Abstract
The construction and general performance characteristics of two PVC membrane sensors responsive to the amprolium (AmpH2+) cation are described. These sensors are based on the ion-associates amprolium-tetraphenylborate (AmpH-TPB) and amprolium-reineckate (AmpH-Rk). The electrodes exhibit near-Nernstian response for the doubly charged amprolium cation over the concentration ranges 0.1–100 and 0.01–100 mM for AmpH-TPB and AmpH-Rk, respectively. The pH does not affect electrode performance within the range 7.0–11.0. No interferences are caused by many inorganic cations, sugars and amino acids. The isothermal coefficients are found to be 0.0001306 and 0.0010438 V/ °C for AmpH-TPB and AmpH-Rk, respectively. Potentiometric titration and standard addition methods were used to determine amprolium in pure solutions and in veterinary soluble powder, with high accuracy and precision.
Similar content being viewed by others
References
J. E. F. Reynolds (ed.),Martindale, the Extra Pharmacopoeia, The Pharmaceutical Press, London, 1993, p. 510.
R. Malisch,Dtsch. Lebensm.-Rundsch. 1988,84, 282.
E. J. Kentzer, L. S. Cottingham, R. L. Smallidge,J. Assoc. Off. Anal. Chem. 1988,71, 251.
W. Van Leeuwen, H. W. Van Gend,Z. Lebensm.-Unters.-Forsch. 1988,186, 500.
J. T. Vanderslice, M. H. A. Huang,J. Assoc. Off. Anal. Chem. 1987,70, 920.
Y. Fukumoto, S. Shimada,Chikusan. No Kenkyu 1987,41, 1255.
T. Nagata, M. Saeki,J. Assoc. Off. Anal. Chem. 1986,69, 941.
R. Gauch, U. Leuenberger, U. Mueller,Dtsch. Lebensm.-Rundsch. 1986,82, 182.
A. Hobson-Frohock,J. Assoc. Public Anal. 1985,23, 83.
G. B. Cox, K. Sugden,Analyst 1976,101, 738.
N. Nose, Y. Hoshino, Y. Kikuchi, S. Kawauchi, ShokuhinEiseigaku Zasshi 1982,23, 176.
M. Patz, H-P. Thier, H. Vogt,Z. Lebensm.-Unters. Forsch. 1980,170, 329.
P. W. Hammond, R. E. Weston,Analyst 1969,94, 921.
J. Hrdlicka, J. Stolejda,Biol. Chem. Vet. 1978,14, 233.
M. Severijnen, A. M. G. Buyzen-Satijn, F. G. Buizer,Analyst 1975,100, 328.
E. P. Schulz, C. R. Szalkowski,Anal. Chem. 1961,33, 795.
C. R. Szalkowski, E. P. Schulz,J. Assoc. Off. Agric. Chem. 1961,44, 5.
A. F. Shoukry, M. S. Rizk, Y. M. Issa, E. M. Atia,Mikrochim. Acta,1997,127, 269.
I. C. Cohen, S. Crisp, J. Norcup,Analyst 1972,97, 254.
J. Kanora, C. R. Szalkowski,J. Assoc. Off. Agric. Chem. 1964,47, 209.
H. Krepska, R. Pakula,Chem. Anal. (Warsaw) 1967,12, 293.
Y. M. Issa, A. F. Shoukry, M. S. Rizk, E. M. Atia,J. Chem. Tech. Biotechnol. 1995,64, 379.
S. S. Badawy, A. F. Shoukry, Y. M. Issa,Analyst 1986,111, 1363.
D. G. Peter, J. M. Hayes, G. M. Hieftje,Chemical Separation and Measurements, Saunders, Philadelphia, 1974.
S. Dowdy, S. Wearden,Statistics for Research, Wiley, New York, 1983.
United State Pharmacopoeia, XXII, U. S. Pharmacopeial Convention, Md, 1995, p. 113.
L. I. Antropov,Theoretical Electrochemistry, Mir, Moscow, 1972.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Issa, Y.M., Rizk, M.S., Shoukry, A.F. et al. Plastic membrane electrodes for amprolium. Mikrochim Acta 129, 195–200 (1998). https://doi.org/10.1007/BF01244741
Received:
Revised:
Issue Date:
DOI: https://doi.org/10.1007/BF01244741