Summary
Sensitive and selective detection of dansylhydrazones of atmospheric carbonyl compounds (aldehydes and ketones) can be achieved using high performance liquid chromatography (HPLC) with fluorescence or chemiluminescence detection. The carbonyl compounds are derivatized by drawing air through small glass cartridges packed with porous glass particles impregnated with dansylhydrazine. After sampling, the contents of the cartridges are analyzed on-line by using a small plug of water (200 μL) to transfer and focus the hydrazone derivatives at the head of a HPLC column. Greatly increased sensitivity over traditional methods derives from 1) analysis of the entire contents of the sampling cartridge, and 2) detection by fluoresence or peroxyoxalate chemilum-inescence. Results are compared for photo-initiated and H2O2-initiated peroxyoxalate chemiluminescence. This novel and practical system enables the detection of sub-ppbv concentrations of formaldehyde, acetaldehyde, acetone and higher carbonyls in air using relatively short sampling times.
Similar content being viewed by others
References
Board on Toxicology and Environmental Health Hazards, National Research Council, Formaldehyde and Other Aldehydes, National Academy Press, Washington, D.C., 1981.
D. Grosjean, Environ. Sci. Technol.,16, 254 (1982).
R. L. Tanner, A. H. Miguel, J. B. de Andrade, J. S. Gaffney, G. E. Streit, Environ. Sci. Technol.,22, 1026 (1988).
R. Otson, P. Fellin, Sci. Total Environ.,77, 95 (1988).
D. Grosjean, K. Fung, Anal. Chem.,54, 1221 (1982).
K. Kuwata, M. Uebori, H. Yamasaki, Y. Kuge, Y. Kiso, Anal. Chem.,55, 2013 (1983).
F. Lipari, S. J. Swarin, Environ. Sci. Technol.,19, 70 (1985).
R. R. Arnts, S. B. Tejada, Environ. Sci. Technol.,23, 1428 (1989).
R. M. Riggin, Compendium of methods for the determination of toxic organic compounds in ambient air, U.S. Environmental Protection Agency Report EPA-600/4-84-041, Research Triangle Park, N.C., 1984.
M. Possanzini, P. Ciccioli, V. Di Palo, R. Draisci, Chromatographia,23, 829 (1987).
H.-J. Gotze, S. Harke, Fresenius Z. Anal. Chem.,335, 286 (1989).
M. C. Facchini, G. Chiavari, S. Fuzzi, Chemosphere,15, 667 (1986).
A. Gromping, K. Cammann, Fresenius Z. Anal. Chem.,335, 796 (1989).
M. Igawa, J. W. Munger, M. R. Hoffmann Environ. Sci. Technol.,23, 556 (1989).
W. Schmied, M. Prewosnik, K. Bachmann, Fresenius Z. Anal. Chem.,335, 464 (1989).
C. M. Druzik, D. Grosjean, A. Van Neste, S. S. Parmar, Int. J. Environ. Anal. Chem.,38, 495 (1990).
E. A. Chandross, Tetrahedron Lett., 761 (1963).
M. M. Rauhut, L. J. Bollyky, B. G. Roberts, M. Loy, R. H. Whitman, A. Ianotta, A. M. Semsel, R. A. Clark J. Am. Chem. Soc.,89, 6515 (1967).
M. M. Rauhut, Acc. Chem. Res.,2, 80 (1969).
R. S. Givens, R. L. Schowen, In Chemiluminescence and Photochemical Reaction Detection in Chromatography;J. W. Birks, Ed.; VCH Publishers: New York, 1989; pp. 125–147.
G. B. Schuster, Acc. Chem. Res.,12, 336 (1979).
F. McCapra K. Perring, R. J. Hart, R. A. Hann, Tetrahedron Lett., 5087 (1981).
C. L. R. Catherall T. F. Palmer, R. B. Cundall, J. Chem. Soc., Faraday Trans. 2,80, 823 (1984).
M. Orlovic, R. L. Schowen, R. S. Givens, F. Alvarez, B. Matuszewski, N. Parekh, J. Org. Chem.,54, 3606 (1989).
T. A. Nieman, In Chemiluminescence and Photochemical Reaction Detection in Chromatography;J. W. Birks, Ed.; VCH Publishers: New York, 1989; pp. 99–147.
R. E. Milofsky, J. W. Birks, Anal. Chem.,62, 1050 (1990).
K. W. Sigvardson, J. M. Kennish, J. W. Birks, Anal. Chem.,56, 1096 (1984).
S. Kobayashi, K. Imai, Anal. Chem.,52, 424 (1980).
J. W. F. Nielen, R. W. Frei, U. A. Th. Brinkman, In Selective Sample Handling in High-Performance Liquid Chromatography, Part A,R. W. Frei, K. Zech, Eds., Journal of Chromatography Library, Vol. 39A, Elsevier, Amsterdam, 1988; Chapter 1.
P. A. S. Smith, Derivatives of Hydrazine and Other Hydronitrogens Having N-N Bonds, Benjamin/Cummings Publ. Co., Reading, Massachusetts, 1983; Chapters 1–3.
K. Mopper, L. Johnson, J. Chromatogr.,256, 27 (1983).
L. Nondek, V. Chvalovsky, J. Chromatogr.,268, 395 (1983).
L. Nondek, V. Chvalovsky, J. Chromatogr.,312, 303 (1984).
J. J. Kirkland, W. W. Yau, H. J. Stoklosa, C. H. Dilks, J. Chrom. Sci.,15, 303 (1977).
C. F. Poole, S. A. Schuette, Contemporary Practice of Chromatography, Elsevier, Amsterdam, 1984; Section. 5.7.5.
R. E. Milofsky, Kinetics, Mechanism and Application of Photointiated Peroxyoxalate Chemiluminescence, Ph.D. Thesis, University of Colorado, Boulder, Colorado, 1991.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Nondek, L., Milofsky, R.E. & Birks, J.W. Determination of carbonyl compounds in air by HPLC using on-line analyzed microcartridges, fluorescence and chemiluminescence detection. Chromatographia 32, 33–39 (1991). https://doi.org/10.1007/BF02262463