Bethesda, Maryland: American Physiological Society, 1980, pp. 409–442.

    Google Scholar 

  14. Kontos, H.A., E.P. Wei, R.M. Navari, J.E. Levasseur, W.I. Rosenblum, and J.L. Patterson, Jr. Responses of cerebral arteries and arterioles to acute hypotension and hypertension.Am. J. Physiol. 234:H371-H383, 1978.

    CAS  PubMed  Google Scholar 

  15. Milnor, W.R.Hemodynamics. Baltimore Maryland: Williams and Wilkins, 1982, pp. 60–61.

    Google Scholar 

  16. Mulvany, M.J. and W. Halpern. Mechanical properties of vascular smooth muscle cells in situ.Nature. 260:617–619, 1976.

    Article  CAS  PubMed  Google Scholar 

  17. Norris, C.P., G.E. Barnes, E.E. Smith, and H.J. Granger. Autoregulation of superior mesenteric flow in fasted and fed dogs.Am. J. Physiol. 237:H174-H177, 1979.

    CAS  PubMed  Google Scholar 

  18. Schabert, A., R.D. Bauer, and R. Busse. Photoelectric device for the recording of diameter changes of opaque and transparent blood vessels in vitro.Pflügers Arch. 385:239–242, 1980.

    Article  CAS  PubMed  Google Scholar 

  19. Shepherd, J.T. and P.M. Vanhoutte.The Human Cardiovascular System. New York: Raven Press, 1979, pp. 7–8.

    Google Scholar 

  20. Warshaw, D.M., M.J. Mulvany, and W. Halpern. Mechanical and morphological properties of arterial resistance vessels in young and old spontaneously hypertensive rats.Circ. Res. 45:250–259, 1979.

    CAS  PubMed  Google Scholar 

  21. Wiederhielm, C.A. Continuous recording of arteriolar dimensions with a television microscope.J. Appl. Physiol. 18:1041–1042, 1963.

    CAS  PubMed  Google Scholar 

  22. Wiederhielm, C.A., J.W. Woodbury, S. Kirk, and R.F. Rushmer. Pulsatile pressures in the microcirculation of the frog mesentery.Am. J. Physiol. 207:173–176, 1964.

    CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Halpern, W., Osol, G. & Coy, G.S. Mechanical behavior of pressurized in vitro prearteriolar vessels determined with a video system. Ann Biomed Eng 12, 463–479 (1984). https://doi.org/10.1007/BF02363917

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02363917

Keywords

Navigation